Symptom

Possible Cause

Corrective Action

5. The pilot and main

a. No LP in the tank

Check the LP (propane) tank. Refill the

burner extinguish

 

fuel tank.

while in operation.

b. Inner flue pipe

Check for gas leaks.

 

 

leaking exhaust

 

 

gases back into the

 

 

system

 

 

c. Horizontal flue

The horizontal flue cap should slope

 

improperly pitched

down only enough to prevent any water

 

 

from entering the unit. The maximum

 

 

downward slope is 0.6 cm.

 

d. Glass too loose and

Tighten the corner.

 

air tight packet leaks

 

 

in corners after

 

 

usage

 

 

e. Bad thermopile or

Replace if necessary.

 

thermocouple

 

 

f. Improper flue cap

Check for proper installation and

 

installation

freedom from debris or blockage.

 

 

 

6. Glass soots.

a. Flame impingement

Adjust the log set so that the flame

 

 

 

does not excessively impinge on it.

 

b. Improper venturi

Adjust the air shutter at the base of the

 

burner.

 

setting

 

Inspect the opening at the base of the

 

c. Debris around

 

burner. NO MATERIAL SHOULD BE

 

venturi

PLACED IN THIS OPENING.

 

 

 

7. Flame burns blue

a. Insufficient oxygen

Ensure that the flue cap is installed

and lifts off burner.

being supplied

properly and free of debris. Ensure that

 

 

the flue system joints are tight and

 

 

have no leaks.

 

 

Ensure that no debris has been placed

 

 

in the area at the base of, or in the area

 

 

of, the air holes in the center of the

 

 

base pan beneath the burner.

 

 

Ensure that the glass is tightened

 

 

properly on the unit, particularly on top

 

 

corners.

 

 

 

Image 42
Contents 0087 What to do if you smell gasSafety and Warning Information Installing the Fireplace Table of ContentsÎService Parts List Maintaining and Servicing Your Fireplace Troubleshooting6000TRS-CE NG Service Parts List 6000TRS-CEStanding Pilot Description Serial # Part NumberAppliance Certification Installation RegulationsApprovals and Regulations 6000TRS-CE Advantica Gas FireplaceANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the 6000TRS-CE Installing the Fireplace Clearance RequirementsStep Flue System Approvals Identifying Flue ComponentsDVP90ST Straight up Vertical Flue Flue with One 90 Elbow Flue with Two 90 Elbows Flue with TWO 2 90 Elbows Flue with three 90 elbows Flue with three 90 elbows Installing Flue Components Venting Out the Rear FlueVenting Out the Top Flue Install Support Brackets On the TOP of the heaterInstall Firestops For Horizontal Runs Firestops are Required onFlue Pipe & Firestop Flue Termination Arrow is Pointing UP DVP Termination Cap This also pertains to vertical flue systems installed Alcove Applications Step Gas Control System Gas Control SystemStep Gas Supply Line Do not USE AN Open Flame to Check for GAS LeaksStep Wiring Fireplace RequirementsStanding Pilot Ignition Wiring Diagram Step FinishingInstalling the Trim Installing the Ceramic RefractoryLOG Placement Page GlassAssembly Placing the Ember MaterialDouble-check for faulty components Step Before Lighting Fireplace After InstallationReview safety warnings and cautions Double-check for gas leaksFireplace Maintenance Maintaining Servicing Your FireplaceBurner Flame Patterns Standing Pilot Troubleshooting Trouble- shootingCheck the thermopile with a millivolt Placed in this Opening

6000TRS-CE specifications

Hearth and Home Technologies is renowned for producing innovative and efficient heating solutions, and their 6000TRS-CE model exemplifies this commitment to quality and performance. The 6000TRS-CE is a contemporary gas fireplace that combines aesthetic appeal with cutting-edge technology, making it a popular choice for modern homes.

One of the standout features of the 6000TRS-CE is its expansive viewing area. The large glass front allows for maximum visibility of the flames, creating a captivating focal point in any room. This model is designed with a clean, modern aesthetic, ensuring that it seamlessly fits into various interior designs.

In terms of efficiency, the 6000TRS-CE is equipped with a powerful heat exchanger that ensures optimal warmth while minimizing energy consumption. This not only makes it environmentally friendly but also results in lower utility bills for homeowners. The fireplace boasts a high efficiency rating, which underscores its prowess in providing comfortable heating without excessive fuel usage.

The technology integrated into the 6000TRS-CE allows for precise temperature control. With an advanced electronic control system, users can easily adjust settings to their desired levels, making it convenient to maintain the perfect ambiance. The model also features a remote control option, allowing homeowners to operate the fireplace from the comfort of their seating area.

Additionally, the 6000TRS-CE incorporates a realistic flame presentation, achieved through its innovative burner system. This system not only enhances the visual appeal of the flames but also contributes to a more realistic ambiance, emulating the look and feel of a traditional wood-burning fireplace without the hassle of logs and ashes.

The 6000TRS-CE is designed with safety and convenience in mind. It includes a glass enclosure that remains cool to the touch, offering peace of mind for households with children or pets. Furthermore, the fireplace is equipped with safety shut-offs and feature-rich options that enhance user experience while prioritizing safety.

Overall, the Hearth and Home Technologies 6000TRS-CE model combines modern design with efficient performance, ensuring it stands out in the realm of gas fireplaces. With its impressive features, ease of use, and focus on safety, the 6000TRS-CE is an excellent addition to any home looking to enhance its heating solution while maintaining a stylish appearance.