Sears 33631I, T53, 153, 336350 30 GAL Safety recautions, Water Heaters Equipped for ONE Type GAS

Page 2

Safety recautions

_WARNING

Improper installation, adjustment, ateration, service or

maintenance can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Refer to this manu-

al for assistance or consult your local Sears Service Center for further information.

AWARNING

WATER HEATERS EQUIPPED FOR ONE TYPE GAS

ONLY: This water heater is equipped for one type gas only. Check the model rating plate near the gas control valve for the correct gas. DO NOT USE THIS WATER

HEATER WITH ANY GAS OTHER THAN THE ONE SHOWN ON THE MODEL RATING PLATE. Failure to

use the correct gas can cause problems which can result in

DEATH, SERIOUS BODILY INJURY, OR PROPERTY

DAMAGE. if you have any questions or doubts consult your gas supplier or local utility.

AWARNING

INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQ-

UIDS (VAPORS) ARE LIKELY TO BE PRESENT OR STORED (GARAGES, STORAGE, AND UTILITY AREAS,

ETC): Flammable tiquids (such as gasoline, solvents, propane (LP) or butane, etc.), all of which emit flammable vapors, may be improperly stored or used in such areas.

The gas water heater pilot light or main burner can ignite such vapors. The resulting flashback and fire can cause death or serious burns to anyone in the area, as well as

property damage.

If installation in such areas is your only option, then the installation must be accomplished in a way that the pilot flame and main burner flame are elevated from the floor _t least 18 inches. While this may reduce the chances of

flammable vapors from a floor spill being ignited, gasoline and other flammable substances should never be stored or

used in the same room or area containing a gas water heater or other open flame or spark producing appliance. NOTE: Flammable vapors may be drawn by air currents from other areas of the structure to the appliance.

_WARNING

If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries

with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that com-

bustion and ventilation air be taken from outside these

areas. Refer to the "Locating The New Water Heater" section of this manual and also the latest edition of the

National Fuel Gas Code, ANS! Z223.1, also referred to as NFPA 54 for specifics provided concerning air required.

AWARNING

A fire can start if combustible materials such as clothing, cleaning materials, or flammable liquids are placed against or next to the water heater.

_WARNING

At the time of manufacture this water heater was pro-

vided with a combination temperature-pressures relief valve certified by a nationally recognized testing labora- tory that maintains periodic inspection of production of listed equipment or materials, as meeting the require-

ments for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, and the latest

edition of ANSI Z21.22 and the code requirements of ASME. If replaced, the valve must meet the require- ments of local codes, but not less than a combination temperature and pressure relief valve certified as meet-

ing the requirements for Relief Valves and Automatic

Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22 by a nationally recognized testing laborato- ry that maintains periodic inspection of production of listed equipment or materials.

The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (I 50 Ibs./sq. in.) and a discharge capacity not less than the water heater input rate as shown on the model rating plate. (Electric heaters - watts divided by 1000 x 3415 equal BTU/Hr. rate.)

Your local jurisdictional authorlty_ while mandating the

use of a temperature-pressure relief valve complying with ANSI Z21.22 and ASME, may require a valve model different from the one furnished with the water heater.

Compliance with such local requirements must be satis- fied by the installer or end user of the water heater with

a locally prescribed temperature-pressure relief valve installed in the designated opening in the water heater in _lace of the factory furnished valve.

For safe operation of the water heater, the relief valve must not be removed from it'sdesignated opening or plugged.

The temperature-pressure relief valve must be installed directly into the fitting of the water heater designated for the relief valve. Position the valve downward and provide

tubing so that any discharge will exit only within 6 inches above, or at any distance below the structural floor. Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or

reduced in size under any circumstances. Excessive length, over 30 feet, or use of more than four elbows can

cause restriction and reduce the discharge capacity of the valve.

