FLOOR PROTECTION

PLANNING YOUR INSTALLATION

FLOOR PROTECTION

This appliance requires noncombustible floor protection. If the floor protection is to be stone, tile, brick, etc., it must be mor- tared or grouted to form a continuous non-combustible surface. If a chimney connector extends horizontally over the floor, the protection must cover the floor under the connector and at least 2" to either side.

A noncombustible floor protector must fully cover the area beneath the appliance and extend 6” to the front, 6” to the sides, and up to 6" from the back as illustrated below.

*Note: When installed at clearances less than 6”, floor protection is only required to extend to the wall.

T300P SERIES

*Up to 6"/153mm minimum