1.Pull Pinnacle away from wall. DISCONNECT POWER FROM THE UNIT. Remove lower back panel.

2.Remove the 4 screws holding contactor box cover (bottom rear of unit). The box

will now pivot on hinges. Also remove the 4 screws holding the original safety circuit box on the back of the lower frame.

Contactor Box

Original Safety Box

3.Remove leads LD1 and LD2 from transformer 1, located in contactor box. These are the piggybacked connections. Remove the labeled terminals from the piggybacks and replace in their original positions.

Place TX1-LD1 and TX1-LD2 back on transformers.

Use same location from placement.

Remove piggybacked wires and leads from transformer.

Publication Number: 629088480INS

- 2 -

© 2005, IMI Cornelius Inc.

Image 2
Contents Description QtyInstallation Instructions Publication Number 629088480INS Place template, as shown, between frame and hoses Feed the remaining 4 wires 2 red, 2 orange through hole Disconnect wires here Remove wire tie, if present Check CorrectIncorrect Route extra wire back into unit Protection harnesses Make Sure this is the Board Terminal Labeled P4