Hearth and Home Technologies 844-4120, 839-1340, 839-1320 Gas Connection, Check for GAS Leaks

Page 26

C. Gas Connection

NOTE: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI Z223.1. Instal- lation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.)

NOTE: A listed (and Commonwealth of Massachusetts approved) 1/2 inch (13mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 inch (13mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

WARNING

Gas Leak Risk.

Support control when attaching pipe to prevent bending gas line.

NOTE: The gap between the supply piping and gas access hole may be plugged with non-combustible insulation to prevent cold air infiltration.

Leak test all gas line joints and the gas control valve prior to and after starting the fireplace.

Before making the gas connection, ensure that the appliance you are installing is designed for the type of gas being supplied. This information can be found on the Ratings Label under the appliance. If the appliance has been converted to propane (LP), the valve cover should have a label stating that the unit has been converted to propane.

Connect the gas line at the 3/8 in. (9.5mm) pipe connector on the valve at the back of appliance. We recommend connecting the appliance with an approved flex gas line. If flex gas lines are not approved in your area, you must connect a hard pipe to the gas hookup.

You must supply a manual shut-off valve in a visible location within 3 feet (914mm) of the appliance.

WARNING

Fire or Explosion Hazard

Gas build-up during line purge may ignite.

Purge should be performed by qualified technician.

Ensure adequate ventilation.

• Ensure there are no ignition sources such as sparks or open flame.

A small amount of air will be in the gas supply lines. When first lighting appliance it will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally.

Air only needs to be purged again if gas valve has been turned to the OFF position.

WARNING

CHECK FOR GAS LEAKS

Explosion Risk

Fire Risk

Asphyxiation Risk

Check all fittings and connections.

Do not use open flame.

After the gas line installation is complete, all connections must be tightened and checked for leaks with a commercially-available, non-corrosive leak check solution. Be sure to rinse off all leak check solution following testing.

Fittings and connections may have loosened during shipping and handling.

WARNING

Fire hazard.

Do NOT change the valve settings.

This valve has been preset at the factory.

Changing valve settings may result in fire hazard or bodily injury.

Omni-Test Laboratories listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and 0 to 4500 feet in Canada.

When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities.

Page 26

Quadra-Fire · Topaz · 7009-113G

September 1, 2008

Image 26
Contents What to do if you smell gas Do not Discard this ManualDo Discardnot Hot glass will cause burnsWelcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Getting Started Design & Installation ConsiderationsTools will apply to every installation Inspect Appliance & ComponentsSelecting Appliance Location Clearances4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Use of Elbows Vent InformationVenting Components Measuring StandardsFrom Appliance to How to Use the Vent Graph Venting GuidelinesVertical Distance ElbowHorizontal Termination Type a Up & Out Installations for Top Vent ConfigurationsType B Rear Installations for Use with Rear Vent Kit StepTop Vent 203mm Step Vertical TerminationDirect Vent Pipe Ceiling Joists Framing 2 in mm Long Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type a Up & Out Installations for Top Vent Configurations Existing Masonry ChimneyCut and bend flashing as needed to fit Sealant adhesive Retro Connector Converting to LP Gas Gas InformationFuel Conversions Valve Regulator Replacement Pull off pilot hood and set it asideGas Pressures PressureGas Connection Check for GAS LeaksStanding Pilot Ignition System Wiring Recommendation for WireConnecting to the Appliance Wire Size Max. LengthON/OFF Top to Rear Vent Conversion Appliance SetupRemove Shipping Materials Accessories Leg Leveling SystemFor Both Quartet and Solitaire Fronts Front Installation Fronts shipped attached to faceBrick Installation Positioning the Logs Qty DescriptionLocater Pins Mineral WoolGlass Door Assembly Replacement Blower InstallationWhite For TOP or Rear Vent Installations Damper AdjustmentShutter Adjustment Make adjustmentControls Operating InstructionsBefore Lighting Appliance For Your Safety Read Before Lighting Lighting ApplianceAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsSeptember 1 Quadra-Fire · Topaz · 7009-113G Vent Components DiagramMm inner pipe 6-5/8 in mm outer pipe Vent Components List HHT SL-PTermination Caps & Kits Topaz Item # DescriptionService Parts List cont’d RV-TPZ-CCR BRICK-TOPAZ Cast Parts Individual PiecesAccessories Service and Maintenance Log Date of Service Performed By Description of ServiceWarranty Policy Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityHearth & Home Technologies Limited Warranty Cont’d Dealer Telephone TopazContact Information

TOPAZ-D-CWL, 844-4120, TOPAZ-D-CSB, 839-1320, 839-1290 specifications

Hearth and Home Technologies, a leader in the hearth industry, offers a diverse range of products characterized by exceptional design, advanced technologies, and unparalleled functionality. Among their popular models are the 839-1340, 839-1290, 839-1320, TOPAZ-D-CSB, and 844-4120, each designed to meet different aesthetic and functional requirements.

The 839-1340 model stands out with its innovative fire viewing area and modern clean lines. It features a powerful heat output, ensuring efficient warmth for larger spaces. Equipped with advanced combustion technology, this model minimizes emissions while maximizing efficiency. The adjustable flame settings allow users to customize the ambiance of their living space, creating just the right atmosphere.

Moving on to the 839-1290, this model offers a sleek and minimalist design, making it suitable for various interior styles. Its compact size does not compromise on performance; it generates ample heat while maintaining an eco-friendly footprint. Featuring a unique air wash system, the 839-1290 keeps the glass clear, ensuring a beautiful view of the flames at all times.

The 839-1320 is another exceptional offering from Hearth and Home Technologies. This unit incorporates a modern aesthetic with its bold fireplace design, ideal for contemporary homes. It is designed for ease of installation and maintenance, making it a favorite among homeowners and installers alike. The combustion system in this unit is optimized for efficiency, which leads to lower fuel consumption and reduced utility costs.

The TOPAZ-D-CSB is recognized for its versatility, integrating seamlessly into various settings. This model is distinguished by its dual-fuel capability, allowing for either wood or gas as fuel sources. With its elaborate design and customizable options, users can truly personalize their experience. The TOPAZ-D-CSB also features cutting-edge safety controls and intelligent temperature management systems to provide peace of mind.

Lastly, the 844-4120 showcases Hearth and Home Technologies’ commitment to innovation. This model features state-of-the-art electronics for easy control of functions, making user interaction intuitive. It also benefits from a highly efficient heat exchanger, allowing for warmth distribution throughout the room. The stylish design combined with robust performance makes the 844-4120 a top choice for discerning homeowners.

In summary, Hearth and Home Technologies provides a remarkable selection of fireplace products that blend contemporary design with advanced functionality. Each model offers unique features and technologies, ensuring homeowners can find the ideal solution for their heating and aesthetic needs.