TROUBLESHOOTING (Qualified Technicians Only)

Unplug Appliance Before Performing Any Troubleshooting or Maintenance

PROBLEM

CAUSE(S)

SOLUTIONS

 

 

 

1. Fire burns with

There is insufficient combustion air.

Remove any clinkers or ash from the bottom of the grate that

a lazy orange

 

might be obstructing the primary air holes.

flame. Pellets

 

Change to a better grade of fuel if necessary.

build up in the

 

grate and the

 

Check that the damper has been opened enough for the

window gets

 

sooted up.

 

amount of fuel feed.

 

 

Check that the heat exchange tubes are not coated with ash.

 

 

Clean internal exhaust ducts.

 

 

Check gasket seal around the door. Use a thin strip of paper,

 

 

1 in. wide. Open the door and close it on the paper strip. A

 

 

slight friction should be felt when the paper strip is pulled.

 

 

Repeat this process at various locations around the door

 

 

gasket. Replace the door gasket if necessary.

 

 

Check for blockage in the air inlet tube or exhaust pipe.

 

 

Clean as necessary.

 

 

Close ash slide plates.

 

 

Have your authorized Lennox Hearth Products dealer check

 

 

your Exhaust Blower.

 

 

 

2. Fire goes out

The hopper is empty

Refill hopper.

or stove shuts

Pellets are not feeding.

See Pellets will not feed (#3) below.

down automati-

cally

The high limit temperature switch

Allow stove to cool for 1 hour and re-light. If the stove has

 

 

has tripped.

been operating at a medium to high burn rate and the room

 

There is too much combustion air

air blower has been turned down low then the fan should be

 

turned up higher. If this problem persists (particularly at

 

for the amount of fuel.

lower burn rates) then the high limit disc should be replaced

 

 

by your authorized Lennox Hearth Products dealer.

 

 

Adjust the damper to reduce combustion airflow.

 

 

 

3. Pellets will not

Stove has run out of fuel.

Refill hopper.

feed.

The auger motor or circuit board

Check to be sure that there is no blockage in the pressure

 

 

may be defective. The pressure

tap or hose. Have your authorized Lennox Hearth Products

 

switch tap or hose may be blocked.

dealer diagnose the problem and clean or replace any nec-

 

 

essary parts.

 

Back pressure in venting tripping

If new installation check for excessive 90˚ bends, long hori-

 

pressure switch.

zontal runs or excessive vertical run of 3” pipe. Possibly

 

 

change to 4” pipe. If older installation check for excessive

 

 

ash accumulation in pipe or other obstructions. Clean out

 

 

pipe.

 

Thermostat is in stand-by mode.

Check to see if thermostat is set to low or if sun is shining

 

 

directly on thermostat.

 

Thermostat wires disconnect.

Re-install wires.

 

High limit switch may have been

Allow stove to cool. Increase room air blower setting.

 

tripped.

 

 

Self-aligning bearing in auger motor

Gently tap the auger motor.

 

may be mis-aligned.

 

 

 