Bryant SYSTXBBUIZ01 instruction manual Table of Contents, Safety Considerations, Introduction

Page 1

Installation and Start-Up Instructions Evolution™ Zone Control

SYSTXBBUIZ01

ZONE

 

HEAT

HOLD

COOL

 

OFF

EVOLUTIONSYSTEM

Evolution™ Zone Control

SYSTXBBUIZ01

A04031

NOTE: Read the entire instruction manual before starting the installation.

This symbol indicates a change since the last issue.

TABLE OF CONTENTS

 

SAFETY CONSIDERATIONS

1

INTRODUCTION

1

INSTALLATION AND START-UP OVERVIEW

1

INSTALLATION

1

INITIAL POWER-UP

5

QUICK START

7

INSTALL / SERVICE MENUS

7

OPERATIONAL INFORMATION

12

TROUBLESHOOTING

13

SAFETY CONSIDERATIONS

Read and follow manufacturer instructions carefully. Follow all local electrical codes during installation. All wiring must conform to local and national electrical codes. Improper wiring or installa- tion may damage the Evolution™ Zone System. Recognize safety information. This is the safety-alert symbol . When you see this symbol on the equipment and in the instruction manual, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards, which will result in severe personal injury or death.

—1—

Cancels: New

II UIZ01-0-1

 

03-04

WARNING signifies a hazard, which could result in personal injury or death. CAUTION is used to identify unsafe practices, which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which may result in enhanced installation, reliability, or operation.

INTRODUCTION

The Evolution Zone System consists of several intelligent com- municating components which includes the Evolution Zone Con- trol (or User Interface), Smart Sensors, Damper Control Module, variable- speed furnace or FE fan coil, 2-speed AC or HP, which continually communicate with each other via a four-wire connec- tion called the ABCD bus. Commands, operating conditions, and other data are passed continually between components over the ABCD bus. The result is a new level of comfort, versatility, and simplicity.

All furnaces or fan coils are variable-speed and multi stage for maximum flexibility, efficiency, and comfort. They support con- trolled ventilation, humidification, dehumidification, and air qual- ity control. Either a dual capacity (communicating), or a standard 24 vac controlled outdoor unit may be used.

When using conventional outdoor units, the variable-speed furnace or fan coil provides the 24 volt signals needed to control them. Also, the Evolution™ Damper Control Module (P/N SYSTXBB4ZC01) allows connection of a conventional HRV or ERV without the need for a separate wall control.

All system components are controlled through the wall mounted Evolution™ Zone Control, which replaces the conventional ther- mostat and provides the homeowner with a single wall control for all features of the system.

INSTALLATION AND START-UP OVERVIEW

This instruction covers installation of the Evolution™ Zone Control only. Physical installation instructions for the indoor and outdoor equipment, Damper Control Module, and accessories are provided with each unit.

Setup, commissioning, operation, and troubleshooting of the Evolution Zone System is covered only in this installation instruc- tion. It is the guide to connecting the system components and commissioning the system once all physical components are installed. Special screen prompts and start-up capabilities are provided in the Evolution System to simplify and automate the initial commissioning of the system.

Install Evolution™ Zone Control according to this instruction.

Install indoor unit, outdoor unit, and accessories according to their instructions.

Wire complete system according to this instruction.

Setup, commission, and operate system according to this instruction to assure a smooth and trouble free start-up.

INSTALLATION

A. Step 1 — Check Equipment and Job Site

INSPECT EQUIPMENT — File claim with shipping company, prior to installation, if shipment is damaged or incomplete.

Image 1
Contents Safety Considerations Table of ContentsInstallation and START-UP Overview InstallationEvolution Zone Control Location and Wiring Considerations Thin Decorative Backplate Large Decorative Backplate Equipment Wiring DiagramsPower Up Sequence Initial POWER-UPSelecting Outdoor Unit Selecting Electric Heater Selecting AccessoriesEquipment Summary Filter SelectionQuick Start Install / Service MenusSetup Menu Install MenuEquipment Summary Menu Setup = Heat Pump / AC Setup = FAN CoilSetup = Zoning Setup = AccessoriesCheckout Menus Service = Furnace Status Service MenusService = FAN Coil Status Service = Heat Pump / AC StatusOperational Information Troubleshooting Page