No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge drain unless a 6" air gap is provided. To prevent bodily injury, hazard to llfe, or property dam- age, the relief valve must be allowed to discharge water in quantities should circumstances demand, if the dis- charge pipe is not connected to a drain or other suitable means, the water flow may cause property damage.

The Discharge Pipe:

Must not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions.

Must not be plugged or blocked.

Must be of material listed for hot water distribution.

Must be installed so as to allow complete drainage of

both the temperature-pressure relief valve, and the_"

Must terminate at an adequate drain.

Must not have any valve between the relief valve and

discharge pipe.I tank.

Image 2
Contents Water Heater For Your SafetyOwners What to do if YOU Smell GASSafety recautions Water Heaters Equipped for ONE Type GASSafety Precautions Safety Precautions Contents Roduct CustomerponsibilitiesBasic Tools When Sweat SolderingAteriais and Basic Tools Needed Additional Tools NeededInstallation Instructions Removing the Old Water HeaterInstallation Instructions contd Acts to Consider About LocationContd Combustion Air and Ventilation for Appliances LocatedInstallation Completed Using Sears Installation KIT Nater PipingInstallation in ructions Temperature-Pressure Relief ValveInstallation instructions contd VentingGas Piping Installation instructionsVenting contd Installation Instructions Sedihent TrapModel Rating Plate Installation ChecklistBefore Lighting the Pilot Check for Leaks Operating InstructionsLighting Not Force Operating Instructions contdWhattodo if Yousmellgas Temperature Regulation Burner Inspection Service and AdjustmentVenting System inspection Service Service and Adjustment contdTemperature-Pressure Relief Valve Operation HousekeepingStart Up Conditions Strange SoundsOperational Conditions Froubleshooting GuideContd CondensationNot Enough or no HOT Water Troubleshooting Guide contdOperational Conditions contd Leakage Checkpoints Page Page Parts rder List Parts rder List contd 153.336150 30 GalParts Order List contd #51 HA Warranty
Related manuals
Manual 108 pages 63.66 Kb

153.33651I, 33631I, 153.33655, 153.3368I1, 153.33625 specifications

Sears, an iconic American retailer, has undergone significant transformations and challenges throughout its history. One of its noteworthy products is the model number 153.514090.16, which represents a particular item in the extensive catalog of goods that Sears has offered over the decades.

The model 153.514090.16 is a home appliance, specifically a powerful and efficient space heater designed to provide warmth and comfort in residential settings. Its main features include a robust heating element that ensures rapid heat distribution throughout a room, making it an ideal choice for colder climates or drafty spaces.

One of the standout characteristics of this model is its adjustable thermostat, allowing users to set their desired temperature for optimal comfort. The heater also comes equipped with multiple heat settings, giving users the flexibility to customize the output based on their needs, whether it's a chilly evening or a moderate day.

The 153.514090.16 design emphasizes safety, incorporating features such as an automatic shut-off mechanism that activates when the unit is tipped over or reaches an unsafe temperature. This focus on safety reflects Sears' commitment to providing reliable and secure home appliances to its customers.

In terms of technology, this model incorporates energy-efficient technology that helps reduce electricity consumption while providing effective heating. This modern approach aligns with the increasing consumer demand for environmentally friendly appliances, making it a popular choice among energy-conscious households.

The construction of the 153.514090.16 includes durable materials that are designed to withstand the rigors of daily use while maintaining a sleek and contemporary aesthetic. Its compact size allows for easy placement in various locations, whether it’s a bedroom, living room, or even a workspace.

Sears has a rich history of delivering quality products across a wide range of categories, and model 153.514090.16 is a testament to its legacy of innovation and customer satisfaction. The integration of user-friendly features, safety precautions, and energy-efficient technology makes this space heater a valuable addition to any home.

As consumers continue to seek reliable and efficient heating solutions, the Sears 153.514090.16 stands as an example of the brand’s commitment to meeting the changing needs of its clientele in an ever-evolving marketplace.