2 — Thermostat will control the W1 and O/W2/B outputs. Default is 1.

Option 33 — Single or Two−Piece Installation

This configuration allows the thermostat to compensate for the amount of heat generated by the thermostat electronics to allow more accurate sensing of the temperature sensor. The amount of heat compensation will be different between single installation and two−piece installation.

Range: 1P or 2P

1P — The installation is single piece.

2P — The installation is two separate pieces. Default is 2P.

Option 41 — Variable Speed Blower

This selection allows the installer to select between a single speed or variable motor.

Off − The system has a single speed (PSC) blower. On − The system has a variable speed blower. Factory default is OF (Off)

Option 44 — Super Comfort Heat

This option is only available on heat pump units HP (HP, H2) when Option 41 (Variable Speed Blower) is set to On and the system has a valid OAT sensor.

OF (Off) − Comfort Heat is off On − Comfort Heat feature is on.

If the outdoor air temperature is between 12 to 40_F (−11 to 4_C) and the compressor is running in heating, then the fan output is turned off. This will signal the variable speed blower to reduce the air speed. The fan output is turned

36

Image 38
Contents Installation Instructions Programmable Control Non−Programmable ControlPage Table of Contents Safety ConsiderationsIntroduction Installation Considerations PowerOutdoor Temperature Sensor ModelsRemote Indoor Temperature Sensor Two−Piece Thermostat ConfigurationInstallation Wiring− TP−NAC / TP−NHP Carton Contents AC/HP Control LocationInstall AC/HP Control Electrical Operation HazardUnit Damage Hazard Two−Piece Installation − Press Tabs to Remove Backplate− Take Apart − Backplate Mounting Relays − Secure Wires to Terminal Strip − Attach Display to Backplate − Equipment Control Module on Equipment − Standoff − Cover on Equipment Control Module Single−Piece Installation − Equipment Control Module Set AC/HP Control Configuration − Reattach Display ModulePage To Enter Configuration Mode Configuration Options -Selection Option 01 Equipment TypeOption 04 Fan G On With W/W1 Option 02 Clean Filter TimerOption 03 Fahrenheit/Centigrade − Remote Room Sensor − Parallel Wiring Option 06 Cooling Lockout Below 55F/13COption 10 Reversing Valve Option 08 Auxiliary Heat Lockout TemperatureOption 07 Zoning Option 13 Room Air Temperature Offset Adjust Option 11 Deadband Setting Between Heat & CoolOption 12 Smart Recovery Option 15 Enable Auto ModeOption 17 Time Between Equipment Stages Option 18 Backlight ConfigurationOption 16 Maximum Cycles Per Hour Option 20 Outdoor Air Temperature Offset Adjustment Option 21 Keypad Lockout programmable models onlyOption 21 Keypad Lockout non−programmable models only Page Option 26 Minimum Cooling Setpoint Option 24 Programmable/Non−ProgrammableOption 25 Number of Programmable Periods Option 30 Programmable Fan programmable models only Option 27 Maximum Heating SetpointOption 28 UV Light Reminder Page Option 44 Super Comfort Heat Option 33 Single or Two−Piece InstallationOption 41 Variable Speed Blower Option 99 Reset to Factory Defaults System START−UP and Checkout Final Settings Energy Star Default ScheduleVacation programmable models only Timers Operational InformationTen−Minute Staging Timer DefrostEmergency Heat Mode Equipment On IndicatorsHeat/Cool Setpoints Desired Temperature Three−Minute Minimum on TimeRelays Programmable Fan programmable models onlyDry Contact Temperature Offset After Power Cycle TroubleshootingError Codes Page Equipment Configuration Outputs − Equipment Configuration Outputs Wiring Diagrams − Display to Equipment Control Module ConnectionWiring DIAGRAMScont − Fan Coil shown with Auxiliary Connection #1 − Fan Coil with Air Conditioner Indicates connection may not be required/available − Furnace with Air Conditioner − Thermostat with Dry Contact Control for Run Time Outdoor Sensor Remote Room Air Conditioner − Single−stage Furnace with Air Conditioner and Split Power Thermostat Configuration Record Mode SettingsConfiguration Options Configuration Options Page Catalog No TP-PAC-3SI

TP-PHP, TP-NHP, TP-NAC, TP-PAC specifications

Carrier TP-PAC, TP-NAC, TP-NHP, and TP-PHP are part of Carrier's advanced product lineup designed for efficient, reliable, and high-performance heating and cooling systems. These products cater to various applications, from commercial to industrial, ensuring optimal climate control while maximizing energy efficiency.

The TP-PAC (Packaged Air Conditioner) is engineered for easy installation and maintenance, providing robust performance in diverse settings. This unit features high-efficiency compressors and advanced refrigerant management technology, which reduces energy consumption while maintaining superior cooling capabilities. Its modular design allows for easy scalability, enabling businesses to adjust their cooling capacity as required. Moreover, the TP-PAC is equipped with an intelligent control system that monitors performance metrics in real-time, facilitating proactive maintenance and reducing downtime.

The TP-NAC (Air-Cooled Chiller) incorporates cutting-edge technology to enhance its operational efficiency. This chiller utilizes advanced variable-speed compressor technology, which adapts to varying load conditions, significantly reducing energy costs. Its environmentally friendly refrigerant options comply with the latest regulations, further enhancing its sustainability profile. The TP-NAC is perfect for applications that demand precise temperature control, making it ideal for data centers and manufacturing facilities.

The TP-NHP (Heat Pump) is designed for year-round climate control, capable of both heating and cooling. This versatile unit employs a new-generation hot gas reheat system, allowing it to maintain comfortable indoor temperatures even during extreme weather conditions. Additionally, the TP-NHP features advanced zoning capabilities, permitting customized temperature settings for different areas of a building. This flexibility not only enhances comfort but also optimizes energy expenditure.

The TP-PHP (Packaged Heat Pump) combines the efficiency of the TP-NHP with a compact design perfect for urban installations where space is limited. It boasts quiet operation, making it suitable for residential areas and noise-sensitive environments. The unit's smart technology features enable users to monitor and control their systems remotely, providing convenience and peace of mind.

In summary, Carrier's TP-PAC, TP-NAC, TP-NHP, and TP-PHP represent the forefront of heating and cooling technology. With their emphasis on efficiency, reliability, and cutting-edge features, these units are well-equipped to meet the demands of modern climate control in diverse applications. By prioritizing energy efficiency and sustainable practices, Carrier continues to lead the way in the HVAC industry, ensuring comfortable and environmentally friendly solutions for all users.