14.13.5 SNTP
Time synchronization is an essential element for any business that relies on an IT system. The reason for this is that these systems all have clocks that are the source of time for files or operations they handle. Without time synchronization, time on these systems can vary and this can cause virtual server schedule processes to fail and system log exposures with wrong data.
There are two methods to synchronize time: synchronize with a PC or SNTPv4. If you choose synchronize with PC, the router will synchronize with a PC. If you choose SNTPv4, the router will use the protocol to synchronize with the time server. Synchronization with time server, SNTP v4, needs to configure service, time_server and time_zone. Synchronization with PC does not require the above parameters.
Move the cursor “ >> “ to sntp and press enter.
>> method | Select time synchronization method |
service | Tigger SNTP v4.0 service |
time_server1 | Configure time server 1 |
time_server2 | Configure time server 2 |
time_server3 | Configure time server 3 |
updaterate | Configure update period |
time_zone | Configure GMT time zone offset |
list | Show SNTP configuration |
To configure SNTP v4 time synchronization, follow the procedures detailed below:
Move the cursor to method and press enter.
Command: admin sntp method <SNTPv4SyncWithPC>
Message: Please input the following information.
SYNC method (Enter for default) <SyncWithPC> : SNTPv4
Move the cursor to service and press enter.
Command: admin sntp service <DisableEnable>
Message: Please input the following information.
Active SNTP v4.0 service (Tab Select) <Enable> : Enable
Move the cursor to time_server1 and press enter.
Command: admin sntp time_server1 <string>
Message: Please input the following information.
Time server address(Enter for default)
You can configure up to three time servers in this system.
Move the cursor to update_rate and press enter.
Command: admin sntp update_rate <10~268435455>
Message: Please input the following information.
Update period (secs) (Enter for default) : 86400
NB712 / | NB714 User Guide | 93 |
YML829 | Rev1 |
|