PLANNING YOUR INSTALLATION
Clearances to combustibles are determined from testing to applicable standards for allowable heat transfer. The clearances allowed as shown here, do not take into account operation or serviceability requirements.
CLEARANCES |
|
|
| Rear Wall or Alcove |
Standard residential or manufactured (mobile) home instal- |
| |||
lation. These appliances require the following minimum |
| |||
clearances to combustibles: |
|
|
| |
MINIMUM CLEARANCES TO COMBUSTIBLES |
| |||
|
|
|
|
|
Model: T300P | Manufactured (Mobile) Home |
| ||
Series | or Residential Installation |
|
| |
Clearance to | Horizontal Flue – | Interior Vertical |
|
|
Directly Through | Flue |
|
| |
Combustibles | Wall |
|
|
|
| inch / millimeter | inch / millimeter |
|
|
A - Sidewall to unit | ♦6” / 153 mm | ♦6” / 153 mm |
|
|
B - Backwall to | 2” / 51 mm | 9” / 229 mm |
|
|
unit |
|
|
|
|
C - Sidewall to unit | 2” / 51 mm | 2” / 51 mm |
|
|
Corner |
|
|
|
|
D - Max. Depth of | •18” / 458 mm | •18” / 458 mm |
|
|
Alcove |
|
|
|
|
E - Flue to Wall | 3” / 77 mm | 3” / 77 mm |
|
|
♦ Measured to outside projection of cast stove top |
|
| ||
• Minimum Alcove Measurements: Height 48” / 1220 mm |
| Corner | ||
| Width 41” / 1042 mm |
|
| |
Minimum clearances specified may not allow for ease |
| |||
of operation and maintenance (please take this into |
| |||
account when planning the installation). If installed to |
| |||
the minimum clearances, removal of the appliance may |
| |||
be necessary for servicing. |
|
|
|
Page 6