Hearth and Home Technologies 4055-187 For Your Safety Read Before Lighting Lighting Instructions

Page 12

J. Lighting Instructions (Standing Pilot)

For normal use, activate/deactivate your fireplace with the wall switch or remote control.

If your fireplace must be deactivated for service or an extended period of time, follow the instructions below.

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

LIGHTING INSTRUCTIONS

1.Open control access panel.

2. Turn off all electric power to the appliance.

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these in- structions exactly.

B.BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

DO NOT try to light any appliance.

DO NOT touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, DO NOT try to repair it, call a qualified service technician. Force or attempted repair may re- sult in a fire or explosion.

D. DO NOT use this appliance if any part has been under water. Imme- diately call a qualified service tech- nician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

3.Push in gas control knob slightly and turn clockwise

to “OFF”.

Note: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. DO NOT force.

4.Open the fixed glass assembly. You may need to remove the decorative front.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell

gas, STOP! Follow “B” in the Safety Information located on the left side of this label. If you don’t smell gas, go to next step.

6. Find the pilot. The pilot is inside combustion chamber next to the main burner

7. Turn knob on gas control counterclockwise

to “PILOT”.

WARNING: CAUTION:

8. Push in control knob all the way and hold in. Immedi-

ately depress red or black piezo button. It may require

several depressions of the red or black piezo button

until PILOT lights. If PILOT light does not light after

DO NOT CONNECT 110 VAC TO THE CONTROL VALVE.

Improper installation, adjustment, al- teration, service or maintenance can cause injury or property damage. Re- fer to the owner’s information manual provided with this appliance.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

If not installed, operated, and main- tained in accordance with the manu- facturer’s instructions, this product could expose you to substances in fuel or fuel combustion which are known to the State of California to cause can- cer, birth defects, or other reproductive harm.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

Hot while in operation. DO NOT touch. Keep children, clothing, furniture, gaso- line and other liquids having flammable vapors away.

DO NOT operate the appliance with fixed glass assembly removed, cracked or broken. Replacement of the fixed glass assembly should be done by a licensed or qualified service person.

NOT FOR USE

WITH SOLID FUEL

For use with natural gas and propane. A conversion kit, as supplied by the manufacturer, shall be used to convert this appliance to the alternate fuel.

Also Certified for Installation in a Bedroom or a Bedsitting Room.

For assistance or additional informa- tion, consult a qualified installer, ser- vice agency or the gas supplier.

10 seconds, return to step 3. Continue to hold the

control knob in for about one minute after the pilot is

lit. Release knob and it will pop back out. Pilot should

remain lit. If it goes out, repeat steps 3 through 6.

If knob does not pop up when released, stop and

immediately call your service technician or gas

supplier.

If the pilot will not stay lit after several tries, turn

the gas control knob to “OFF” and call your ser-

vice technician or gas supplier.

9. Reinstall fixed glass assembly. Reinstall decorative

front.

10. Turn gas control knob counterclockwise

to “ON”. Close access panel.

11. Turn on all electric power to the appliance.

12. To light burner, turn the wall control or on/off switch

to “ON”.

TO TURN OFF

GAS TO APPLIANCE

1.

Turn off all electric power to the appliance if ser-

 

vice is to be performed.

2.

Open control access panel.

3.

Move switch to “OFF” position.

For additional information on operating your

Hearth & Home Technologies fireplace, please refer to www.fireplaces.com.

Final inspection by

4.

Push in gas control knob slightly and turn clock-

 

wise

to OFF”. DO NOT force.

5.

Close control access panel.

