Hearth and Home Technologies Pier-HVB-IPI Pier-Hvb-Ipi, St-Hvb-Ipi, IPI Valve Assembly

Page 8

Service Parts

PIER-HVB-IPI, ST-HVB-IPI

Valve Assembly Parts List

Beginning Manufacturing Date: June 2003

 

Ending Manufacturing Date: ______

IPI Valve Assembly

2

3

 

4

1

5

 

76

8

9

12

 

10

11

 

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts

 

Stocked

 

for your appliance please provide model number and serial number. All parts listed in this

 

 

manual may be ordered from an authorized dealer.

 

 

at Depot

 

 

 

 

 

 

ITEM

DESCRIPTION

SERIAL #

PART NUMBER

 

 

1

Pilot Assembly NG

 

385-510A

Y

 

Pilot Assembly LP

 

385-511A

Y

 

 

 

 

2

Ground Strap

 

385-512

N

 

3

Pilot Support Arm

 

385-120

N

 

4

Pilot Bracket

 

2005-118

N

 

5

Ember Box Assembly

 

2005-114

N

 

6

Flexible Gas Connector

 

2005-009

Y

 

7

Valve Bracket

 

2005-120

N

 

8

Flex Ball Valve Assembly

 

302-320A

Y

 

9

On/Off Switch Assembly

 

060-521A

Y

 

10

Valve NG

 

750-500

Y

 

Valve LP

 

750-501

Y

 

 

 

 

11

Module

 

593-592

Y

 

12

Module Wire Assembly

 

593-590A

Y

 

 

Battery Pack

 

593-594A

Y

 

 

3V Adaptor Plug

 

593-593A

Y

NOTE: Replacement bulbs to be supplied by homeowner. Recommended replacements: Sylvania Mini Candelabra 75 watts.

8

Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI2006-901 Rev. C • 12/07

Image 8
Contents ST-HVB-IPI Safety and Warning Information Table of Contents Log Assembly Pier-HVB-IPIService Part List PIER-HVB-IPIST-HVB-IPI ST-HVB-IPI IPI Valve Assembly PIER-HVB-IPI, ST-HVB-IPICertification Installation Codes High Altitude InstallationsAppliance Certification Manufacturer Requirements Requirements for the Commonwealth of MassachusettsVent Directly BELOW. Keep Clear of ALL OB- Structions ANY Such Action MAY Possibly Cause a Fire Hazard Pre-install PreparationIntroducing the Heat & Glo Gas Fireplaces Diagram of the PIER-HVB-IPI Diagram of the ST-HVB-IPI Clearance Requirements Fireplace Dimensions and LocationsLocating the Fireplace Framing the Fireplace 787Model AT Each Joint Installing the Vent System Vent System ApprovalsTems or Components MAY be Used Identifying Vent ComponentsStraight UP Vertical Venting MAX .2 MStraight OUT Max. RunVenting with One 90 Elbow Venting with Two 90 Elbows + H1 FT Venting with three 90 elbows + V1 FT + H1 FT Installing Vent Components Attach the First Vent Component to the Starting CollarsInstall Support Brackets Continue Adding Vent ComponentsAttic Firestop Positioned SO That the Arrow is Pointing UPVent Termination Minimum Clearances Minimum Height from Roof to Lowest Discharge Opening Positioning, Leveling, and Securing the Fireplace Gas Control SystemSecuring of a Fireplace Fireplace Junction BOX in a IPI SystemGas Supply Line Gas Pressure RequirementsAppliance Requirements Wiring the Fireplace For Intermittent Pilot Ignition WiringOperation using Battery Power Optional Accessories Wall Switch Fan InstallationWall Switch Installation for Fan Optional Use to manually control fan with wall switchHearth Extensions FinishingANY Manner Installing Trim, Logs & Ember Material Installing the TrimShutter Settings Glass Specifications Model TypeUsing a 5/16 nut driver remove the two bolts see Figure Placing the Ember MaterialAfter the Installation Double-check for faulty componentsBefore Lighting the Fireplace Lighting the FireplaceFireplace Maintenance Important Turn OFF the GAS Before Servicing Your FireplaceContact Information

Pier-HVB-IPI, ST-HVB-IPI specifications

Hearth and Home Technologies has made significant strides in the fireplace and heating solutions market with their innovative products, including the ST-HVB-IPI and Pier-HVB-IPI models. These high-efficiency fireplaces promise to bring both functionality and aesthetic appeal to any living space.

The ST-HVB-IPI is designed as a versatile, direct vent gas fireplace that maximizes heat output while maintaining an elegant appearance. One of its standout features is the IntelliFire® Ignition System, which ensures safe and reliable ignition while conserving energy. This system allows for easy operation, making it user-friendly for anyone looking to enjoy a cozy fire with minimal hassle.

In terms of design, the ST-HVB-IPI offers a modern, clean aesthetic that can fit seamlessly into various home styles. With customizable options for fronts, media, and finishes, users can personalize their fireplace to match their décor preferences. Additionally, the large viewing area provides an unobstructed view of the flames, enhancing the ambiance of any room.

The Pier-HVB-IPI, on the other hand, serves as a striking centerpiece in spaces with its unique multi-sided design. This model also utilizes the IntelliFire® Ignition System and is engineered for high thermal efficiency, making it a great option for homeowners looking to optimize their heating without sacrificing style. The Pier model allows for installation in various configurations, promoting versatility in home design.

Both models boast exceptional engineering with a focus on performance. They are equipped with a high-efficiency heat exchanger that maximizes heat output while reducing energy consumption. This feature not only keeps living spaces warm but also enhances overall energy efficiency, which is a growing concern among eco-conscious consumers.

Safety is another key priority for Hearth and Home Technologies. Both fireplaces come designed with safety features such as a safety barrier and optional glass doors that help keep children and pets safe while ensuring the fire remains contained.

In conclusion, the ST-HVB-IPI and Pier-HVB-IPI by Hearth and Home Technologies stand at the intersection of modern design and innovative technology. Offering customizable aesthetics, advanced ignition systems, and enhanced safety and efficiency features, these models are exemplary choices for homeowners seeking to elevate their living environments with elegance and warmth.