Hearth and Home Technologies Cyclone-Cust Requirements for the Commonwealth of Massachusetts

Page 5

Note: The following requirements reference various Massachusetts and national codes not contained in this document.

H. Requirements for the Commonwealth of Massachusetts

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, in- cluding but not limited to decks and porches, the following requirements shall be satisfied:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addi- tion, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detec- tor with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fu- eled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that dur- ing said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accor- dance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

Signage

A metal or plastic identification plate shall be permanent- ly mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fu- eled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS

VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- STRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizon- tally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

The equipment listed in Chapter 10 entitled “Equip- ment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

Product Approved side wall horizontally vented gas fu- eled equipment installed in a room or structure sep- arate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

Detailed instructions for the installation of the venting system design or the venting system components; and

A complete parts list for the venting system design or venting system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not pro- vide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer:

The referenced “special venting system” instructions shall be included with the appliance or equipment in- stallation instructions; and

The “special venting systems” shall be Product Ap- proved by the Board, and the instructions for that sys- tem shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Ap- proved side wall horizontally vented gas fueled equip- ment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

See Gas Connection section for additional Common- wealth of Massachusetts requirements.

Heat & Glo • Cyclone-Cust2061-900 Rev. L • 10/08

5

Image 5
Contents Hot glass will cause burns Model Cyclone-CustWhat to do if you smell gas Homeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Design and Installation ConsiderationsInspect Appliance and Components Tools and Supplies NeededModel Framing and ClearancesSelecting Appliance Location Clearances to Combustibles Inches Constructing the Appliance ChaseClearances 34-3/8 Mantel Projections41-3/8 +0 to -1/2See .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination One Elbow Vent DiagramsTwo Elbows VT Min HT MaxTop Vent Horizontal Termination Three Elbows Flue Restrictor Top Vent Vertical Termination No ElbowTop Vent Vertical Termination Three Elbows Pipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationVertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Securing and Leveling the Appliance Appliance PreparationAssembly of Vent Sections Installing Vent PipeDVP Series Venting Only Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical Sections Heat Shield Requirements for Horizontal Termination Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Roof Pitch Min. Ft Installing Roof Flashing and Vertical Ter- mination Cap18 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas InformationGas Pressures Gas ConnectionHigh Altitude Installations Electrical Information Recommendation for WireOptional Accessories Requirements Connecting to the ApplianceHot Surface Ignition Wiring Facing Material FinishingClean the Appliance Appliance SetupAccessories Glass Assembly InstallationBefore Lighting Appliance Operating InstructionsFinal inspection by Turn off all electric power to the applianceLighting Appliance HSI Ignition After Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Maintaining and Servicing Appliance Fan Motor ServiceHeat & Glo Cyclone-Cust 2061-900 Rev. L 10/08 Inspect Maintenance Tasks Maintenance TasksLocation Inches Millimeter Appliance Dimension DiagramReference Materials DVP vent components Vent Components DiagramsDVP vent components DVP-HSM-B At Depot Service PartsStocked Valve Assembly CONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

Cyclone-Cust specifications

Hearth and Home Technologies has made significant strides in the realm of home heating with its innovative Cyclone-Cust fireplace technology. Designed for modern living spaces, the Cyclone-Cust combines efficiency, aesthetics, and advanced features, making it a popular choice among homeowners seeking both style and functionality.

One of the standout features of the Cyclone-Cust is its unique combustion system. This fireplace employs a patented cyclone burn technology that ensures a more complete and efficient burn of wood or gas fuels. As a result, it produces less smoke and harmful emissions, making it an environmentally friendly option. The advanced combustion technology also contributes to increased heat output, allowing users to enjoy a warm and cozy environment without the need for excessive fuel consumption.

The Cyclone-Cust is engineered with user convenience in mind. Its intuitive control panel allows homeowners to regulate heat output and flame intensity effortlessly. The fireplace can be operated remotely, providing a modern touch that enhances user convenience. Additionally, the unit is equipped with smart technology that can integrate seamlessly with home automation systems. This feature allows users to monitor and control their fireplace from their smartphone or tablet, adding an extra layer of convenience.

Aesthetically, the Cyclone-Cust does not disappoint. It is available in various designs and finishes, allowing homeowners to select an option that complements their interior decor. The striking flame pattern creates a captivating visual experience, serving as a focal point in any living space. Whether you prefer a traditional look or a contemporary style, the Cyclone-Cust can be customized to suit your taste.

Safety is another key characteristic of Hearth and Home Technologies’ Cyclone-Cust fireplaces. The unit is designed with multiple safety features, including glass doors to prevent the accidental escape of sparks and embers. The built-in air wash system helps keep the glass clean, ensuring an unobstructed view of the flames while enhancing safety for families with children or pets.

In summary, the Hearth and Home Technologies Cyclone-Cust fireplace merges efficiency, convenience, safety, and aesthetic appeal into a single unit. Its advanced combustion technology, user-friendly controls, and customizable designs make it a standout option for those looking to enhance their home heating experience. With the Cyclone-Cust, homeowners can enjoy a sophisticated source of warmth that aligns with modern lifestyle demands and environmental considerations.