Hearth and Home Technologies Cyclone-Cust After Appliance is Lit, Frequently Asked Questions

Page 34

C. After Appliance is Lit

Initial Break-in Procedure

When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours to fully drive off any odor from paint and lubricants used in the manufacturing process. Condensation of the glass is normal.

Note: The appliance should be run three to four hours on the initial start-up. Turn it off and let it cool completely. Remove and clean the glass. Replace the glass and run the appliance for an additional 12 hours. This will help to cure the products used in the paint and logs.

During this break-in period it is recommended that some windows in the house be opened for air circulation. This will help avoid setting off smoke detectors, and help eliminate any odors associated with the appliance’s initial burning.

WARNING

Fire Risk.

High Temperatures.

Keep combustible household items away from appliance.

Do NOT obstruct combustion and ventilation air.

Do NOT place combustible items on top of or in front of appliance.

Keep furniture, draperies away from appliance.

CAUTION

Prevent accidental appliance operation when not attended.

Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time.

Property damage possible from elevated temperatures.

CAUTION

Smoke and odors released during initial operation.

Open windows for air circulation.

Leave room during initial operation.

Smoke may set off smoke detectors.

Smoke and odors may be irritating to sensitive individuals.

WARNING

Fire Hazard.

Keep combustible materials, gasoline and other flammable vapors and liquids clear of appliance.

Do NOT store flammable materials in the appliance’s vicinity.

• Do NOT use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids in this appliance.

• Combustible materials may ignite.

D. Frequently Asked Questions

ISSUE

SOLUTIONS

 

 

Condensation on the glass

This is a result of gas combustion and temperature variations. As the appliance warms, this

condensation will disappear.

 

 

 

Blue flames

This is a result of normal operation and the flames will begin to yellow as the appliance is al-

lowed to burn for 8 to 5 minutes.

 

 

 

 

When first operated, this appliance may release an odor for the first several hours. This is

Odor from appliance

caused by the curing of the paint and the burning off of any oils remaining from manufactur-

ing. Odor may also be released from finishing materials and adhesives used around the

 

 

appliance.

 

 

Film on the glass

The glass cylinder can be cleaned with standard household glass cleaner. See glass assem-

 

bly installation section for removal information.

 

 

 

Noise is caused by metal expanding and contracting as it heats up and cools down, similar to

Metallic noise

the sound produced by a furnace or heating duct. This noise does not affect the operation or

 

longevity of the fireplace.

 

 

34

Heat & Glo • Cyclone-Cust2061-900 Rev. L • 10/08

Image 34
Contents What to do if you smell gas Model Cyclone-CustHot glass will cause burns Congratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsInspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededSelecting Appliance Location Framing and ClearancesModel Clearances Constructing the Appliance ChaseClearances to Combustibles Inches 41-3/8 Mantel Projections34-3/8 +0 to -1/2Vent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Use of Elbows Vent Information and DiagramsVent Table Key Measuring StandardsTwo Elbows Vent DiagramsTop Vent Horizontal Termination One Elbow VT Min HT MaxTop Vent Horizontal Termination Three Elbows Top Vent Vertical Termination No Elbow Flue RestrictorTop Vent Vertical Termination Three Elbows Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstalling Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Appliance Preparation Securing and Leveling the ApplianceDVP Series Venting Only Installing Vent PipeAssembly of Vent Sections Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Installing Roof Flashing and Vertical Ter- mination Cap Roof Pitch Min. FtAssembling and Installing Storm Collar 18 Assembling the Storm Collar Around the PipeGas Pressures Gas InformationFuel Conversions Gas ConnectionHigh Altitude Installations Recommendation for Wire Electrical InformationHot Surface Ignition Wiring Connecting to the ApplianceOptional Accessories Requirements Finishing Facing MaterialAccessories Appliance SetupClean the Appliance Glass Assembly InstallationOperating Instructions Before Lighting ApplianceLighting Appliance HSI Ignition Turn off all electric power to the applianceFinal inspection by Initial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Fan Motor Service Maintaining and Servicing ApplianceHeat & Glo Cyclone-Cust 2061-900 Rev. L 10/08 Maintenance Tasks Inspect Maintenance TasksReference Materials Appliance Dimension DiagramLocation Inches Millimeter Vent Components Diagrams DVP vent componentsDVP vent components DVP-HSM-B Stocked Service PartsAt Depot Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

Cyclone-Cust specifications

Hearth and Home Technologies has made significant strides in the realm of home heating with its innovative Cyclone-Cust fireplace technology. Designed for modern living spaces, the Cyclone-Cust combines efficiency, aesthetics, and advanced features, making it a popular choice among homeowners seeking both style and functionality.

One of the standout features of the Cyclone-Cust is its unique combustion system. This fireplace employs a patented cyclone burn technology that ensures a more complete and efficient burn of wood or gas fuels. As a result, it produces less smoke and harmful emissions, making it an environmentally friendly option. The advanced combustion technology also contributes to increased heat output, allowing users to enjoy a warm and cozy environment without the need for excessive fuel consumption.

The Cyclone-Cust is engineered with user convenience in mind. Its intuitive control panel allows homeowners to regulate heat output and flame intensity effortlessly. The fireplace can be operated remotely, providing a modern touch that enhances user convenience. Additionally, the unit is equipped with smart technology that can integrate seamlessly with home automation systems. This feature allows users to monitor and control their fireplace from their smartphone or tablet, adding an extra layer of convenience.

Aesthetically, the Cyclone-Cust does not disappoint. It is available in various designs and finishes, allowing homeowners to select an option that complements their interior decor. The striking flame pattern creates a captivating visual experience, serving as a focal point in any living space. Whether you prefer a traditional look or a contemporary style, the Cyclone-Cust can be customized to suit your taste.

Safety is another key characteristic of Hearth and Home Technologies’ Cyclone-Cust fireplaces. The unit is designed with multiple safety features, including glass doors to prevent the accidental escape of sparks and embers. The built-in air wash system helps keep the glass clean, ensuring an unobstructed view of the flames while enhancing safety for families with children or pets.

In summary, the Hearth and Home Technologies Cyclone-Cust fireplace merges efficiency, convenience, safety, and aesthetic appeal into a single unit. Its advanced combustion technology, user-friendly controls, and customizable designs make it a standout option for those looking to enhance their home heating experience. With the Cyclone-Cust, homeowners can enjoy a sophisticated source of warmth that aligns with modern lifestyle demands and environmental considerations.