B. Seasoned Wood

Properly seasoned wood is important for successful operation of your fireplace. Most woodburning fireplace problems are caused by burning wet, unseasoned wood.

Seasoned firewood is wood that is cut to size, split and air dried to a moisture content of around 20%.

Imagine a wooden bucket that weighs about eight pounds. Fill it with a gallon of water, put it in the fireplace and try to burn it. This sounds ridiculous but that is exactly what you are doing if you burn unseasoned wood.

A tree cut down a year ago and not split is likely to have almost as high a moisture content now as it did when it was cut.

Please refer to Section 2.M. for more detail.

C. Starting a Fire

NOTICE: You must establish a good draft to prevent smoke spillage into the room.

WARNING! Risk of Fire! Keep combustible materials, gasoline and other flammable vapors and liquids clear of the fireplace.

DO NOT:

store flammable materials close to the fireplace

use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or “freshen up” a fire in this fireplace.

Keep all flammable liquids well away from the fireplace while it is in use. Combustible materials may ignite.

The first three or four fires should be of moderate size to allow the oils and binders to be burned from the fireplace and the refractory and paint to cure. You may notice an industrial odor the first few fires. This is considered normal.

Use well-seasoned wood.

Open the flue damper to a fully open position.

Place crumpled or twisted paper under the fireplace grate.

Loosely arrange kindling or small pieces of wood to form a ‘tent’ on the fireplace grate.

Pre-warm the flue to establish a draft to help reduce smoke spillage during start-up. Hold a rolled up piece of burning newspaper under the flue damper for a few moments.

Light the crumpled paper to ignite the kindling.

Add small pieces of wood until a hot bed of embers has been established.

Add a minimum of three average size pieces of split firewood, placed to allow combustion air and flames between them.

CAUTION! Odors and vapors released during initial operation may be irritating to sensitive individuals.

Open windows for air circulation.

D. Grate

This fireplace is designed to be used with the grate sup- plied with this unit or one approved by HHT. The grate will break down over time and will need occasional replace- ment.

WARNING! Risk of Fire! Use only the factory-supplied integral grate.

Keeps logs in place.

Allows proper air circulation around the fire.

E. Firescreen

The firescreen is provided to control sparks. Keep it closed when the fireplace is in use.

WARNING! Risk of Fire or Burns!

Screen will not prevent burning materials from falling out.

Screen pulls or handles may be hot.

F. Flue Damper

Refer to Figure 2.1 for location of control.

Must be in fully open position (handle up toward the top of the fireplace) during operation of the fireplace.

Before lighting the fireplace, verify fully open position by looking up from the inside of the fireplace.

WARNING! Risk of Fire and Asphyxiation! Open damper prior to operating fireplace. A closed damper overfires the fireplace and spills smoke and flames into the room.

G. Refractory

The refractory is supplied to contain heat and provide an attractive interior.

It will break down over time and will need occasional replacement. Small hairline cracks and discoloration are normal and do not affect its safety.

(See refractory maintenance Section 3.C.)

WARNING! Risk of Fire! DO NOT burn fireplace with- out refractory. Use only refractory supplied by Hearth & Home Technologies, Inc.

8

Heatilator • I60, I80 • 4013-250 • Rev C • 11/08

Image 8
Contents Fire Risk Wood Burning FireplaceHot screen/mesh and glass doors will cause burns Number Listing Label Information/LocationGrate User Guide Table of ContentsInstaller Guide Warranty Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityHeatilator I60, I80 4013-250 Rev C 11/08 Listing and Code Approvals Appliance CertificationNon-Combustible Materials Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Seasoned Wood Starting a FireGrate FirescreenGlass Doors Vented Gas Log Sets & Gas Log LightersOptional Components Clear SpaceWood Fuel Maintainance and Service Chimney Inspection/CleaningDisposal of Ashes Creosote Formation and Need for RemovalGlass Cleaning Check Firebox RefractoryInspect Grate Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemNegative Pressure Design and Installation ConsiderationsDraft Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Framing & Clearances Select Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the FireplaceInstallation of Fireplace Unpack the Fireplace I80 onlyThings to Consider Unpack the Fireplace I60 onlyPosition the Fireplace I80 only Removing Smoke ShieldInstall the Refractory I80 only GAS KnockoutPlace Protective Metal Hearth Strips Level FireplaceInstall Outside Air Kit YESChimney Assembly Chimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleInstall Chimney Air Kit Assemble Chimney SectionsInstall Ceiling Firestops Installing the Ceiling FirestopInstall Attic Insulation Shield 330 mmComplete Installation Install FlashingFollowing steps should be skipped if using a chase Cut out Hole in RoofChimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Fireplace & Chimney Install Chase TopInstall Termination Cap ST1175/ST475 Square Termination CapTCT1175 Terra Cotta Cap Shrouds Radiation ShieldField Constructed Shrouds Open Top Shroud TR11/TR11T caps require radiation shieldMailbox Style Shroud radiation shield required Roofed Style Shroud radiation shield required= 1/k x inches of thickness FinishingHearth Extension Raised Hearth Extension Framing Hearth Extension ConstructionNon-combustible Sealant Flush Hearth Extension FramingFinishing Material Noncombustible FacingCombustible Mantel 19 3/4 502 mm Accessories Gas Log/Lighter ProvisionWood Burning Inserts Gas Code, Ansi Z223.1Fireplace Dimensions Reference Materials13 mm Chimney Components Catalog #15-1/4 387 mm 15-3/4 400 mm CT56 Chase Top LDS33/LDS46 Decorative Shroud This page intentionally left blank Parts Icon I60CT, I60HParts Contact Information

I80, I60 specifications

Hearth and Home Technologies’ I60 and I80 are highly regarded as premier options in the realm of direct vent gas fireplaces. Both models are designed to provide elegant aesthetics and outstanding performance, making them ideal for any living space. The I60 features a 60,000 BTU input, while the I80 boasts a higher input of 80,000 BTUs, ensuring ample warmth and comfort. These fireplaces are well-suited for large rooms and homes with open floor plans, delivering significant efficiency alongside superior design.

One of the standout features of both the I60 and I80 models is their contemporary style. The large glass viewing area creates a stunning visual impact, allowing the flames to be the focal point of the room. The clean, linear design can be customized to fit various décor styles, making it versatile for homeowners. Additionally, the fireplaces can come with optional decorative media such as ceramic logs, stones, or glass, allowing for further personalization.

Both fireplaces incorporate advanced technologies to enhance performance and efficiency. The inclusion of the IntelliFire® ignition system offers a reliable and convenient way to start the fireplace, eliminating the need for messy matches or lighters. The remote control functionality adds convenience, allowing users to adjust flame height and heat output from anywhere in the room.

Efficiency is another key characteristic of the I60 and I80. They boast high-efficiency ratings, contributing to lower energy bills while providing superior warmth. The direct vent technology ensures that combustion gases are expelled outside, preventing indoor air pollution and allowing for excellent airflow.

Installation is also simplified with these models due to their flexible venting options. They can accommodate various venting configurations, including horizontal and vertical installations, which is particularly beneficial in both new construction and retrofit applications. The fireplaces come equipped with safety features such as a standard safety screen and optional glass doors, ensuring peace of mind for users.

In summary, Hearth and Home Technologies’ I60 and I80 gas fireplaces offer an exceptional combination of style, efficiency, and advanced features. With their contemporary design, customizable media options, reliable ignition system, and high efficiency, they stand out as reliable heating solutions for modern homes. Whether for comfortable warmth or creating an inviting ambience, these models are sure to enhance any living space.