Sears 153, T53, 33631I, 336350 30 GAL Installation instructions, Venting contd, Gas Piping

Page 14

Installation instructions

Venting (cont'd)

MI vent gases must be completely vented to the outdoors of the structure (dwelling). Install only the draft hood provided with the new water heater and no other draft hood.

Vent pipes must be secured at each joint with sheet metal

screws.

 

 

TO

_i

 

HIHNEY

_===_ RISE PER LINEAR

 

 

FOOT

 

 

7

 

VENT

PIPE INSTALLATION

 

(cont'd)

Gas Piping

j&WARNING

Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inches water column ½ pound per square inch (3.5kPa). The minimum inlet gas pressure listed on the model rating

plate is for the purpose of input adjustment.

AWARNING

!if the gas control valve is subjected to pressures exceeding ½ pound per square inch (33kPa), the damage to the gas con- tret valve could result in a fire or explosion from [ealdng gas.

There must be a minimum of 6" clearance between single wall vent ppi e and any combustible materia!. Fill and seal any clear- ance between single wall vent pipe and combustible material with mortar mix, cement, or other noncombustible substance. For other than single wall, follow vent pipe manufacturer's clear- ance specifications. To insure a tight fit of the vent pipe in a brick chimney, seal around the vent pipe with mortar mix cement.

AWARNING

Failure to have required clearances between vent piping and combustible material will result in a fire hazard.

AWARNING

Be sure vent pipe is properly connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation.

AWARNING

Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach, and process chemicals are typical compoundswhich are potentially corrosive.

AWARNING

If the main gas line shutoff serving aU gas appliances is used, also turn "OFF" the gas at each appliance. Leave all gas appli- ances shut off until the water heater installation is complete.

A gas line of sufficient size must be run to the water heater. Consult the latest edition of National Fuel Gas Code ANSI

Z223.1, also referred to as NFPA54 and the gas company con_ cernir_g pipe size.

There must be:

A readily accessible manual shut offwJve in the gas supply line serving the water heater, and

A drip leg (sediment trap) ahead of the gas control valve to help

prevent dirt and foreign materials from entering the gas control

ValVe.

A flexible gas connector or a ground joint union between the shutoffvalve and control valve to permit servidng of the unit,

Be sure to check all the gas piping for leaks befbre lighting the water heater. Use a soapy water solution, not a match or open flame. Rinse offsoapy solution and wipe dry.

Standard Models are for installation up to 3,300 feet above sea level.

Iilgh Altitude Models are for installation from 3,300 to 5,500 feet above sea level.

Ifa standard modd is installed above 3,300 feet or a high altitude model is installed above 5,500 feet, the input rating must be reduced at the rate of 4 percent for each 1,000 feet above sea level.

Contact your local Sears Service Center or gas utility for further informafioo.

14

Image 14
Contents Water Heater For Your SafetyOwners What to do if YOU Smell GASSafety recautions Water Heaters Equipped for ONE Type GASSafety Precautions Safety Precautions Contents Roduct CustomerponsibilitiesBasic Tools When Sweat SolderingAteriais and Basic Tools Needed Additional Tools NeededInstallation Instructions Removing the Old Water HeaterInstallation Instructions contd Acts to Consider About LocationContd Combustion Air and Ventilation for Appliances LocatedInstallation Completed Using Sears Installation KIT Nater PipingInstallation in ructions Temperature-Pressure Relief ValveInstallation instructions contd VentingGas Piping Installation instructionsVenting contd Installation Instructions Sedihent TrapModel Rating Plate Installation ChecklistBefore Lighting the Pilot Check for Leaks Operating InstructionsLighting Not Force Operating Instructions contdWhattodo if Yousmellgas Temperature Regulation Burner Inspection Service and AdjustmentVenting System inspection Service Service and Adjustment contdTemperature-Pressure Relief Valve Operation HousekeepingStart Up Conditions Strange SoundsOperational Conditions Froubleshooting GuideContd CondensationNot Enough or no HOT Water Troubleshooting Guide contdOperational Conditions contd Leakage Checkpoints Page Page Parts rder List Parts rder List contd 153.336150 30 GalParts Order List contd #51 HA Warranty
Related manuals
Manual 108 pages 63.66 Kb

153.33651I, 33631I, 153.33655, 153.3368I1, 153.33625 specifications

Sears, an iconic American retailer, has undergone significant transformations and challenges throughout its history. One of its noteworthy products is the model number 153.514090.16, which represents a particular item in the extensive catalog of goods that Sears has offered over the decades.

The model 153.514090.16 is a home appliance, specifically a powerful and efficient space heater designed to provide warmth and comfort in residential settings. Its main features include a robust heating element that ensures rapid heat distribution throughout a room, making it an ideal choice for colder climates or drafty spaces.

One of the standout characteristics of this model is its adjustable thermostat, allowing users to set their desired temperature for optimal comfort. The heater also comes equipped with multiple heat settings, giving users the flexibility to customize the output based on their needs, whether it's a chilly evening or a moderate day.

The 153.514090.16 design emphasizes safety, incorporating features such as an automatic shut-off mechanism that activates when the unit is tipped over or reaches an unsafe temperature. This focus on safety reflects Sears' commitment to providing reliable and secure home appliances to its customers.

In terms of technology, this model incorporates energy-efficient technology that helps reduce electricity consumption while providing effective heating. This modern approach aligns with the increasing consumer demand for environmentally friendly appliances, making it a popular choice among energy-conscious households.

The construction of the 153.514090.16 includes durable materials that are designed to withstand the rigors of daily use while maintaining a sleek and contemporary aesthetic. Its compact size allows for easy placement in various locations, whether it’s a bedroom, living room, or even a workspace.

Sears has a rich history of delivering quality products across a wide range of categories, and model 153.514090.16 is a testament to its legacy of innovation and customer satisfaction. The integration of user-friendly features, safety precautions, and energy-efficient technology makes this space heater a valuable addition to any home.

As consumers continue to seek reliable and efficient heating solutions, the Sears 153.514090.16 stands as an example of the brand’s commitment to meeting the changing needs of its clientele in an ever-evolving marketplace.