Hearth and Home Technologies 839-1320, 839-1340, 844-4120 Selecting Appliance Location, Clearances

Page 7

3

Appliance Location and Clearances

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

WARNING

 

· Illustrations reflect typical installations and are FOR

 

 

 

 

 

Fire Risk

DESIGN PURPOSES ONLY.

 

· Illustrations/diagrams are not drawn to scale.

 

Provide adequate clearance:

 

Around air openings

 

· Actual installation may vary due to individual design

 

To combustibles

preference.

 

For service access

Locate appliance away from traffic areas.

A. Selecting Appliance Location

When selecting a location for your appliance it is important to consider the required clearances to walls (see Figure 3.1).

B. Clearances

WARNING

Fire Risk.

Locate and install appliance to all clearance specifications in manual.

 

F

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

C

 

 

 

 

 

G

 

 

 

 

 

 

 

B

 

 

 

 

 

 

A

A

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

A

A

 

 

 

 

C

 

 

 

 

 

Model

 

A

B

C

D

E

F

G

 

 

Topaz

Inches

6-1/2

6

1

54

36

40

23

 

 

 

Millimeters

165

152

25

1372

914

1016

584

 

Figure 3.1

 

 

 

 

 

 

 

 

 

 

It is permissible to place the appliance on carpet.

CAUTION

Some carpet materials may be sensitive to radiant heat from the appliance causing discoloration or odor.

NOTE: Flooring beneath appliance may reach 90 degrees plus room ambient temperature. Check with flooring manufacturer for maximum temperature allowed on flooring surfaces.

WARNING

Fire Risk.

Odor Risk.

Tipping Risk

Install appliance on a stable, level platform/ floor strong enough to support appliance without tipping.

USE wood flooring, ceramic tile, brick hearth or high pressure laminate flooring applied directly over the sub-flooring material.

September 1, 2008

Quadra-Fire · Topaz · 7009-113G

Page 7

Image 7
Contents Hot glass will cause burns Do not Discard this ManualDo Discardnot What to do if you smell gasWelcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals BELOW. Keep Clear of ALL Obstructions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Inspect Appliance & Components Design & Installation ConsiderationsTools will apply to every installation Getting StartedClearances Selecting Appliance LocationVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsElbow How to Use the Vent Graph Venting GuidelinesVertical Distance From Appliance toStep Type a Up & Out Installations for Top Vent ConfigurationsType B Rear Installations for Use with Rear Vent Kit Horizontal TerminationTop Vent 203mm Direct Vent Pipe Vertical TerminationStep Ceiling Joists Framing 2 in mm Long Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Type a Up & Out Installations for Top Vent ConfigurationsCut and bend flashing as needed to fit Sealant adhesive Retro Connector Fuel Conversions Gas InformationConverting to LP Gas Pull off pilot hood and set it aside Valve Regulator ReplacementPressure Gas PressuresCheck for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringON/OFF Remove Shipping Materials Appliance SetupTop to Rear Vent Conversion Leg Leveling System AccessoriesBrick Installation Front Installation Fronts shipped attached to faceFor Both Quartet and Solitaire Fronts Qty Description Positioning the LogsMineral Wool Locater PinsBlower Installation Glass Door Assembly ReplacementWhite Make adjustment Damper AdjustmentShutter Adjustment For TOP or Rear Vent InstallationsBefore Lighting Appliance Operating InstructionsControls Lighting Appliance For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramMm inner pipe 6-5/8 in mm outer pipe Vent Components DiagramSeptember 1 Quadra-Fire · Topaz · 7009-113G HHT SL-P Vent Components ListTermination Caps & Kits Item # Description TopazService Parts List cont’d RV-TPZ-CCR Cast Parts Individual Pieces BRICK-TOPAZAccessories Date of Service Performed By Description of Service Service and Maintenance LogCONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Contact Information TopazDealer Telephone

TOPAZ-D-CWL, 844-4120, TOPAZ-D-CSB, 839-1320, 839-1290 specifications

Hearth and Home Technologies, a leader in the hearth industry, offers a diverse range of products characterized by exceptional design, advanced technologies, and unparalleled functionality. Among their popular models are the 839-1340, 839-1290, 839-1320, TOPAZ-D-CSB, and 844-4120, each designed to meet different aesthetic and functional requirements.

The 839-1340 model stands out with its innovative fire viewing area and modern clean lines. It features a powerful heat output, ensuring efficient warmth for larger spaces. Equipped with advanced combustion technology, this model minimizes emissions while maximizing efficiency. The adjustable flame settings allow users to customize the ambiance of their living space, creating just the right atmosphere.

Moving on to the 839-1290, this model offers a sleek and minimalist design, making it suitable for various interior styles. Its compact size does not compromise on performance; it generates ample heat while maintaining an eco-friendly footprint. Featuring a unique air wash system, the 839-1290 keeps the glass clear, ensuring a beautiful view of the flames at all times.

The 839-1320 is another exceptional offering from Hearth and Home Technologies. This unit incorporates a modern aesthetic with its bold fireplace design, ideal for contemporary homes. It is designed for ease of installation and maintenance, making it a favorite among homeowners and installers alike. The combustion system in this unit is optimized for efficiency, which leads to lower fuel consumption and reduced utility costs.

The TOPAZ-D-CSB is recognized for its versatility, integrating seamlessly into various settings. This model is distinguished by its dual-fuel capability, allowing for either wood or gas as fuel sources. With its elaborate design and customizable options, users can truly personalize their experience. The TOPAZ-D-CSB also features cutting-edge safety controls and intelligent temperature management systems to provide peace of mind.

Lastly, the 844-4120 showcases Hearth and Home Technologies’ commitment to innovation. This model features state-of-the-art electronics for easy control of functions, making user interaction intuitive. It also benefits from a highly efficient heat exchanger, allowing for warmth distribution throughout the room. The stylish design combined with robust performance makes the 844-4120 a top choice for discerning homeowners.

In summary, Hearth and Home Technologies provides a remarkable selection of fireplace products that blend contemporary design with advanced functionality. Each model offers unique features and technologies, ensuring homeowners can find the ideal solution for their heating and aesthetic needs.