TROUBLESHOOTING (Qualified Technicians Only)

Unplug Appliance Before Performing Any Troubleshooting or Maintenance

PROBLEM

CAUSE(S)

SOLUTIONS

 

 

 

4. Blowers will

There is no power to the stove.

Check that the stove is plugged in to the wall outlet.

not operate

 

 

when the start

There is no power to the control

Check to see if your circuit breaker has tripped.

switch is de-

board.

 

pressed.

 

Check the wire connections on the high limit disc and

 

 

Control board.

 

 

 

5. There is soot

The window is being cleaned when

Turn down the room air blower or turn off stove before

or fly ash in the

the stove is operating.

cleaning to prevent dispersion of ash and soot into the

house.

There is leakage at the joints be-

room.

 

 

 

tween the exhaust blower, connec-

Seal up any leaks in the exhaust system with room tem-

 

tion or exhaust pipe connections.

perature vulcanizing silicone sealer (RTV).

 

This will be evidenced by dust on

 

 

the impeller of the room air blower,

DO NOT use a standard household vacuum or “shop vac”

 

and in the heat exchanger area.

as the filters will leak the fine particles of ash. Clean the

 

The vacuum cleaner is leaking.

stove with an approved ash vacuum ONLY.

 

 

 

 

 

6. Stove acts as if

Excessive sun light may be shining

Block excessive sunlight. Call your authorized Lennox

a fire is present

directly into firebox from window.

Hearth Products dealer if problem persists.

when there is

 

 

not a fire in the

 

 

grate.

 

 

 

 

 

7. Stove will not

The igniter element may have

Check igniter element fuse in rear stove compartment.

light.

failed.

Call your authorized Lennox Hearth Products dealer. See

 

 

alternate manual lighting procedure

 

There are not enough pellets in the

Prime the feed system (see page 18, Initial Start

 

UltraGrate.

Up/Empty Hopper or Feed Tube).

 

 

 

8. Fault

Photoeye not detecting flame.

Clean photoeye lens (see Clean Photoeye Lens on page

 

 

23.)

 

Stove has run out of fuel.

Check connection at control board following yellow wires

 

 

to all connectors.

 

 

Refill hopper.

 

A disk has tripped / pressure

Blower intake, exhaust passages and / or venting system

 

switch.

needs cleaning (follow routine and annual maintenance

 

 

procedures).

 

 

If this does not correct the problem contact your local au-

 

 

thorized Lennox Hearth Products dealer.

 

 

 