SUNLINE 2000™ SPLIT-SYSTEM

J￿

SUNLINE 2000SPLIT-SYSTEM

 

 

CONDENSING UNITS

 

(AIR COOLED)

 

INSTALLATION MANUAL

Supersedes: 035-15407-002-A-0304

035-15407-002-B-0404

MODELS H5CE090, H3CE120 & H1CE150

8.9 - 9.5 EER

GENERAL

These condensing units are designed for outdoor installation on a roof or at ground level. Every unit is completely piped and wired at the factory and is shipped ready for immediate installa- tion. Only the liquid and suction lines to the evaporator coil, the control wiring and the main power wiring are required to com- plete the installation. Each unit is dehydrated, evacuated, leak tested and pressure tested at 450 psig before being pressur- ized with a holding charge of refrigerant-22 for shipment and/or storage.

All controls are located in the front of the unit and are readily ac- cessible for maintenance, adjustment and service. All wiring (power and control) can be made through the front of the unit.

Refer to Table 7 for condenser cooling capacities and power re- quirements.

All forms may be ordered from:

Standard Register

Toll Free Telephone: 877-318-9675

Toll Free Fax: 877-379-7920

INSPECTION

As soon as a unit is received, it should be inspected for possible damage during transit. If damage is evident, the extent of the damage should be noted on the carrier's freight bill. A separate request for inspection by the carrier's agent should be made in writing. See Form 50.15-NM for more information.

REFERENCE

This instruction covers the installation and operation of the ba- sic condensing unit. For information on the installation and op- eration of the evaporator blower units, please refer to the matching air handler installation manual.

Additional information on the design, installation, op- eration and service of this equipment is available in the following reference form.

550.23-N1.1V- Low Ambient Accessory

Replacement Parts:

Refer to Parts Manual for complete listing of replacement parts on this equipment.

CAUTION

THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH THE ENCLOSED INSTALLATION INSTRUCTIONS AND ANY APPLICABLE LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED TO, BUILDING, ELECTRICAL, AND MECHANICAL CODES.

WARNING

INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE OPERATION OF THE PRODUCT COULD CAUSE PERSONAL INJURY OR PROPERTY DAMAGE.

Installer should pay particular attention to the words: NOTE, CAUTION and WARNING. Notes are intended to clarify or make the installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that personal injury and/or equipment damage may result if installation procedure is not handled properly.