Sears 153.33651I, T53, 33631I Installation in ructions, Temperature-Pressure Relief Valve

Page 12

installation in: :ructions

Temperature-Pressure Relief Valve

_WARNING

At the time of manufacture this water heater was provided with a combination temperature-pressures relief valve certi-

fied by a nationally recognized testing laboratory that main-

tains periodic inspection of production of listed equipment or materials, as meeting the requirements for Relief Valves and

Automatic Gas Shutoff Devices for Hot Water Supply Systems, and the latest edition of ANSI Z21.22 and the code

requirements of ASME. If replaced, the valve must meet the requirements of local codes, but not lessthan a combination temperature and pressure relief valve certified as meeting the requirements for Relief Valves and Automatic Gas

Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22

by a nationally recognized testing laboratory that maintains

_eriodic inspection of production of listed equipment or materials.

The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 Ibs./sq. in.) and a discharge capacity not lessthan the water heater input rate as shown on the model rating plate. (Electric heaters - watts divided by 1000 x 3415 equal BTU/Hr. rate.)

Your local jurisdictional authority, while mandating the use of

a temperature-pressure relief valve complying with ANSI Z21.22 and ASME, may require a valve model different from the one furnished with the water heater.

Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a locally )rescribed temperature-pressure relief valve installed in the

designated opening in the water heater in place of the facto- ry furnished valve.

For safe operation of the water heater, the relief valve must not be removed from it'sdesignated opening or plugged.

The temperature.pressure relief valve must be installed

directly into the fitting of the water heater designated for the relief valve. Position the valve downward and provide tubing

so that any discharge will exit only within 6 inches above, or at any distance below the structural floor. Be certain that no

contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any

circumstances. Excessivelength, over 30 feet, or use of more than four elbows can cause restriction and reduce the dis-

charge capacity of the valve.

No valve or other obstruction is to be placed between the relief valve and the tank. Do nut connect tubing directly to discharge drain unless a 6" air gap is provided. To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connect- ed to a drain or other suitable means, the water flow may cause property damage.

The Discharge Pipe:

Must not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions.

Must not be plugged or blocked.

Must be of material listed for hot water distribution.

°Must be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the discharge pipe.

,Must terminate at an adequate drain.

,Must not have any valve between the retlef vane and tank.

(cont'd)

AWARNING

The temperature-pressure relief valve must be manually operated at least once a year. Caution should be taken to ensure that (I) no one is in front of or around the outlet of the temperature.pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot.

if after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining

instructions, and replace the temperature-pressure relief valve with a new one.

HOT

COLD

 

SHUTOFF

 

VALVE

HOT COLD

F-- T E _II_s_RUER E-

RELIEF VALVE

_ DISCHARGE PiPE

(Do no_cap or plug)

6" AIR GAP

FLOOR DP,_IN_ f

RELIEFVALVEOPENING

At the time ot manufacture, this water heater was provided with a combination tem- perature-pressure relief vaIvelisted as complyingwitl_ the standard for relief valves and automatic gas shut-off devices for hot water supply syssems, ANSI Z2L22. For safe

operationof thewaterheater,thereliefvalvemustnotberemovedfromitsdesignated

point of installation or plugged.

Yourlocaljurisdictionalauthority,while mandatingthe use ofa temperature-pressure

relief valve complying with ANSI Z2 I_22 and ASME, may require avalve model different from the one furnished with the water heate_

Compliance with such local requirements must be satisfied by the installer or end user ....

of the water heater with a locally prescribed temperature-pressure relief valve insmlle_ in the designated opening in the water heater.

Seemanual heading -"Temperature-Pressure Relief Vafves'_ for installation and mainte- I

nanceof relief valve,discharge line, and other safetyprecautions,

I

 

12

Image 12
Contents For Your Safety OwnersWater Heater What to do if YOU Smell GASSafety recautions Water Heaters Equipped for ONE Type GASSafety Precautions Safety Precautions Contents Roduct CustomerponsibilitiesWhen Sweat Soldering Ateriais and Basic Tools NeededBasic Tools Additional Tools NeededInstallation Instructions Removing the Old Water HeaterInstallation Instructions contd Acts to Consider About LocationContd Combustion Air and Ventilation for Appliances LocatedInstallation Completed Using Sears Installation KIT Nater PipingInstallation in ructions Temperature-Pressure Relief ValveInstallation instructions contd VentingInstallation instructions Venting contdGas Piping Installation Instructions Sedihent TrapInstallation Checklist Before Lighting the PilotModel Rating Plate Operating Instructions LightingCheck for Leaks Operating Instructions contd Whattodo if YousmellgasNot Force Temperature Regulation Service and Adjustment Venting System inspectionBurner Inspection Service and Adjustment contd Temperature-Pressure Relief Valve OperationService HousekeepingStart Up Conditions Strange SoundsFroubleshooting Guide ContdOperational Conditions CondensationTroubleshooting Guide contd Operational Conditions contdNot Enough or no HOT Water Leakage Checkpoints Page Page Parts rder List Parts rder List contd 153.336150 30 GalParts Order List contd #51 HA Warranty
Related manuals
Manual 108 pages 63.66 Kb

153.33651I, 33631I, 153.33655, 153.3368I1, 153.33625 specifications

Sears, an iconic American retailer, has undergone significant transformations and challenges throughout its history. One of its noteworthy products is the model number 153.514090.16, which represents a particular item in the extensive catalog of goods that Sears has offered over the decades.

The model 153.514090.16 is a home appliance, specifically a powerful and efficient space heater designed to provide warmth and comfort in residential settings. Its main features include a robust heating element that ensures rapid heat distribution throughout a room, making it an ideal choice for colder climates or drafty spaces.

One of the standout characteristics of this model is its adjustable thermostat, allowing users to set their desired temperature for optimal comfort. The heater also comes equipped with multiple heat settings, giving users the flexibility to customize the output based on their needs, whether it's a chilly evening or a moderate day.

The 153.514090.16 design emphasizes safety, incorporating features such as an automatic shut-off mechanism that activates when the unit is tipped over or reaches an unsafe temperature. This focus on safety reflects Sears' commitment to providing reliable and secure home appliances to its customers.

In terms of technology, this model incorporates energy-efficient technology that helps reduce electricity consumption while providing effective heating. This modern approach aligns with the increasing consumer demand for environmentally friendly appliances, making it a popular choice among energy-conscious households.

The construction of the 153.514090.16 includes durable materials that are designed to withstand the rigors of daily use while maintaining a sleek and contemporary aesthetic. Its compact size allows for easy placement in various locations, whether it’s a bedroom, living room, or even a workspace.

Sears has a rich history of delivering quality products across a wide range of categories, and model 153.514090.16 is a testament to its legacy of innovation and customer satisfaction. The integration of user-friendly features, safety precautions, and energy-efficient technology makes this space heater a valuable addition to any home.

As consumers continue to seek reliable and efficient heating solutions, the Sears 153.514090.16 stands as an example of the brand’s commitment to meeting the changing needs of its clientele in an ever-evolving marketplace.