Hearth and Home Technologies HUDBAY-INS owner manual Valve Regulator Replacement

Page 11

With a 5/8 in. wrench remove the orifice retaining nut. Replace with the appropriate orifice (.076 LP / .125 NG).

Figure 6.5

Remove the pilot hood and set aside.

C. Valve Regulator Replacement

Remove upper and lower back shield. Loosen the set col- lars on the extension rods with the 3/32 in. Allen wrench. Remove the rods and adapter cap.

Turn control knob to the OFF position, ensure that gas supply to the valve has been turned off. Using a Torx TH20, or slotted screwdriver, remove the three pressure regulator mounting screws (A), pressure regulator tower (B), and diaphragm (C).

A

B

C

Figure 6.8

Figure 6.6

Note: Do not remove retaining clip from the pilot hood.

Using a 5/32 in. (4 mm) Allen wrench, remove the pilot injector and replace with an appropriate injector (#35 LP / #62 NG).

Figure 6.7

Note: If installing brick also, do so now before reassembling. If not installing brick, reassemble burner in reverse order of removal.

WARNING

Fire Risk.

Explosion Risk.

Disconnect any electrical cords and turn off gas supply to unit before proceeding if converting fuel on an appliance already fully installed.

Quadra-Fire • Hudson Bay Insert • 7008-115 Rev. H • 10/08

11

Image 11
Contents Do Discardnot What to do if you smell gasHUDBAY-INS Welcome to the Quadra-Fire Family Table of Contents Listing and Code Approvals Read all of the instructions before starting the insta Installation to ensure maximum safety and benefitGetting Started Tools and Supplies NeededHearth Framing and ClearancesSelecting Appliance Location Clearances to CombustiblesVent Termination Minimum Clearances Termination LocationsVent Information Venting and InstallationExhaust AIR Vent Pipe Termination CAP Adaptor Screws Nuts Holding Burner PAN Gas InformationFuel Conversions Converting to LP GasValve Regulator Replacement Gas Pressures Check for GAS Leaks Gas ConnectionWire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringPilot Remove Shipping Materials Appliance SetupAccessories Door Crown InstallationBack of TOP Panel Screws Back of Side Panel Grille InstallationPanel Set Installation Retaining Tabs Brick InstallationRear Brick Retaining Tabs Positioning the LogsIncluded in kit Blower Blower InstallationMineral Wool = 1/4 in mm female spade = 1/4 in mm male spade Air Shutter Adjustment Before Lighting Appliance Operating InstructionsLighting Appliance For Your Safety Read Before LightingAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Symptom Possible Cause Corrective Action TroubleshootingTo Replace Separate Glass Pieces Glass ReplacementDoor Frame with Glass Assembly Replacement Maintaining and Servicing ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramHHT Vent Components ListService Parts Log Set AssemblyDescription Serial # Part Number Service Parts ListDepot Stocked Standing Pilot Valve AssemblyCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Contact Information

HUDBAY-INS specifications

Hearth and Home Technologies (HHT) has consistently set the benchmark in the hearth industry with its innovative products. One of its noteworthy offerings is the HUDBAY-INS, a vent-free gas fireplace insert designed to provide unparalleled comfort and efficiency in home heating. The HUDBAY-INS showcases a blend of modern technology, aesthetic appeal, and user-friendly features that cater to the evolving needs of homeowners.

At the heart of the HUDBAY-INS is its advanced vent-free technology. This allows the fireplace insert to operate without the need for flues or chimneys, resulting in an efficient heating solution that maximizes energy use. Homeowners can enjoy the benefits of a warm, inviting space without the complexities associated with traditional vented models. The vent-free design also simplifies installation, making it a versatile option suitable for various home layouts.

One of the standout features of the HUDBAY-INS is its adjustable flame. Users can customize their experience by controlling the height and intensity of the flames, allowing for a cozy ambiance that can be tailored to any occasion. Additionally, the insert is equipped with high-grade ceramic glass that provides both durability and a clear view of the mesmerizing flames, enhancing the visual appeal of any room.

Another important characteristic of the HUDBAY-INS is its safety features. The unit comes with a built-in Oxygen Depletion Sensor (ODS), which ensures that the fireplace will shut off automatically if oxygen levels become too low, providing peace of mind for families. This feature underscores HHT’s commitment to safety in home heating solutions.

Energy efficiency is a key consideration for modern homeowners, and the HUDBAY-INS excels in this area. With its ability to provide warmth without excessive energy consumption, the insert is an eco-friendly choice that aligns with sustainable living practices. It is compatible with various home designs, lending flexibility to those looking to enhance their interiors with functional yet stylish heating solutions.

Durability is another hallmark of the HUDBAY-INS. Constructed with high-quality materials, it promises longevity and reliable performance while also providing a range of customizable finishes to suit individual tastes. Whether one prefers a sleek modern look or a more traditional aesthetic, the HUDBAY-INS can seamlessly integrate into any environment.

In conclusion, the Hearth and Home Technologies HUDBAY-INS represents a perfect synthesis of innovative technology, safety features, and aesthetic versatility. It stands out as an era-defining product that prioritizes user comfort, energy efficiency, and design flexibility, making it an ideal choice for contemporary households seeking effective home heating solutions.