Hearth and Home Technologies 4055-187 Vent Information and Diagrams, Approved Pipe, Use of Elbows

Page 24

7 Vent Information and Diagrams

A. Approved Pipe

This appliance is approved for use with Hearth & Home Technologies DVP and SLP venting systems. Refer to Sec- tion 17.B for vent component information.

DO NOT mix pipe, fittings or joining methods from different manufacturers.

The pipe is tested to be run inside an enclosed wall. There is no requirement for inspection openings at each joint within the wall.

WARNING! Risk of Fire or Asphyxiation. This appliance requires a separate vent. DO NOT vent to a pipe serving a separate solid fuel burning appliance.

D. Measuring Standards

Vertical and horizontal measurements listed in the vent diagrams were made using the following standards.

Pipe measurements are shown using the effective length of pipe (see Figure 7.2).

Measurements are made from the appliance outer wrap, not from the standoffs.

Horizontal terminations are measured to the outside mounting surface (flange of termination cap) (see Figure 6.5).

Vertical terminations are measured to bottom of termination cap.

Horizontal pipe installed level with no rise.

B. Vent Table Key

The abbreviations listed in this vent table key are used in the vent diagrams.

Symbol

Description

 

 

V1

First section (closest to appliance) of vertical length

 

 

V2

Second section of vertical length

 

 

H1

First section (closest to appliance) of horizontal length

 

 

H2

Subsequent sections of horizontal length

 

 

C. Use of Elbows

Diagonal runs have both vertical and horizontal vent aspects when calculating the effects. Use the rise for the vertical aspect and the run for the horizontal aspect (see Figure 7.1).

Two 45º elbows may be used in place of one 90º elbow. On 45º runs, one foot of diagonal is equal to 8-1/2 (216 mm) inches horizontal run and 8-1/2 (216 mm) inches vertical run. A length of straight pipe is allowed between two 45º elbows (see Figure 7.1).

Vertical

in.1/2

-8

8-1/2 in.

Horizontal

Figure 7.1

 

Effective Height/Length

 

Pipe

inches

mm

 

DVP4

4

102

Effective

DVP6

6

152

DVP12

12

305

Height/Length

DVP24

24

610

 

DVP36

36

914

 

DVP48

48

1219

 

DVP6A

3 - 6

76 - 152

 

DVP12A

3 - 12

76 - 305

DVP Pipe

 

 

 

(see chart)

 

 

 

 

Effective Height/Length

 

Pipe

inches

mm

Effective

SLP4

4

102

SLP6

6

152

Height/Length

SLP12

12

305

 

SLP24

24

610

 

SLP36

36

914

 

SLP48

48

1219

SLP Pipe

SLP6A

2 - 6

51 - 152

SLP12A

2 - 12

51 - 305

(see chart)

 

 

 

