TROUBLE
,,,, ,,,,,,, L ,,,,,_l,
1.Unitwill not run, or will notshutoff.
2.Water runsout of hole in the water levellabel on the front of the unit.
3.Unitwill not dry out completely,
4.Unit will notcycle (Turnoft')when out of water.
5.Filter does not float.
_:_ PROBABLE CAUSE
".Switch Actuator(F!oat) not free to work properly.
,,Too much water.
•Switchactuator ring is not in place.
•High humidityor low temperature resultingin slow
evaporation.
, | , i , i ,ll | ,,,,, | L,u |
•Roat is hung up, or holder is noton the filtertracks.
................,,,,,,,,,,,,
•Roat may have leak,.
•Cardboard packingpiece between motorsupportand filterholder.
ii i , iii 1/ _, III,,H,Ill
i | III | I111 | IH | II | ILl |
REMEDY
,,w,u
•Remove shippingrubber band or unhook switch
actuator dng. (Figure 7).
•Check FULL label in tank. Do not overfill.
°Connect switchactuator ring. See instructions(page 7,
Figure 7).
°Allow unitto continuerunning untilreservoirbecomes dry.
,i,J
°Check float (page 7, Figure
9).
•Remove filterholder, install on filtertracks (page 8,
Figure 10).
.... | H, ,i |
•Check float for leak, replace if
necessary. °Remove cardboard.
............................CAUTION
Use only
Under no circumstances should you use water treatment products designed for Roto belt or Ultrasonic humidifiers.
..... | ft | i | i i,,iL |