Hearth and Home Technologies 4055-187 Troubleshooting, Symptom Possible Cause Corrective Action

Page 60

Troubleshooting (continued)

Symptom

Possible Cause

Corrective Action

3. (Continued)

C. Failed valve.

Turn the valve knob to the ON position. Place the ON/OFF switch

 

 

in the ON position. Check the millivolt meter a the thermopile

 

 

terminals. The millivolt meter should read greater than 125mV. If the

 

 

reading is acceptable, and if the burner does not come on, replace

 

 

the gas valve.

 

 

 

 

D. Plugged burner orifice.

Check the burner orifice for stoppage. Remove stoppage.

 

 

 

 

E. Wall switch or wires.

Check the wall switch and wires for proper connections. Place the

 

 

jumper wires across the terminals at the wall switch. If the burner

 

 

comes on, replace the wall switch. If the wall switch is OK, place

 

 

the jumper wires across the wall switch wires at the gas valve. If the

 

 

burner comes on, the wires are faulty or connections are bad.

 

 

 

4. Frequent pilot outage

A. Pilot flame may be too high or

Clean thermocouple and adjust the pilot flame for proper flame

problem.

too low, or blowing out (high

impingement. Follow lighting instructions carefully.

 

pressure), causing pilot safety

 

 

to drop out.

 

 

 

 

5. The pilot and main

A. No LP in tank.

Check the LP (propane) tank. Refill the fuel tank.

burner extinguish while in

B. Improper gas inlet pressure.

Verify with manometer. NG should read 5-14 inches w.c. LP

operation.

 

should read 10-14 inches w.c.

 

 

 

C. Inner vent pipe leaking exhaust

Check venting system for damage. Replace/repair improperly

 

gases back into the system.

assembled pipe sections.

 

 

 

 

D. Glass installed improperly.

Check to ensure glass is installed properly. Replace glass panel

 

 

assembly.

 

E. Failed thermopile or

Replace pilot if necessary.

 

thermocouple.

 

 

F. Improper vent cap installation.

Check for proper installation and freedom from debris or blockage.

 

 

 

6. Glass soots.

A. Flame impingement.

Adjust the log set so that the flame does not excessively impinge on

 

 

it. Refer to log instructions.

 

B. Improper air shutter setting.

Refer to manual for shutter set points. Ensure that set point is

 

 

correct for appliance/gas type. If unit has adjustable shutter, it may

 

 

be necessary to increase shutter opening.

 

C. Debris around air shutter.

Inspect the opening at the base of the burner. NO MATERIAL

 

 

SHOULD BE PLACED IN THIS OPENING.

7. Flame burns blue and lifts

A. Insufficient oxygen being

Ensure that the vent cap is installed properly and free of debris.

off burner.

supplied.

Ensure that the vent system joints are tight and have no leaks.

 

 

Ensure that no debris has been placed at the base of, or in the area

 

 

of the air holes in the center of the base pan beneath the burner.

 

 

 

 

 

Ensure that the glass is tightened properly on the unit, particularly

 

 

on top corners.

60

Heatilator • Novus NDV Series • 4055-187 Rev. V • 1/12

Image 60
Contents Models What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents Troubleshooting Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGas Fireplace Safety Operating InstructionsYour Fireplace Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceLighting Instructions IPI Final inspection byFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotFlame Adjustment Control Frequently Asked QuestionsAfter Appliance is Lit Maintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsEither cobrahead or SIT Getting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Framing and Clearances Select Appliance LocationConstructing the Appliance Chase ClearancesMantel and Wall Projections Mantel Legs or Wall ProjectionsTermination Locations Vent Termination Minimum ClearancesMinimum Clearances for Terminations Vent Information and Diagrams Approved PipeMeasuring Standards Vent Table KeyVent Diagrams Top Vent Horizontal Termination Two 45 ElbowsTop Vent Horizontal Termination One Elbow Two ElbowsInstalled Vertically Install Top Vent Flue Visor No Elbow Configura- tions Top Vent Vertical Termination12 ft 3.66 m min 60 ft 18.29 m max Rear Vent Horizontal Termination DVP only Installed Horizontally Rear Vent Vertical Termination DVP only Min Ft 1.83 m max 12 ft 3.66 m min Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Install the Ceiling Firestop Ceiling firestop Must be used between floors and atticsInstall Attic Insulation Shield Flat Ceiling InstallationAppliance Preparation Top VentRear Vent Secure and Level the Appliance Installing Vent Pipe Assemble Vent Sections DVP onlyAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap Shrouds HHT ShroudsField Constructed Shrouds Mailbox Style Shroud Dimensions Min. Base Dims Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Standing Pilot Ignition System WiringIntellifire Ignition System Wiring Optional Accessories RequirementsElectrical Service and Repair WHTJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Non-combustible Facing Diagram Facing MaterialAppliance Setup Replacing Fixed Glass Assembly Air Shutter SettingPlace the Rockwool Place the Lava Rock Install Hood Install Floor Cover Remove Screen Protector Unpackage the Hood & Floor CoverClose the Screen Assembly Hang Screen on Shoulder ScrewsTroubleshooting Standing Pilot Ignition SystemTroubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Pilot flame has been lit Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45DVP-TRAPFL DVP-TVHW DVP-TRAP Description Part Number  B. Vent Components Diagrams 25-3/16SLP-CCS-BK SLP-TRAP Log Set Assembly Service Parts NDV3630, NDV3630iPart number list on following Service Parts StockedAt Depot Service Parts NDV3933, NDV3933i NDV3933, NDV3933i Service Parts NDV4236, NDV4236i NDV4236, NDV4236i Service Parts NDV4842, NDV4842i NDV4842, NDV4842i #15 Standing Pilot Valve Assembly NDV3630NDV3933 NDV4236#15 IPI Valve Assembly NDV3630I, NDV3933I, NDV4236I, NDV4842IService Parts NDV3630, NDV3933, NDV4236, NDV4842 IPI Conversion KitsOptional Components Model # DescriptionWTB36 Catalog # Contact Information