Hearth and Home Technologies HUDBAY-INS owner manual Gas Connection, Check for GAS Leaks

Page 13

E. Gas Connection

Note: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI

223.1.Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter).

Note: A listed (and Commonwealth of Massachusetts ap- proved) 1/2 inch (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 inch (13 mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

WARNING

Gas Leak Risk

Support control when attaching pipe to prevent bending gas line.

Note: The gap between supply piping and gas access hole may be caulked with high temperature caulk or stuffed with non-combustible, unfaced insulation to prevent cold air infiltration.

Leak test all gas line joints and the gas control valve prior to and after starting the appliance.

Before making the gas connection, ensure that the appliance you are installing is designed for the type of gas being supplied. This information can be found on the ratings label under the appliance. If the appliance has been converted to propane (LP), the valve cover should have a label stating that the appliance has been converted to propane.

Connect the gas line at the 3/8 in. (10 mm) pipe connector on the valve at the back of appliance. We recommend connecting the appliance with an approved flex gas line. If flex gas lines are not approved in your area, you must connect a hard pipe to the gas hookup.

You must supply a manual shut-off valve in a visible location within 3 ft. (914 mm) of the appliance.

Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes.

Incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve.

WARNING

Fire or Explosion Hazard

Gas buildup during line purge may ignite.

Purge should be performed by qualified technician.

Ensure adequate ventilation.

Ensure there are no ignition sources such as sparks or open flames.

A small amount of air will be in the gas supply lines. When first lighting appliance it will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally.

Air only needs to be purged again if gas valve has been turned to the OFF position.

WARNING

CHECK FOR GAS LEAKS

Explosion Risk

Fire Risk

Asphyxiation Risk

Check all fittings and connections.

Do not use open flame.

After the gas line installation is complete, all connections must be tightened and checked for leaks with a commercially-available, non-corrosive leak check solution. Be sure

to rinse off all leak check solution following testing.

Fittings and connections may have loosened during shipping and handling.

WARNING

Fire hazard.

Do NOT change the valve settings.

• This valve has been preset at the factory.

• Changing valve settings may result in fire hazard or bodily injury.

HIGH ALTITUDE INSTALLATIONS

Omni-Test Laboratories, Inc. listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and 0 to 4500 feet in Canada.

When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities.

Quadra-Fire • Hudson Bay Insert • 7008-115 Rev. H • 10/08

13

Image 13
Contents HUDBAY-INS What to do if you smell gasDo Discardnot Welcome to the Quadra-Fire Family Table of Contents Listing and Code Approvals Getting Started Installation to ensure maximum safety and benefitTools and Supplies Needed Read all of the instructions before starting the instaSelecting Appliance Location Framing and ClearancesClearances to Combustibles HearthVent Termination Minimum Clearances Termination LocationsVent Information Venting and InstallationExhaust AIR Vent Pipe Termination CAP Adaptor Fuel Conversions Gas InformationConverting to LP Gas Screws Nuts Holding Burner PANValve Regulator Replacement Gas Pressures Check for GAS Leaks Gas ConnectionConnecting to the Appliance Recommendation for WireStanding Pilot Ignition System Wiring Wire Size Max. LengthPilot Accessories Appliance SetupDoor Crown Installation Remove Shipping MaterialsPanel Set Installation Grille InstallationBack of TOP Panel Screws Back of Side Panel Retaining Tabs Brick InstallationRear Brick Retaining Tabs Positioning the LogsMineral Wool Blower InstallationIncluded in kit Blower = 1/4 in mm female spade = 1/4 in mm male spade Air Shutter Adjustment Before Lighting Appliance Operating InstructionsLighting Appliance For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingDoor Frame with Glass Assembly Replacement Glass ReplacementMaintaining and Servicing Appliance To Replace Separate Glass PiecesNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramHHT Vent Components ListService Parts Log Set AssemblyDepot Service Parts ListDescription Serial # Part Number Stocked Standing Pilot Valve AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

HUDBAY-INS specifications

Hearth and Home Technologies (HHT) has consistently set the benchmark in the hearth industry with its innovative products. One of its noteworthy offerings is the HUDBAY-INS, a vent-free gas fireplace insert designed to provide unparalleled comfort and efficiency in home heating. The HUDBAY-INS showcases a blend of modern technology, aesthetic appeal, and user-friendly features that cater to the evolving needs of homeowners.

At the heart of the HUDBAY-INS is its advanced vent-free technology. This allows the fireplace insert to operate without the need for flues or chimneys, resulting in an efficient heating solution that maximizes energy use. Homeowners can enjoy the benefits of a warm, inviting space without the complexities associated with traditional vented models. The vent-free design also simplifies installation, making it a versatile option suitable for various home layouts.

One of the standout features of the HUDBAY-INS is its adjustable flame. Users can customize their experience by controlling the height and intensity of the flames, allowing for a cozy ambiance that can be tailored to any occasion. Additionally, the insert is equipped with high-grade ceramic glass that provides both durability and a clear view of the mesmerizing flames, enhancing the visual appeal of any room.

Another important characteristic of the HUDBAY-INS is its safety features. The unit comes with a built-in Oxygen Depletion Sensor (ODS), which ensures that the fireplace will shut off automatically if oxygen levels become too low, providing peace of mind for families. This feature underscores HHT’s commitment to safety in home heating solutions.

Energy efficiency is a key consideration for modern homeowners, and the HUDBAY-INS excels in this area. With its ability to provide warmth without excessive energy consumption, the insert is an eco-friendly choice that aligns with sustainable living practices. It is compatible with various home designs, lending flexibility to those looking to enhance their interiors with functional yet stylish heating solutions.

Durability is another hallmark of the HUDBAY-INS. Constructed with high-quality materials, it promises longevity and reliable performance while also providing a range of customizable finishes to suit individual tastes. Whether one prefers a sleek modern look or a more traditional aesthetic, the HUDBAY-INS can seamlessly integrate into any environment.

In conclusion, the Hearth and Home Technologies HUDBAY-INS represents a perfect synthesis of innovative technology, safety features, and aesthetic versatility. It stands out as an era-defining product that prioritizes user comfort, energy efficiency, and design flexibility, making it an ideal choice for contemporary households seeking effective home heating solutions.