D. After Appliance is Lit

Initial Break-in Procedure

When you light your appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours to fully drive off any odor from paint and lubricants used in the manufacturing process. Condensation on the glass is normal.

NOTE: The appliance should be run three to four hours on the initial start-up. Turn it off and let it cool completely. Remove and clean the glass. Replace the glass and run the appliance for an additional 12 hours. This will help to cure the products used in the paint and logs.

During this break-in period it is recommended that some windows in the house be opened for air circulation. This will help avoid setting off smoke detectors, and help eliminate any odors associated with the appliance’s initial burning.

WARNING

Fire Risk.

High Temperatures.

Keep combustible household items away from appliance. Do NOT obstruct combustion and ventilation air.

Do NOT place combustible items on top of or in front of appliance.

Keep furniture, draperies away from appliance.

CAUTION

Prevent accidental appliance operation when not attended.

Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time.

Property damage possible from elevated temperatures.

CAUTION

Smoke and odors released during initial operation.

Open windows for air circulation.

Leave room during initial operation.

Smoke may set off smoke detectors.

Smoke and odors may be irritating to sensitive individuals.

WARNING

Fire Hazard.

Keep combustible materials, gasoline and other flammable vapors and liquids clear of appliance.

Do NOT store flammable materials in the appliance’s vicinity.

Do NOT use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids in this appliance.

Combustible materials may ignite.

E. Frequently Asked Questions

ISSUE

SOLUTIONS

Condensation on the glass

This is a result of gas combustion and temperature variations. As the appliance warms,

 

this condensation will disappear.

Blue flames

This is a result of normal operation and the flames will begin to yellow as the appliance

 

is allowed to burn for 20 to 40 minutes.

Odor from appliance

When first operated, this appliance may release an odor for the first several hours.

 

This is caused by the curing of the paint and the burning off of any oils remaining from

 

manufacturing. If appliance has not been used for some time, dust can build up and

 

cause an odor.

Film on the glass

This is a normal result of the curing process of the paint and logs. Glass should be

 

cleaned within 3 to 4 hours of initial burning to remove deposits left by oils from the

 

manufacturing process. A non-abrasive cleaner such as gas appliance cleaner may be

 

necessary. See your dealer.

Metallic noise

Noise is caused by metal expanding and contracting as it heats up and cools down,

 

similar to the sound produced by a furnace or heating duct. This noise does not affect

 

the operation or longevity of the appliance.

September 1, 2008

Quadra-Fire · Topaz · 7009-113G

Page 39

Image 39
Contents Hot glass will cause burns Do not Discard this ManualDo Discardnot What to do if you smell gasWelcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals Requirements for the Commonwealth of Massachusetts BELOW. Keep Clear of ALL ObstructionsManufacturer Requirements Inspect Appliance & Components Design & Installation ConsiderationsTools will apply to every installation Getting StartedClearances Selecting Appliance LocationVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsElbow How to Use the Vent Graph Venting GuidelinesVertical Distance From Appliance toStep Type a Up & Out Installations for Top Vent ConfigurationsType B Rear Installations for Use with Rear Vent Kit Horizontal TerminationTop Vent 203mm Vertical Termination Direct Vent PipeStep Ceiling Joists Framing 2 in mm Long Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Existing Masonry Chimney Type a Up & Out Installations for Top Vent ConfigurationsCut and bend flashing as needed to fit Sealant adhesive Retro Connector Gas Information Fuel ConversionsConverting to LP Gas Pull off pilot hood and set it aside Valve Regulator ReplacementPressure Gas PressuresCheck for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringON/OFF Appliance Setup Remove Shipping MaterialsTop to Rear Vent Conversion Leg Leveling System AccessoriesFront Installation Fronts shipped attached to face Brick InstallationFor Both Quartet and Solitaire Fronts Qty Description Positioning the LogsMineral Wool Locater PinsBlower Installation Glass Door Assembly ReplacementWhite Make adjustment Damper AdjustmentShutter Adjustment For TOP or Rear Vent InstallationsOperating Instructions Before Lighting ApplianceControls Lighting Appliance For Your Safety Read Before LightingFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramVent Components Diagram Mm inner pipe 6-5/8 in mm outer pipeSeptember 1 Quadra-Fire · Topaz · 7009-113G HHT SL-P Vent Components ListTermination Caps & Kits Item # Description TopazService Parts List cont’d RV-TPZ-CCR Cast Parts Individual Pieces BRICK-TOPAZAccessories Date of Service Performed By Description of Service Service and Maintenance LogCONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Topaz Contact InformationDealer Telephone

TOPAZ-D-CWL, 844-4120, TOPAZ-D-CSB, 839-1320, 839-1290 specifications

Hearth and Home Technologies, a leader in the hearth industry, offers a diverse range of products characterized by exceptional design, advanced technologies, and unparalleled functionality. Among their popular models are the 839-1340, 839-1290, 839-1320, TOPAZ-D-CSB, and 844-4120, each designed to meet different aesthetic and functional requirements.

The 839-1340 model stands out with its innovative fire viewing area and modern clean lines. It features a powerful heat output, ensuring efficient warmth for larger spaces. Equipped with advanced combustion technology, this model minimizes emissions while maximizing efficiency. The adjustable flame settings allow users to customize the ambiance of their living space, creating just the right atmosphere.

Moving on to the 839-1290, this model offers a sleek and minimalist design, making it suitable for various interior styles. Its compact size does not compromise on performance; it generates ample heat while maintaining an eco-friendly footprint. Featuring a unique air wash system, the 839-1290 keeps the glass clear, ensuring a beautiful view of the flames at all times.

The 839-1320 is another exceptional offering from Hearth and Home Technologies. This unit incorporates a modern aesthetic with its bold fireplace design, ideal for contemporary homes. It is designed for ease of installation and maintenance, making it a favorite among homeowners and installers alike. The combustion system in this unit is optimized for efficiency, which leads to lower fuel consumption and reduced utility costs.

The TOPAZ-D-CSB is recognized for its versatility, integrating seamlessly into various settings. This model is distinguished by its dual-fuel capability, allowing for either wood or gas as fuel sources. With its elaborate design and customizable options, users can truly personalize their experience. The TOPAZ-D-CSB also features cutting-edge safety controls and intelligent temperature management systems to provide peace of mind.

Lastly, the 844-4120 showcases Hearth and Home Technologies’ commitment to innovation. This model features state-of-the-art electronics for easy control of functions, making user interaction intuitive. It also benefits from a highly efficient heat exchanger, allowing for warmth distribution throughout the room. The stylish design combined with robust performance makes the 844-4120 a top choice for discerning homeowners.

In summary, Hearth and Home Technologies provides a remarkable selection of fireplace products that blend contemporary design with advanced functionality. Each model offers unique features and technologies, ensuring homeowners can find the ideal solution for their heating and aesthetic needs.