Figure 7.2 Pipe Effective Length

24

Heatilator • Novus NDV Series • 4055-187 Rev. V • 1/12

Image 24
Contents Models What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents Troubleshooting Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGas Fireplace Safety Operating InstructionsYour Fireplace Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceLighting Instructions IPI Final inspection byFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotFlame Adjustment Control Frequently Asked QuestionsAfter Appliance is Lit Maintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsEither cobrahead or SIT Getting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Framing and Clearances Select Appliance LocationConstructing the Appliance Chase ClearancesMantel and Wall Projections Mantel Legs or Wall ProjectionsTermination Locations Vent Termination Minimum ClearancesMinimum Clearances for Terminations Vent Information and Diagrams Approved PipeMeasuring Standards Vent Table KeyVent Diagrams Top Vent Horizontal Termination Two 45 ElbowsTop Vent Horizontal Termination One Elbow Two ElbowsInstalled Vertically Install Top Vent Flue Visor No Elbow Configura- tions Top Vent Vertical Termination12 ft 3.66 m min 60 ft 18.29 m max Rear Vent Horizontal Termination DVP only Installed Horizontally Rear Vent Vertical Termination DVP only Min Ft 1.83 m max 12 ft 3.66 m min Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Install the Ceiling Firestop Ceiling firestop Must be used between floors and atticsInstall Attic Insulation Shield Flat Ceiling InstallationAppliance Preparation Top VentRear Vent Secure and Level the Appliance Installing Vent Pipe Assemble Vent Sections DVP onlyAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap Shrouds HHT ShroudsField Constructed Shrouds Mailbox Style Shroud Dimensions Min. Base Dims Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Standing Pilot Ignition System WiringIntellifire Ignition System Wiring Optional Accessories RequirementsElectrical Service and Repair WHTJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Non-combustible Facing Diagram Facing MaterialAppliance Setup Replacing Fixed Glass Assembly Air Shutter SettingPlace the Rockwool Place the Lava RockInstall Hood Install Floor CoverRemove Screen Protector Unpackage the Hood & Floor CoverClose the Screen Assembly Hang Screen on Shoulder ScrewsTroubleshooting Standing Pilot Ignition SystemTroubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Pilot flame has been lit Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45DVP-TRAPFL DVP-TVHW DVP-TRAP Description Part Number  B. Vent Components Diagrams 25-3/16SLP-CCS-BK SLP-TRAP Log Set Assembly Service Parts NDV3630, NDV3630iPart number list on following Service Parts StockedAt Depot Service Parts NDV3933, NDV3933i NDV3933, NDV3933i Service Parts NDV4236, NDV4236i NDV4236, NDV4236i Service Parts NDV4842, NDV4842i NDV4842, NDV4842i #15 Standing Pilot Valve Assembly NDV3630NDV3933 NDV4236#15 IPI Valve Assembly NDV3630I, NDV3933I, NDV4236I, NDV4842IService Parts NDV3630, NDV3933, NDV4236, NDV4842 IPI Conversion KitsOptional Components Model # DescriptionWTB36 Catalog # Contact Information

4055-187 specifications

Hearth and Home Technologies (HHT) has long been a leader in the fireplace and home heating sector, providing innovative solutions that enhance comfort and aesthetics in homes across the globe. One of their standout offerings is the HHT 4055-187 model, which showcases a harmonious blend of functionality and design, making it a highly sought-after option for both new constructions and remodels.

The HHT 4055-187 is a gas fireplace, revered for its efficiency and convenience. One of its main features is the direct vent technology, which allows for safe and efficient venting of combustion gases directly outside. This not only improves the air quality indoors but also enables the fireplace to be installed in virtually any location without the need for a traditional chimney. With its aesthetic appeal, the 4055-187 boasts a customizable design, allowing users to choose from various media options, including pebbles or logs, to personalize their fireplace experience.

In terms of performance, the HHT 4055-187 is engineered for efficiency. It provides a considerable heat output, ensuring rooms are warmed quickly and effectively. The fireplace includes features such as adjustable flame height and temperature control, allowing users to customize their heating experience based on their comfort preferences. The inclusion of an intuitive remote control system further enhances user convenience, enabling effortless adjustments from across the room.

The model's LED lighting also adds a contemporary touch, creating an inviting ambiance even when the fireplace is not in use. The HHT 4055-187 is built with impressive durability, utilizing high-quality materials designed to withstand the rigors of regular use while maintaining its sleek appearance.

Safety features are paramount, making this model an ideal choice for families. The unit includes automatic shut-off mechanisms and tempered glass to protect against accidental contact. Additionally, its innovative design minimizes the risk of accidental fuel leaks, ensuring peace of mind for homeowners.

In summary, the Hearth and Home Technologies 4055-187 is more than just a heating appliance; it is a centerpiece that combines modern technology, aesthetic flexibility, and safety for a truly impressive fireplace experience. Whether you are seeking warmth on a chilly evening or looking to enhance your living space with a focal point, the HHT 4055-187 stands out as a reliable and stylish choice.