Hearth and Home Technologies I80 owner manual Parts, Icon I60CT, I60H

Page 54

54

Service Parts

ICON (I60CT, I60H)

Service Parts Diagram

Beginning Manufacturing Date: Mar 2004

36 in. Woodburning Fireplace

Ending Manufacturing Date: Active

Service Parts

ICON (I60CT, I60H)

Service Parts Diagram

Beginning Manufacturing Date: Mar 2004

36 in. Woodburning Fireplace

Ending Manufacturing Date: Active

D. Service

Heatilator • I60, I80 • 4013

Refractories

TraditionalHerringbone

5

6

8

7

1

2

3

4

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement

 

Stocked

parts for your appliance please provide model number and serial number. All parts listed

 

in this manual may be ordered from an authorized dealer.

 

 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

 

1

Starter Section Assembly

 

22072B

Y

2

Damper Blade Assembly

 

29964

 

3

Damper Control

 

20549

 

 

Damper Weight

 

19785A

 

4

Rear Top Standoff

Qty. 2 req.

19228

 

5

Front Top Standoff

Qty. 2 req.

11864i

 

6

Top Front Face

Overlay Only

31313

 

7

Grate

 

GR30

 

8

Upper Front

 

4013-206

 

9

Smoke Shield

 

32949

Y

10

Firescreen Assembly

 

33699

Y

 

Firescreen Handle

1 ea.

4021-150

 

 

Firescreen Rod

Qty. 2 req.

12052

 

 

Grate Retainer

Qty. 2 req.

34555

 

 

Nailing Flange

Qty. 4 req.

31190

 

 

Outside Air Kit

 

AK22

 

 

Fastener Pack

 

17916B

 

 

Outside Air Shield

 

33271

Y

 

4 in. Outside Air Inlet Ring

 

25692

 

 

Refractory Retainer

Qty. 3 req.

11847

 

 

Screen Cover (top only)

Qty. 2 req.

31319

 

 

Side Trim

Qty. 2 req.

31326

 

Parts

-250 • Rev C • 11/08

9

10

Part number list on following page.

11/08

 

Strip Protector

Qty. 2 req.

18320

 

Powder Coat Touch-Up Paint

 

71479

Herringbone Refractory (I60H)

 

 

 

Brick Refractory - Back

 

33676

 

Brick Refractory - Hearth

 

11847

 

Brick Refractory - Left Side

 

33677

 

Brick Refractory - Right Side

 

33003

Traditional Refractory (I60CT)

 

 

 

Brick Refractory - Hearth

 

11847

 

Brick Refractory - Back- 3 Color- No longer Available

Pre AK994430

4013-193

 

Brick Refractory - Back- 2 Color

Post AK994430

4013-225

 

Brick Refractory - Hearth-3 Color- No longer Available

Pre AK994430

4013-050

 

Brick Refractory - Hearth-2 Color

Post AK994430

4013-223

 

Brick Refractory - Side- 3 Color- No longer Available

Pre AK994430

4013-194

 

Brick Refractory - Side- 2 Color

Post AK994430

4013-224

 

 

 

 

 

Installation Instructions & Owner's Manual

 

4013-250

 

 

 

11/08

Image 54 Contents
Wood Burning Fireplace Hot screen/mesh and glass doors will cause burnsFire Risk Listing Label Information/Location GrateNumber Table of Contents Installer GuideUser Guide Warranty Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityHeatilator I60, I80 4013-250 Rev C 11/08 Non-Combustible Materials Listing and Code ApprovalsAppliance Certification Combustible MaterialsOperating Instructions Your FireplaceHot glass will cause burns Grate Seasoned WoodStarting a Fire FirescreenOptional Components Glass DoorsVented Gas Log Sets & Gas Log Lighters Clear SpaceWood Fuel Disposal of Ashes Maintainance and ServiceChimney Inspection/Cleaning Creosote Formation and Need for RemovalInspect Grate Glass CleaningCheck Firebox Refractory Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemDesign and Installation Considerations DraftNegative Pressure Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsTools and Supplies Needed Fireplace System RequirementsInspect Fireplace and Components Framing & Clearances Select Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the FireplaceThings to Consider Installation of FireplaceUnpack the Fireplace I80 only Unpack the Fireplace I60 onlyPosition the Fireplace I80 only Removing Smoke ShieldInstall the Refractory I80 only GAS KnockoutPlace Protective Metal Hearth Strips Level FireplaceInstall Outside Air Kit YESChimney Assembly Chimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleInstall Chimney Air Kit Assemble Chimney SectionsInstall Ceiling Firestops Installing the Ceiling FirestopInstall Attic Insulation Shield 330 mmFollowing steps should be skipped if using a chase Complete InstallationInstall Flashing Cut out Hole in RoofChimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Fireplace & Chimney Install Chase TopInstall Termination Cap ST1175/ST475 Square Termination CapTCT1175 Terra Cotta Cap Field Constructed Shrouds ShroudsRadiation Shield Open Top Shroud TR11/TR11T caps require radiation shieldMailbox Style Shroud radiation shield required Roofed Style Shroud radiation shield requiredFinishing Hearth Extension= 1/k x inches of thickness Raised Hearth Extension Framing Hearth Extension ConstructionNon-combustible Sealant Flush Hearth Extension FramingFinishing Material Noncombustible FacingCombustible Mantel 19 3/4 502 mm Wood Burning Inserts AccessoriesGas Log/Lighter Provision Gas Code, Ansi Z223.1Fireplace Dimensions Reference Materials13 mm Chimney Components Catalog # 15-1/4 387 mm 15-3/4 400 mm CT56 Chase Top LDS33/LDS46 Decorative Shroud This page intentionally left blank Parts Icon I60CT, I60HParts Contact Information