Hearth and Home Technologies Pier-HVB-IPI Locating the Fireplace, Clearance Requirements

Page 14

3Installing the Fireplace

Step 1. Locating the Fireplace

The diagram below shows space and clearance require- ments for locating a fireplace within a room.

Note: Refer to Figure 4B for dimensions and appliance locations if installing a Pier-HVB unit with a Catalina shelf and/or marble package.

 

GLASS

GLASS

 

 

 

PIER-HVB-IPI

 

 

TOP VIEW

 

 

36"

 

 

GLASS

 

 

 

36"

 

 

36"

 

GLASS

 

 

ST-HVB-IPI

 

 

TOP VIEW

 

 

GLASS

 

 

36"

 

Figure 4A.

Fireplace Dimensions and Locations

Note: Refer to the Catalina installation instruction included with kit for assembly and installation.

Note: This location diagram MUST be followed when in- stalling a Pier-HVB with a Catalina shelf/marble package since the fireplace is installed further from finished wall.

FINISHED

WALL

45 -1/4 in. (1149mm)

50-1/2 in.34-1/2 in.

7 in.

47-1/2 in.

13/16 in. 45-1/4 in.

Marble sizes (inches):

Header

26 x 8

Side headers

45-1/2 x 8

Legs

33-1/2 x 7

Figure 4B.

Fireplace Locations/Dimensions with

 

Catalina Shelf/Marble Package ONLY

Clearance Requirements

The top, back, and sides of the fireplace are defined by stand-offs. The minimum clearance to a perpendicular wall extending past the face of the fireplace is one inch (25 mm). The metal ends of the fireplace may NOT be recessed into combustible construction.

14

Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI2006-901 Rev. C • 12/07

Image 14
Contents ST-HVB-IPI Safety and Warning Information Table of Contents Log Assembly Pier-HVB-IPIService Part List PIER-HVB-IPIST-HVB-IPI ST-HVB-IPI IPI Valve Assembly PIER-HVB-IPI, ST-HVB-IPICertification Installation Codes High Altitude InstallationsAppliance Certification Manufacturer Requirements Requirements for the Commonwealth of MassachusettsVent Directly BELOW. Keep Clear of ALL OB- Structions ANY Such Action MAY Possibly Cause a Fire Hazard Pre-install PreparationIntroducing the Heat & Glo Gas Fireplaces Diagram of the PIER-HVB-IPI Diagram of the ST-HVB-IPI Clearance Requirements Fireplace Dimensions and LocationsLocating the Fireplace Framing the Fireplace 787Model AT Each Joint Tems or Components MAY be Used Installing the Vent SystemVent System Approvals Identifying Vent ComponentsStraight OUT Straight UP Vertical VentingMAX .2 M Max. RunVenting with One 90 Elbow Venting with Two 90 Elbows + H1 FT Venting with three 90 elbows + V1 FT + H1 FT Installing Vent Components Attach the First Vent Component to the Starting CollarsInstall Support Brackets Continue Adding Vent ComponentsAttic Firestop Positioned SO That the Arrow is Pointing UPVent Termination Minimum Clearances Minimum Height from Roof to Lowest Discharge Opening Securing of a Fireplace Positioning, Leveling, and Securing the FireplaceGas Control System Fireplace Junction BOX in a IPI SystemGas Supply Line Gas Pressure RequirementsAppliance Requirements Wiring the Fireplace For Intermittent Pilot Ignition WiringOperation using Battery Power Optional Accessories Wall Switch Fan InstallationWall Switch Installation for Fan Optional Use to manually control fan with wall switchHearth Extensions FinishingANY Manner Shutter Settings Installing Trim, Logs & Ember MaterialInstalling the Trim Glass Specifications Model TypeUsing a 5/16 nut driver remove the two bolts see Figure Placing the Ember MaterialBefore Lighting the Fireplace After the InstallationDouble-check for faulty components Lighting the FireplaceFireplace Maintenance Important Turn OFF the GAS Before Servicing Your FireplaceContact Information

Pier-HVB-IPI, ST-HVB-IPI specifications

Hearth and Home Technologies has made significant strides in the fireplace and heating solutions market with their innovative products, including the ST-HVB-IPI and Pier-HVB-IPI models. These high-efficiency fireplaces promise to bring both functionality and aesthetic appeal to any living space.

The ST-HVB-IPI is designed as a versatile, direct vent gas fireplace that maximizes heat output while maintaining an elegant appearance. One of its standout features is the IntelliFire® Ignition System, which ensures safe and reliable ignition while conserving energy. This system allows for easy operation, making it user-friendly for anyone looking to enjoy a cozy fire with minimal hassle.

In terms of design, the ST-HVB-IPI offers a modern, clean aesthetic that can fit seamlessly into various home styles. With customizable options for fronts, media, and finishes, users can personalize their fireplace to match their décor preferences. Additionally, the large viewing area provides an unobstructed view of the flames, enhancing the ambiance of any room.

The Pier-HVB-IPI, on the other hand, serves as a striking centerpiece in spaces with its unique multi-sided design. This model also utilizes the IntelliFire® Ignition System and is engineered for high thermal efficiency, making it a great option for homeowners looking to optimize their heating without sacrificing style. The Pier model allows for installation in various configurations, promoting versatility in home design.

Both models boast exceptional engineering with a focus on performance. They are equipped with a high-efficiency heat exchanger that maximizes heat output while reducing energy consumption. This feature not only keeps living spaces warm but also enhances overall energy efficiency, which is a growing concern among eco-conscious consumers.

Safety is another key priority for Hearth and Home Technologies. Both fireplaces come designed with safety features such as a safety barrier and optional glass doors that help keep children and pets safe while ensuring the fire remains contained.

In conclusion, the ST-HVB-IPI and Pier-HVB-IPI by Hearth and Home Technologies stand at the intersection of modern design and innovative technology. Offering customizable aesthetics, advanced ignition systems, and enhanced safety and efficiency features, these models are exemplary choices for homeowners seeking to elevate their living environments with elegance and warmth.