Bryant SYSTXBBUIZ01 instruction manual Quick Start, Install / Service Menus

Page 7

QUICK START

For first time installers, Quick Start will allow a quick start up of the Evolution Zone System before learning all the details of system operation. However, for the best possible comfort and operation refer to the Evolution Zone Control™ Owner’s Manual.

A.Set Day, Time & Desired Humidity

1.Flip down the door at the base of the Evolution Zone Control™ and press the BASIC button.

2.Adjust the highlighted HOUR setting using the TIME (+/−) button.

3.Press SCROLL button (down) to highlight MINUTE.

4.Adjust the MINUTE setting using the TIME (+/−) button.

5.Press SCROLL button (down) to highlight DAY.

6.Adjust the current DAY setting using the TIME (+/−) button.

7.Press SCROLL button (down) to highlight HUMIDITY.

8.Press the red HEAT button to select heating humidity.

9.Adjust desired heating humidity level using either (+/−) button.

10.Press the blue COOL button to select cooling humidity.

11.Adjust the desired cooling humidity level using either(+/−)button.

12.To exit press BASIC button or close door.

13.If changes are made, you will be asked to SAVE CHANGES? YES/NO.

B.Override Heating Schedule

1.Press the red HEAT button. Heating mode is confirmed when the red LED next to the red HEAT button is lit.

2.Use the TEMP (+/−) button to select your desired heating temperature.

3.The default time for temporarily overriding the temperature schedule is 2:00 HRS as indicated by the text on the lower left.

NOTE: Override time will not appear if programming has been turned off.

4.You can change the temporary override time in 15-minute increments by pressing the TIME (+/−) button until the desired override time is selected, or press the HOLD button anytime to override the schedule indefinitely.

C.Override Cooling Schedule

1.Press the blue COOL button. Cooling mode is confirmed when the blue LED next to the COOL button is lit.

2.Use the TEMP (+/−) button to select your desired cooling temperature.

3.The default time for temporarily overriding the temperature schedule is 2:00 HRS as indicated by the text on the lower left.

NOTE: Override time will not appear if programming has been turned off.

4.You can change the temporary override time in 15-minute increments by pressing the TIME (+/−) button until the desired override time is selected, or press the HOLD button anytime to override the schedule indefinitely.

D. Quick Program Schedule for All Days

This section will give you a quick program schedule for ALL- DAYS of the week. For more information on how to create customized schedules for every day, the entire week, or weekend, refer to the Owner’s Manual.

1.Flip down the door at the bottom of the control.

2.Press the SCHEDULE button, which allows you to create one schedule for the entire home.

3.Press either the LEFT or RIGHT side button repeatedly (if necessary) until ALLDAYSis displayed. The WAKE time period will be highlighted.

4.Using the TIME (+/−) button, set the start time for this time period.

5.Press the red HEAT button. Heating temperature will begin flashing.

6.Set the heating temperature using the TEMP (+/−) button.

7.Press the blue COOL button. Cooling temperature will begin flashing.

8.Set the cooling temperature using the TEMP (+/−) button.

9.Set the remaining periods by using the SCROLL button to select DAY,″ ″EVENING,and SLEEP.

10.To copy a zone, use SCROLL button to select COPY. Select YES and copy this zone schedule to other zones using NO or YES

11.Exit the scheduling mode by either closing the door or pressing the SCHEDULE button.

12.If changes are made, you will be asked to SAVE CHANGES YES/NO

INSTALL / SERVICE MENUS

INSTALL/SERVICE

EQUIPMENT SUMMARY

INSTALL

SETUP

CHECKOUT

SERVICE

SOFTWARE VERSION 1

EXIT SELECT

A03200

Fig. 20 — INSTALL / SERVICE MENUS

The INSTALL / SERVICEmenus contain a set of vital information. This information enables the Installer or Service person to view a summary of what has been installed, etc. This information is notcovered in the Owner’s Manual.

To enter INSTALL / SERVICE menus, press and hold the ADVANCED button for at least ten seconds. The following menu will appear (See Fig. 20):

NOTE: The INSTALL / SERVICE menu will automatically exit after 60 minutes of no push button activity.

EQUIPMENT SUMMARY: Shows all equipment recognized by and attached to the system.

INSTALL: Used when adding, changing out, or uninstalling equipment.

SETUP: Used to view or modify equipment settings.

CHECKOUT: Allows testing of equipment operation

SERVICE: Used to view operation and fault history of equipment and enter dealer name/phone number for display.

—7—

Image 7
Contents Installation Table of ContentsSafety Considerations Installation and START-UP OverviewEvolution Zone Control Location and Wiring Considerations Thin Decorative Backplate Large Decorative Backplate Equipment Wiring DiagramsPower Up Sequence Initial POWER-UPSelecting Outdoor Unit Filter Selection Selecting AccessoriesSelecting Electric Heater Equipment SummaryQuick Start Install / Service MenusSetup Menu Install MenuEquipment Summary Menu Setup = Accessories Setup = FAN CoilSetup = Heat Pump / AC Setup = ZoningCheckout Menus Service = Heat Pump / AC Status Service MenusService = Furnace Status Service = FAN Coil StatusOperational Information Troubleshooting Page

SYSTXBBUIZ01 specifications

The Bryant SYSTXBBUIZ01 is a versatile and innovative thermostat designed to optimize the performance and efficiency of heating, ventilation, and air conditioning (HVAC) systems. As part of Bryant's commitment to providing reliable climate control solutions, this unit integrates advanced technologies for seamless user experience and enhanced energy savings.

One of the most notable features of the SYSTXBBUIZ01 is its intuitive interface, which includes a large, user-friendly touchscreen display. This feature makes it easy for homeowners to monitor and adjust their indoor climate with just a few taps. The thermostat supports both heating and cooling modes, allowing users to create customized schedules that fit their lifestyle and maximize comfort throughout the year.

The SYSTXBBUIZ01 utilizes smart technology to provide homeowners with remote access through a mobile application. This capability allows users to adjust their home’s temperature settings from anywhere, ensuring that they can maintain optimal comfort even when away from home. The application also provides energy usage reports, empowering users to make informed decisions about their energy consumption.

In terms of connectivity, the SYSTXBBUIZ01 is equipped with Wi-Fi capability, enabling easy integration with existing smart home systems. This feature allows for voice command controls via compatible virtual assistants, adding an extra layer of convenience to everyday operations.

The thermostat is designed to be compatible with a variety of HVAC systems, including single-stage and multi-stage systems, ensuring broad applicability in many homes. Additionally, the device includes advanced sensors that monitor temperature and humidity levels to provide precise climate control, further enhancing energy efficiency and comfort.

Energy-saving features are a significant highlight of the SYSTXBBUIZ01. The thermostat is equipped with adaptive recovery technology, which learns the heating and cooling patterns of the home, allowing it to optimize operation schedules for maximum efficiency. Additionally, it includes features like geofencing, which adjusts the temperature based on the homeowner’s location, further promoting energy conservation.

The Bryant SYSTXBBUIZ01 stands out as a resilient and effective solution for modern home climate control, combining user-friendly design, smart functionalities, and energy-saving technologies. Its advanced features make it an ideal choice for anyone looking to enhance their home’s comfort and efficiency.