Hearth and Home Technologies 839-1290, 839-1340 Electrical Information, Recommendation for Wire

Page 27

7Electrical Information

A. Recommendation for Wire

See B5 below for recommended maximum lead length (two wire) when using wall thermostat/switch.

NOTE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA

C221.1.

B. Connecting to the Appliance

WARNING

Wire 110v to electrical junction box.

Do NOT wire 110v to the valve.

Do NOT wire 110V to wall switch.

Incorrect wiring will damage millivolt systems.

1.This appliance may be used with a wall switch, wall mounted thermostat and / or a remote control.

2.If using thermostat, use one compatible with a millivolt gas valve system.

3.Follow parameters for locating thermostat (see individ- ual thermostat instructions) to ensure proper operation of appliance.

4.Use low resistance thermostat wire for wiring from igni- tion system to the wall switch and thermostat.

5.Use the following chart for wire sizing.

Wire Size

Max. Length

16 gauge

65 feet

18 gauge

40 feet

20 gauge

25 feet

22 gauge

18 feet

8.Ensure the thermostat is mounted level for accurate readings.

9.The thermostat should be mounted on an inside wall and not in direct line with the appliance convection air.

10.If the thermostat is located too close to the appliance, you may need to set the temperature setting slightly higher to maintain the desired temperature in your home.

Do not connect this appliance to a thermostat serving any other appliance.

Bedroom installation in Canada requires this appliance to be connected to a thermostat.

WARNING

Shock hazard.

This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle. Do not cut or remove the grounding prong from this plug.

C.Standing Pilot Ignition System Wiring

This appliance DOES NOT require 110 VAC supply for operation. A wiring diagram is shown in Figure 7.1 on the next page.

This appliance is equipped with a millivolt control valve.

6.Keep wire lengths as short as possible by removing any excess wire length.

7.Low voltage and 110 VAC voltage cannot be shared within the same wall box.

September 1, 2008

Quadra-Fire · Topaz · 7009-113G

Page 27

Image 27
Contents Hot glass will cause burns Do not Discard this ManualDo Discardnot What to do if you smell gasWelcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Inspect Appliance & Components Design & Installation ConsiderationsTools will apply to every installation Getting StartedClearances Selecting Appliance LocationVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsElbow How to Use the Vent Graph Venting GuidelinesVertical Distance From Appliance toStep Type a Up & Out Installations for Top Vent ConfigurationsType B Rear Installations for Use with Rear Vent Kit Horizontal TerminationTop Vent 203mm Vertical Termination Direct Vent PipeStep Ceiling Joists Framing 2 in mm Long Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Type a Up & Out Installations for Top Vent ConfigurationsCut and bend flashing as needed to fit Sealant adhesive Retro Connector Gas Information Fuel ConversionsConverting to LP Gas Pull off pilot hood and set it aside Valve Regulator ReplacementPressure Gas PressuresCheck for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringON/OFF Appliance Setup Remove Shipping MaterialsTop to Rear Vent Conversion Leg Leveling System AccessoriesFront Installation Fronts shipped attached to face Brick InstallationFor Both Quartet and Solitaire Fronts Qty Description Positioning the LogsMineral Wool Locater PinsBlower Installation Glass Door Assembly ReplacementWhite Make adjustment Damper AdjustmentShutter Adjustment For TOP or Rear Vent InstallationsOperating Instructions Before Lighting ApplianceControls Lighting Appliance For Your Safety Read Before LightingFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramVent Components Diagram Mm inner pipe 6-5/8 in mm outer pipeSeptember 1 Quadra-Fire · Topaz · 7009-113G HHT SL-P Vent Components ListTermination Caps & Kits Item # Description TopazService Parts List cont’d RV-TPZ-CCR Cast Parts Individual Pieces BRICK-TOPAZAccessories Date of Service Performed By Description of Service Service and Maintenance LogCONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Topaz Contact InformationDealer Telephone

TOPAZ-D-CWL, 844-4120, TOPAZ-D-CSB, 839-1320, 839-1290 specifications

Hearth and Home Technologies, a leader in the hearth industry, offers a diverse range of products characterized by exceptional design, advanced technologies, and unparalleled functionality. Among their popular models are the 839-1340, 839-1290, 839-1320, TOPAZ-D-CSB, and 844-4120, each designed to meet different aesthetic and functional requirements.

The 839-1340 model stands out with its innovative fire viewing area and modern clean lines. It features a powerful heat output, ensuring efficient warmth for larger spaces. Equipped with advanced combustion technology, this model minimizes emissions while maximizing efficiency. The adjustable flame settings allow users to customize the ambiance of their living space, creating just the right atmosphere.

Moving on to the 839-1290, this model offers a sleek and minimalist design, making it suitable for various interior styles. Its compact size does not compromise on performance; it generates ample heat while maintaining an eco-friendly footprint. Featuring a unique air wash system, the 839-1290 keeps the glass clear, ensuring a beautiful view of the flames at all times.

The 839-1320 is another exceptional offering from Hearth and Home Technologies. This unit incorporates a modern aesthetic with its bold fireplace design, ideal for contemporary homes. It is designed for ease of installation and maintenance, making it a favorite among homeowners and installers alike. The combustion system in this unit is optimized for efficiency, which leads to lower fuel consumption and reduced utility costs.

The TOPAZ-D-CSB is recognized for its versatility, integrating seamlessly into various settings. This model is distinguished by its dual-fuel capability, allowing for either wood or gas as fuel sources. With its elaborate design and customizable options, users can truly personalize their experience. The TOPAZ-D-CSB also features cutting-edge safety controls and intelligent temperature management systems to provide peace of mind.

Lastly, the 844-4120 showcases Hearth and Home Technologies’ commitment to innovation. This model features state-of-the-art electronics for easy control of functions, making user interaction intuitive. It also benefits from a highly efficient heat exchanger, allowing for warmth distribution throughout the room. The stylish design combined with robust performance makes the 844-4120 a top choice for discerning homeowners.

In summary, Hearth and Home Technologies provides a remarkable selection of fireplace products that blend contemporary design with advanced functionality. Each model offers unique features and technologies, ensuring homeowners can find the ideal solution for their heating and aesthetic needs.