C. Assemble Chimney Sections

WARNING! Risk of Fire! DO NOT install substitute or damaged chimney components.

Use only those components described in this manual.

Substitute or damaged chimney components could impair safe operation and cause overheating and fire.

Support the pipe during construction and check to be sure inadvertent loading has not dislodged the chimney section from the fireplace or at any chimney joint.

Attach a straight chimney section or an offset to the top of the fireplace.

Place inner flue to the inside of the chimney section below it. Place the outer casing outside the outer casing of the chimney section below it. Refer to Figure 8.4.

NOTICE: Chimney sections cannot be disassembled once locked together. Plan ahead!

Lock chimney sections and/or offsets/returns together by pushing downward until the top section meets the stop bead on the lower section.

Pull on the top section to make sure it is fully engaged and will not separate.

You may use #6 or #8 sheet metal screws no longer than 1/2 in. (13 mm) to fasten chimney sections together. Do NOT penetrate inner flue.

WARNING! Risk of Fire! You MUST use screws (pro- vided) to fasten offset/returns to chimney sections to keep the chimney parts from twisting. Failure to do so could cause fire.

Fasten offset/returns to chimney sections. Insert the screws (provided) through the predrilled holes. Do NOT penetrate inner flue.

Secure chimney returns with hanger straps provided; fasten to studs or joists.

Vertical straight runs of chimney must be supported every 35 ft (10.7 m).

D. Install Chimney Air Kit

Required in Canada.

Follow instructions provided with this accessory.

Figure 8.4 Assembling Chimney Sections

Heatilator • I60, I80 • 4013-250 • Rev C • 11/08

29

Image 29
Contents Fire Risk Wood Burning FireplaceHot screen/mesh and glass doors will cause burns Number Listing Label Information/LocationGrate User Guide Table of ContentsInstaller Guide CONDITIONS, Exclusions & Limitation of Liability Warranty Hearth & Home Technologies Limited WarrantyHeatilator I60, I80 4013-250 Rev C 11/08 Appliance Certification Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Starting a Fire Seasoned WoodGrate FirescreenVented Gas Log Sets & Gas Log Lighters Glass DoorsOptional Components Clear SpaceWood Fuel Chimney Inspection/Cleaning Maintainance and ServiceDisposal of Ashes Creosote Formation and Need for RemovalCheck Firebox Refractory Glass CleaningInspect Grate Frequency As desiredStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedNegative Pressure Design and Installation ConsiderationsDraft Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Select Fireplace Location Framing & ClearancesClearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsUnpack the Fireplace I80 only Installation of FireplaceThings to Consider Unpack the Fireplace I60 onlyRemoving Smoke Shield Position the Fireplace I80 onlyGAS Knockout Install the Refractory I80 onlyLevel Fireplace Place Protective Metal Hearth StripsYES Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssemble Chimney Sections Install Chimney Air KitInstalling the Ceiling Firestop Install Ceiling Firestops330 mm Install Attic Insulation ShieldInstall Flashing Complete InstallationFollowing steps should be skipped if using a chase Cut out Hole in RoofFlat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyST1175/ST475 Square Termination Cap Install Termination CapTCT1175 Terra Cotta Cap Radiation Shield ShroudsField Constructed Shrouds Open Top Shroud TR11/TR11T caps require radiation shieldRoofed Style Shroud radiation shield required Mailbox Style Shroud radiation shield required= 1/k x inches of thickness FinishingHearth Extension Hearth Extension Construction Raised Hearth Extension FramingFlush Hearth Extension Framing Non-combustible SealantNoncombustible Facing Finishing MaterialCombustible Mantel 19 3/4 502 mm Gas Log/Lighter Provision AccessoriesWood Burning Inserts Gas Code, Ansi Z223.1Reference Materials Fireplace Dimensions13 mm Catalog # Chimney Components15-1/4 387 mm 15-3/4 400 mm CT56 Chase Top LDS33/LDS46 Decorative Shroud This page intentionally left blank Icon I60CT, I60H PartsParts Contact Information

I80, I60 specifications

Hearth and Home Technologies’ I60 and I80 are highly regarded as premier options in the realm of direct vent gas fireplaces. Both models are designed to provide elegant aesthetics and outstanding performance, making them ideal for any living space. The I60 features a 60,000 BTU input, while the I80 boasts a higher input of 80,000 BTUs, ensuring ample warmth and comfort. These fireplaces are well-suited for large rooms and homes with open floor plans, delivering significant efficiency alongside superior design.

One of the standout features of both the I60 and I80 models is their contemporary style. The large glass viewing area creates a stunning visual impact, allowing the flames to be the focal point of the room. The clean, linear design can be customized to fit various décor styles, making it versatile for homeowners. Additionally, the fireplaces can come with optional decorative media such as ceramic logs, stones, or glass, allowing for further personalization.

Both fireplaces incorporate advanced technologies to enhance performance and efficiency. The inclusion of the IntelliFire® ignition system offers a reliable and convenient way to start the fireplace, eliminating the need for messy matches or lighters. The remote control functionality adds convenience, allowing users to adjust flame height and heat output from anywhere in the room.

Efficiency is another key characteristic of the I60 and I80. They boast high-efficiency ratings, contributing to lower energy bills while providing superior warmth. The direct vent technology ensures that combustion gases are expelled outside, preventing indoor air pollution and allowing for excellent airflow.

Installation is also simplified with these models due to their flexible venting options. They can accommodate various venting configurations, including horizontal and vertical installations, which is particularly beneficial in both new construction and retrofit applications. The fireplaces come equipped with safety features such as a standard safety screen and optional glass doors, ensuring peace of mind for users.

In summary, Hearth and Home Technologies’ I60 and I80 gas fireplaces offer an exceptional combination of style, efficiency, and advanced features. With their contemporary design, customizable media options, reliable ignition system, and high efficiency, they stand out as reliable heating solutions for modern homes. Whether for comfortable warmth or creating an inviting ambience, these models are sure to enhance any living space.