Emerson Process Management 1F95-1291 specifications Save these instructions for future use, Index

Page 1

Big Blue Humidity Universal Thermostat

with Humidity/Dehumidity Control and

Automatic Heat/Cool Changeover Option

 

Single Stage, Multi-Stage, Heat Pump

Save these instructions for future use!

Installation and Operating Instructions

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATINGTHIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Model

 

Programming Choices

 

 

 

1F95-1291

7 Day

5+1+1 Day

Non-Programmable

 

 

 

 

 

 

 

 

 

 

APPLICATIONS

 

 

 

 

 

 

 

THERMOSTAT APPLICATION GUIDE

 

1F95-1291 Humidity Control Touchscreen Thermostat

 

 

 

 

 

 

 

Thermostat

Thermostat

 

Maximum

 

 

 

Stages

 

 

 

Configuration Options

Applications

 

 

 

 

Heat/Cool

 

 

 

 

 

 

 

 

Single Stage 1

Gas, Oil, Electric, Heat Only,

 

1+1

 

 

 

No Heat Pump (SS1)

Cool Only or Heat/Cool

 

 

 

 

 

 

 

 

 

 

Systems, 2 or 3 wire Hydronic

 

 

 

 

 

 

 

 

 

 

 

Multi Stage 2

Zone (Hot Water or Steam)

 

2+2

 

 

 

No Heat Pump (MS2)

Systems, 24 Volt or Millivolt

 

 

 

 

 

 

 

 

 

Heat Pump 1

Single Stage Compressor

 

 

 

 

 

Single Stage Compressor

Heat Pump Systems - up to 2

 

3+1

 

 

 

Heat Pump (HP1)

Stages Aux./Emergency Heat

 

 

 

 

 

 

 

 

 

 

 

 

Heat Pump 2

Two Stage or Two Compressor

 

 

 

 

 

Two Stage or Two

 

 

 

 

 

Heat Pump systems - up to 2

 

4+2

 

 

 

Compressor Heat Pump

 

 

 

 

Stages Aux./Emergency Heat

 

 

 

 

 

(HP2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

Electrical Rating:

 

 

 

 

 

Battery Power

mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire

20 to 30 VAC

 

 

Terminal Load

1.5A per terminal, 2.5A maximum all terminals combined

Setpoint Range

45 to 99°F (7 to 37°C)

Rated Differentials:

Fast.

Slow

Heat (Single Stage/Multi-Stage)

0.6°F

1.5°F

Cool (Single Stage/Multi-Stage)

1.2°F

1.7°F

Heat Pump

1.2°F

1.7°F

Emer Heat

0.6°F

1.7°F

Operating Ambient

32°F to +105°F (0 to +41°C)

Operating Humidity

90% non-condensing max.

Shipping Temperature Range

-40 to +150°F (-40 to +65°C)

Dimensions Thermostat

4-9/16"H x 5-13/16"W x 1-3/16"D

Humidity Setpoint Range

5 to 50%

 

 

Dehumidification Setpoint Range

40 to 95%

 

 

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Index

Page

Installation

2

Wiring Diagrams

3

Thermostat Quick Reference

5

Installer Configuration Menu

6

Operating Your Thermostat

10

Programming

12

Troubleshooting

15

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this prod- uct may replace a product that contains mercury.

Mercury and products containing mercury must not be discarded in household trash. Do not touch any spilled mercury. Wearing non-absorbent gloves, clean up any spilled mercury and place in a sealed container. For proper disposal of a product containing mercury or a sealed container of spilled mercury, place it in a suitable shipping container. Refer to www.thermostat-recycle.orgfor loca- tion to send the product containing mercury.

 

PART NO. 37-7313B

www.white-rodgers.com

Replaces 37-7313A

www.emersonclimate.com

1241

Image 1
Contents Single Stage, Multi-Stage, Heat Pump Save these instructions for future useModel Programming Choices 1F95-1291 1F95-1291 Humidity Control Touchscreen ThermostatInstalling New Thermostat InstallationBattery Location Power Stealing SwitchesSingle Stage and Multi-Stage Connections Wiring DiagramsHeat Pump Connections 24 VAC 24 VAC 120 VACDisplays and Keypad Lockout when in keypad lockout mode Programming and Configuration ItemsThermostat Quick Reference Home Screen DescriptionKey INSTALLER/CONFIGURATION MenuHeat Cool Heat Pump Emer Heat Mode Med SlowINSTALLER/CONFIGURATION Menu Select Remote Sensor as Indoor or Outdoor If Record the number you select for future useCheck Thermostat Operation Operating Your ThermostatFan Operation Heating/HumidifierChoose the Fan Setting Auto or On Emergency ModeChoose the System Setting Cool, Off, Heat, Em, Auto Manual Operation for Non-Programmable ModeProgramming Energy Saving Factory Pre-Program Programmable Fan OptionPlanning Your Program Important Worksheet for Re-Programming 5+1+1 and 7 Day Program Wired Remote Temperature SensingHeating Wake Up Leave For Work Return Home Go To Bed Morning Fan Day Evening NightAveraging or Weighting Remote Sensors TroubleshootingDual Fuel Temperature Setpoint Blower Balance Point for HeatingCommon problems Reset Operation Symptom Possible Cause Corrective Action

1F95-1291 specifications

Emerson Process Management has established itself as a leader in providing innovative automation solutions to various industries. One of its notable offerings is the 1F95-1291, a highly advanced and reliable component specially designed for process control systems. This device is essential for optimizing operational efficiency and enhancing the performance of various industrial applications.

One of the main features of the 1F95-1291 is its robust design, which ensures reliability even in harsh industrial environments. The device is carefully constructed to withstand high levels of vibration, temperature fluctuations, and other challenging conditions. This durability reduces downtime and maintenance costs, allowing operators to focus on productivity.

Technologically, the 1F95-1291 integrates seamlessly with Emerson's extensive suite of control systems, providing compatibility and ease of integration. Its advanced communication capabilities allow it to interface with various field devices, enhancing the overall functionality of the automation system. The device supports various industrial communication protocols, ensuring versatile connectivity options that meet the diverse needs of modern industries.

The 1F95-1291 also features sophisticated algorithms that enable real-time data processing and analysis. This capability empowers operators to make informed decisions based on accurate and timely information. The built-in diagnostics function continuously monitors the system's health, providing alerts and insights that help in preemptive maintenance planning.

A standout characteristic of the 1F95-1291 is its user-friendly interface, designed to simplify operation and reduce training time. The intuitive display allows users to access critical information quickly, facilitating efficient management of operations. Additionally, firmware updates are easily manageable, ensuring that users can take advantage of the latest advancements without significant downtime.

In summary, Emerson Process Management's 1F95-1291 is a cutting-edge solution that exemplifies the company's commitment to innovation, reliability, and user-centric design. With its robust construction, advanced technologies, and user-friendly features, the 1F95-1291 is an essential asset for any organization seeking to enhance its process control capabilities and drive operational excellence. The device's adaptability to various industrial environments further underscores its value, making it a preferred choice among professionals in the field.