Lennox Hearth operation manual SPECIFICATIONS - Model T300P Series

Models: T300P

1 40
Download 40 pages 55.48 Kb
Page 26
Image 26
SPECIFICATIONS - Model T300P Series

SPECIFICATIONS - Model T300P Series

Flue Size

 

3” / 76mm Rear

Width, Overall

 

28 3/4” / 730 mm

Depth, Overall

 

26 1/2” / 660 mm

Height

 

28 3/4” / 730 mm

Floor to Rear

 

 

Flue Center

 

8 3/4” / 222 mm

Facing Back of Unit,

 

 

Outside Edge of Left Leg

 

 

To Center of Rear

 

 

Flue Outlet

 

10 1/2” / 267 mm

Floor to Rear

 

 

Outside Air Inlet

 

10” / 254 mm

Facing Back of Unit

 

 

Outside Edge of Left Leg

 

 

To Center of Air Inlet

 

17 1/2” / 445 mm

Floor Protection

+

Front and Sides:6”/152mm

Requirements

 

Back: Up to 6” / 152mm

Standard Features

 

Fastfire Self Igniter

 

 

Wall Thermostat

 

 

(wire included)

Hopper Capacity

 

50 lbs.

Burn time

14-34 hours

Fuse, Control Board

 

5 amp, 25 volt, 3AG*

Fuse, Igniter

 

6 amp, 125 volt*

Heat Input (Max.)

13,000-32,000 BTU / hr

Overall Efficiency

 

85%

Emissions

0.43 gram / hr (varies w/

 

 

size and type of fuel)

 

 

EPA exempt

Ship Weight

 

363 lbs.

Room Air Blower

 

150 CFM; 1.5 amps,

 

 

2175 rpm

Auger Motor

 

1 RPM; .4 amps

Exhaust Blower

 

95 CFM: 1.0 amps,

 

 

2880 rpm

Note: Dimensions shown are approximations only (+/- ¼”)

BACK VIEW

28 3/4”

8 3/4”

 

10 “

10 1/2”

17 1/2”

SIDE VIEW

26 1/2”

28 3/4”

Face of door opening to stove back

23”

+Non-combustible thermal rated floor protection must be used when installed on carpet (see Floor Protec- tion, page 5). When installed at clearances less than 6”, the floor protector is only required to ex- tend to the wall.

Fuel delivery and burn times will vary depending on size and type of fuel used. Estimated heat in- put based on fuel value of 8400 BTU per lb.

* Fuses are rated as fast blow.

Page 26

Page 26
Image 26
Lennox Hearth operation manual SPECIFICATIONS - Model T300P Series