464-903H

12

Heatilator • Novus NDV Series • 4055-187 Rev. V • 1/12

Image 12
Contents Models What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents Troubleshooting Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGas Fireplace Safety Operating InstructionsYour Fireplace Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceLighting Instructions IPI Final inspection byFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotFlame Adjustment Control Frequently Asked QuestionsAfter Appliance is Lit Maintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsEither cobrahead or SIT Getting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Framing and Clearances Select Appliance LocationConstructing the Appliance Chase ClearancesMantel and Wall Projections Mantel Legs or Wall ProjectionsTermination Locations Vent Termination Minimum ClearancesMinimum Clearances for Terminations Vent Information and Diagrams Approved PipeMeasuring Standards Vent Table KeyVent Diagrams Top Vent Horizontal Termination Two 45 ElbowsTop Vent Horizontal Termination One Elbow Two ElbowsInstalled Vertically Install Top Vent Flue Visor No Elbow Configura- tions Top Vent Vertical Termination12 ft 3.66 m min 60 ft 18.29 m max Rear Vent Horizontal Termination DVP only Installed Horizontally Rear Vent Vertical Termination DVP only Min Ft 1.83 m max 12 ft 3.66 m min Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Install the Ceiling Firestop Ceiling firestop Must be used between floors and atticsInstall Attic Insulation Shield Flat Ceiling InstallationAppliance Preparation Top VentRear Vent Secure and Level the Appliance Installing Vent Pipe Assemble Vent Sections DVP onlyAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap Shrouds HHT ShroudsField Constructed Shrouds Mailbox Style Shroud Dimensions Min. Base Dims Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Standing Pilot Ignition System WiringIntellifire Ignition System Wiring Optional Accessories RequirementsElectrical Service and Repair WHTJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Non-combustible Facing Diagram Facing MaterialAppliance Setup Replacing Fixed Glass Assembly Air Shutter SettingPlace the Rockwool Place the Lava RockInstall Hood Install Floor CoverRemove Screen Protector Unpackage the Hood & Floor CoverClose the Screen Assembly Hang Screen on Shoulder ScrewsTroubleshooting Standing Pilot Ignition SystemTroubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Pilot flame has been lit Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45DVP-TRAPFL DVP-TVHW DVP-TRAP Description Part Number  B. Vent Components Diagrams 25-3/16SLP-CCS-BK SLP-TRAP Log Set Assembly Service Parts NDV3630, NDV3630iPart number list on following Service Parts StockedAt Depot Service Parts NDV3933, NDV3933i NDV3933, NDV3933i Service Parts NDV4236, NDV4236i NDV4236, NDV4236i Service Parts NDV4842, NDV4842i NDV4842, NDV4842i #15 Standing Pilot Valve Assembly NDV3630NDV3933 NDV4236#15 IPI Valve Assembly NDV3630I, NDV3933I, NDV4236I, NDV4842IService Parts NDV3630, NDV3933, NDV4236, NDV4842 IPI Conversion KitsOptional Components Model # DescriptionWTB36 Catalog # Contact Information

4055-187 specifications

Hearth and Home Technologies (HHT) has long been a leader in the fireplace and home heating sector, providing innovative solutions that enhance comfort and aesthetics in homes across the globe. One of their standout offerings is the HHT 4055-187 model, which showcases a harmonious blend of functionality and design, making it a highly sought-after option for both new constructions and remodels.

The HHT 4055-187 is a gas fireplace, revered for its efficiency and convenience. One of its main features is the direct vent technology, which allows for safe and efficient venting of combustion gases directly outside. This not only improves the air quality indoors but also enables the fireplace to be installed in virtually any location without the need for a traditional chimney. With its aesthetic appeal, the 4055-187 boasts a customizable design, allowing users to choose from various media options, including pebbles or logs, to personalize their fireplace experience.

In terms of performance, the HHT 4055-187 is engineered for efficiency. It provides a considerable heat output, ensuring rooms are warmed quickly and effectively. The fireplace includes features such as adjustable flame height and temperature control, allowing users to customize their heating experience based on their comfort preferences. The inclusion of an intuitive remote control system further enhances user convenience, enabling effortless adjustments from across the room.

The model's LED lighting also adds a contemporary touch, creating an inviting ambiance even when the fireplace is not in use. The HHT 4055-187 is built with impressive durability, utilizing high-quality materials designed to withstand the rigors of regular use while maintaining its sleek appearance.

Safety features are paramount, making this model an ideal choice for families. The unit includes automatic shut-off mechanisms and tempered glass to protect against accidental contact. Additionally, its innovative design minimizes the risk of accidental fuel leaks, ensuring peace of mind for homeowners.

In summary, the Hearth and Home Technologies 4055-187 is more than just a heating appliance; it is a centerpiece that combines modern technology, aesthetic flexibility, and safety for a truly impressive fireplace experience. Whether you are seeking warmth on a chilly evening or looking to enhance your living space with a focal point, the HHT 4055-187 stands out as a reliable and stylish choice.