3 Framing and Clearances

Note:

Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design preference.

A.Selecting Appliance Location

When selecting a location for your appliance it is important to consider the required clearances to walls (see figure 3.1).

WARNING

Fire Risk

Provide adequate clearance:

Around air openings

To combustibles

• For service access

Locate appliance away from traffic areas.

Note: For actual appliance dimensions refer to Sec- tion 16.

A

0

B

In addition to these framing dimensions, also reference the following sections:

Clearances and Mantel Projections (Sections 3.C and 3.D)

Vent Clearances and Framing (Section 6).

C

D

Model

A

B

C

D

Cyclone-Cust

Inches

17

17

17

17

 

 

 

 

 

Millimeters

432

432

432

432

 

Figure 3.1 Appliance Locations

Heat & Glo • Cyclone-Cust2061-900 Rev. L • 10/08

7

Image 7
Contents What to do if you smell gas Model Cyclone-CustHot glass will cause burns Homeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsTools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsSelecting Appliance Location Framing and ClearancesModel Clearances Constructing the Appliance ChaseClearances to Combustibles Inches +0 to -1/2 Mantel Projections34-3/8 41-3/8Vent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Measuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsVT Min HT Max Vent DiagramsTop Vent Horizontal Termination One Elbow Two ElbowsTop Vent Horizontal Termination Three Elbows Flue Restrictor Top Vent Vertical Termination No ElbowTop Vent Vertical Termination Three Elbows Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Securing and Leveling the Appliance Appliance PreparationAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections DVP Series Venting OnlyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Roof Pitch Min. Ft Installing Roof Flashing and Vertical Ter- mination Cap18 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarGas Connection Gas InformationFuel Conversions Gas PressuresHigh Altitude Installations Electrical Information Recommendation for WireHot Surface Ignition Wiring Connecting to the ApplianceOptional Accessories Requirements Facing Material FinishingGlass Assembly Installation Appliance SetupClean the Appliance AccessoriesBefore Lighting Appliance Operating InstructionsLighting Appliance HSI Ignition Turn off all electric power to the applianceFinal inspection by Initial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Maintaining and Servicing Appliance Fan Motor ServiceHeat & Glo Cyclone-Cust 2061-900 Rev. L 10/08 Inspect Maintenance Tasks Maintenance TasksReference Materials Appliance Dimension DiagramLocation Inches Millimeter DVP vent components Vent Components DiagramsDVP vent components DVP-HSM-B Stocked Service PartsAt Depot Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

Cyclone-Cust specifications

Hearth and Home Technologies has made significant strides in the realm of home heating with its innovative Cyclone-Cust fireplace technology. Designed for modern living spaces, the Cyclone-Cust combines efficiency, aesthetics, and advanced features, making it a popular choice among homeowners seeking both style and functionality.

One of the standout features of the Cyclone-Cust is its unique combustion system. This fireplace employs a patented cyclone burn technology that ensures a more complete and efficient burn of wood or gas fuels. As a result, it produces less smoke and harmful emissions, making it an environmentally friendly option. The advanced combustion technology also contributes to increased heat output, allowing users to enjoy a warm and cozy environment without the need for excessive fuel consumption.

The Cyclone-Cust is engineered with user convenience in mind. Its intuitive control panel allows homeowners to regulate heat output and flame intensity effortlessly. The fireplace can be operated remotely, providing a modern touch that enhances user convenience. Additionally, the unit is equipped with smart technology that can integrate seamlessly with home automation systems. This feature allows users to monitor and control their fireplace from their smartphone or tablet, adding an extra layer of convenience.

Aesthetically, the Cyclone-Cust does not disappoint. It is available in various designs and finishes, allowing homeowners to select an option that complements their interior decor. The striking flame pattern creates a captivating visual experience, serving as a focal point in any living space. Whether you prefer a traditional look or a contemporary style, the Cyclone-Cust can be customized to suit your taste.

Safety is another key characteristic of Hearth and Home Technologies’ Cyclone-Cust fireplaces. The unit is designed with multiple safety features, including glass doors to prevent the accidental escape of sparks and embers. The built-in air wash system helps keep the glass clean, ensuring an unobstructed view of the flames while enhancing safety for families with children or pets.

In summary, the Hearth and Home Technologies Cyclone-Cust fireplace merges efficiency, convenience, safety, and aesthetic appeal into a single unit. Its advanced combustion technology, user-friendly controls, and customizable designs make it a standout option for those looking to enhance their home heating experience. With the Cyclone-Cust, homeowners can enjoy a sophisticated source of warmth that aligns with modern lifestyle demands and environmental considerations.