4Maintaining and Servicing Your Fireplace

Fireplace Maintenance

Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at the beginning of each heating season. See the table below for specific guidelines regarding each fireplace maintenance task.

IMPORTANT: TURN OFF THE GAS BEFORE SERVICING YOUR FIREPLACE.

Replacing old ember material

Frequency: Once annually, during the checkup.

By: Qualified service technician.

Task: Brush away loose ember material near the burner. Replace old ember material with new dime-size and shape pieces of Golden Ember (GE-93) and Glowing Ember (050- 721). New ember material should be placed alternately on top of the burner - a layer of Golden Ember, a layer of Glowing Ember, and so on. Save the remaining ember material and repeat this procedure at your next servicing. For more information, see Placing Ember Material.

Cleaning Burner and Controls Frequency: Once annually. By: Qualified service technician.

Task: Brush or vacuum the control compartment, fireplace logs and burner areas surrounding the logs.

Cleaning Flame Sensor Rod (IPI Systems)

Frequency: Periodically.

By: Qualified service technician.

Task: Make a visual check of the straight flame sensor rod. Use emery cloth to carefully remove any existing white film or deposits.

Checking Flame Patterns, Flame Height

Frequency: Periodically.

By: Qualified service technician/Home owner.

Task: Make a visual check of your fireplace’s flame patterns. Make sure the flames are steady - not lifting or floating. See Figure 47. The flame sensor (IPI) tips should be covered with flame. See Figure 32.

MAKE SURE THE FLAMES

ARE STEADY—NOT

LIFTING OR FLOATING.

Figure 47. Burner Flame Patterns

Checking Vent System

Frequency: Before initial use and at least annually thereafter, more frequently if possible.

By: Qualified service technician/Home owner.

Task: Inspect the external vent cap on a regular basis to ensure that no debris is interfering with the flow of air. Inspect entire vent system for proper function.

Cleaning Glass Door

Frequency: After the first 3 to 4 hours of use. As neces- sary after initial cleaning.

By: Home owner.

Task: Remove and clean glass after the first 3 to 4 hours of use. After the initial cleaning, clean as necessary, particu- larly after adding new ember (flame colorant) material. Film deposits on the inside of the glass door should be cleaned off using a household glass cleaner. NOTE: DO NOT handle or attempt to clean the door when it is hot and DO NOT use abrasive cleaners.

Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI2006-901 Rev. C • 12/07

39

Image 39
Contents ST-HVB-IPI Safety and Warning Information Table of Contents Pier-HVB-IPI Log AssemblyPIER-HVB-IPI Service Part ListST-HVB-IPI ST-HVB-IPI PIER-HVB-IPI, ST-HVB-IPI IPI Valve AssemblyInstallation Codes High Altitude Installations Appliance CertificationCertification Requirements for the Commonwealth of Massachusetts Vent Directly BELOW. Keep Clear of ALL OB- StructionsManufacturer Requirements Pre-install Preparation Introducing the Heat & Glo Gas FireplacesANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the PIER-HVB-IPI Diagram of the ST-HVB-IPI Fireplace Dimensions and Locations Locating the FireplaceClearance Requirements 787 Framing the FireplaceModel AT Each Joint Identifying Vent Components Installing the Vent SystemVent System Approvals Tems or Components MAY be UsedMax. Run Straight UP Vertical VentingMAX .2 M Straight OUTVenting with One 90 Elbow Venting with Two 90 Elbows + H1 FT Venting with three 90 elbows + V1 FT + H1 FT Attach the First Vent Component to the Starting Collars Installing Vent ComponentsContinue Adding Vent Components Install Support BracketsPositioned SO That the Arrow is Pointing UP Attic FirestopVent Termination Minimum Clearances Minimum Height from Roof to Lowest Discharge Opening Fireplace Junction BOX in a IPI System Positioning, Leveling, and Securing the FireplaceGas Control System Securing of a FireplaceGas Pressure Requirements Gas Supply LineWiring the Fireplace For Intermittent Pilot Ignition Wiring Operation using Battery PowerAppliance Requirements Fan Installation Optional Accessories Wall SwitchUse to manually control fan with wall switch Wall Switch Installation for Fan OptionalFinishing ANY MannerHearth Extensions Glass Specifications Model Type Installing Trim, Logs & Ember MaterialInstalling the Trim Shutter SettingsPlacing the Ember Material Using a 5/16 nut driver remove the two bolts see FigureLighting the Fireplace After the InstallationDouble-check for faulty components Before Lighting the FireplaceImportant Turn OFF the GAS Before Servicing Your Fireplace Fireplace MaintenanceContact Information

Pier-HVB-IPI, ST-HVB-IPI specifications

Hearth and Home Technologies has made significant strides in the fireplace and heating solutions market with their innovative products, including the ST-HVB-IPI and Pier-HVB-IPI models. These high-efficiency fireplaces promise to bring both functionality and aesthetic appeal to any living space.

The ST-HVB-IPI is designed as a versatile, direct vent gas fireplace that maximizes heat output while maintaining an elegant appearance. One of its standout features is the IntelliFire® Ignition System, which ensures safe and reliable ignition while conserving energy. This system allows for easy operation, making it user-friendly for anyone looking to enjoy a cozy fire with minimal hassle.

In terms of design, the ST-HVB-IPI offers a modern, clean aesthetic that can fit seamlessly into various home styles. With customizable options for fronts, media, and finishes, users can personalize their fireplace to match their décor preferences. Additionally, the large viewing area provides an unobstructed view of the flames, enhancing the ambiance of any room.

The Pier-HVB-IPI, on the other hand, serves as a striking centerpiece in spaces with its unique multi-sided design. This model also utilizes the IntelliFire® Ignition System and is engineered for high thermal efficiency, making it a great option for homeowners looking to optimize their heating without sacrificing style. The Pier model allows for installation in various configurations, promoting versatility in home design.

Both models boast exceptional engineering with a focus on performance. They are equipped with a high-efficiency heat exchanger that maximizes heat output while reducing energy consumption. This feature not only keeps living spaces warm but also enhances overall energy efficiency, which is a growing concern among eco-conscious consumers.

Safety is another key priority for Hearth and Home Technologies. Both fireplaces come designed with safety features such as a safety barrier and optional glass doors that help keep children and pets safe while ensuring the fire remains contained.

In conclusion, the ST-HVB-IPI and Pier-HVB-IPI by Hearth and Home Technologies stand at the intersection of modern design and innovative technology. Offering customizable aesthetics, advanced ignition systems, and enhanced safety and efficiency features, these models are exemplary choices for homeowners seeking to elevate their living environments with elegance and warmth.