Emerson Process Management 1F95-1291 Thermostat Quick Reference, Home Screen Description

Page 5
Set Temperature/Humidity
Temperature UP/Down used for modifying setpoint as well as to navigating the menus
Press to view
Humidity setpoint
Menu key for entering different modes such as Cleaning, Configuration, Set
Battery Level Indicator Time and Set Schedule Indicating the current power level
of the 2 “AA” batteries. Full power remaining. Half power remaining.
Change The batteries should be replaced at this time.
Figure 9 – Programming & Configuration Items

THERMOSTAT QUICK REFERENCE

Home Screen Description

Figure 8 – Home Screen Display

Note: If is displayed, the thermostat is battery powered. When battery power remaining

is approximately half,

will

be displayed. If the home is

 

going to be unoccupied for an extended period (over 3 months)

and is displayed, the batteries should be replaced before leaving.

Time of Day

System

Switch

Fan

Switch

 

Room

Day of Week

Temperature

Indicates when thermostat is calling for Heat or Cool

Programming and Configuration Items

1Displays and "Keypad Lockout" when in keypad lockout mode.

Displays and "Temperature Limit" and "Keypad Lockout" when limited range is activated and locked. Displays only "Temperature Limit" when limited range is activated.

2Indicates period of day being programmed.

3RUN SCHEDULE (run program) key.

4SET TIME key or HOLD temperature key.

5Displays "Change Filter"/"Change Pad"/"Change UV Lamp" when the system has run for the programmed filter/humidity pad/UV lamp time period as a reminder to change or clean your filter/humidity pad or to replace UV lamp.

6COPY key or INSTALLER CONFIG key.

7CLEAN DISPLAY key allows 30 seconds to wipe off the display or ADVANCE DAY key for programming.

8Used in programming to set time and in configuration menu to change selections.

9"Hold Until" indicates the time when a temporary hold period will end.

10"Hours" and "Days" displays during steps in installer configuration.

11The words "Hold At" are displayed when the thermostat is in the HOLD mode. "Temporary Hold At" is displayed when the thermostat is in a temporary HOLD mode.

12"Humidity" indicates that the "Set At" display is Hu- midity setpoint.

13"System On" indicates when heating or cooling stage is energized. "+2" indicates when a second stage is energized.

14"Copy" indicates the copy program feature is being used during programming.

16

 

 

 

17

 

 

 

10

 

 

 

11

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

1

1

1

1

1

1

1

1

1

1

2

2

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

3

3

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

0

1

2

3

4

5

6

7

8

9

0

1

2

3

4

5

6

7

8

9

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

19

 

 

 

 

7

 

 

 

 

 

 

 

6

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

15A steady "Cool Savings" display indicates the feature is enabled in the installer menu. A flashing "Cool Savings" display indicates the feature is active.

16"Remote" indicates that the indoor remote temperature sensor, is being accessed. "Outdoor Remote" indi- cates the outdoor remote temperature sensor is being accessed.

17Display time, remote temperature or humidity.

18"Heat Pump" displays when the system configuration is set in HP1/HP2.

"Call for Service" indicates a fault in the heating/cooling

19systems. It does not indicate a fault in the thermostat.

20Auto Schedule key for Auto Schedule function or Humidity key to display current Humidity and Humidity setpoint.

21In Configuration Menu, shows screen number. If blank, thermostat is earlier model and requires instruction sheet

37-6914E.5

Image 5
Contents Single Stage, Multi-Stage, Heat Pump Save these instructions for future useModel Programming Choices 1F95-1291 1F95-1291 Humidity Control Touchscreen ThermostatInstalling New Thermostat InstallationBattery Location Power Stealing SwitchesHeat Pump Connections Wiring DiagramsSingle Stage and Multi-Stage Connections 24 VAC 24 VAC 120 VACDisplays and Keypad Lockout when in keypad lockout mode Programming and Configuration ItemsThermostat Quick Reference Home Screen DescriptionKey INSTALLER/CONFIGURATION MenuHeat Cool Heat Pump Emer Heat Mode Med SlowINSTALLER/CONFIGURATION Menu Select Remote Sensor as Indoor or Outdoor If Record the number you select for future useCheck Thermostat Operation Operating Your ThermostatFan Operation Heating/HumidifierChoose the Fan Setting Auto or On Emergency ModeChoose the System Setting Cool, Off, Heat, Em, Auto Manual Operation for Non-Programmable ModeProgramming Planning Your Program Important Programmable Fan OptionEnergy Saving Factory Pre-Program Worksheet for Re-Programming 5+1+1 and 7 Day Program Wired Remote Temperature SensingHeating Wake Up Leave For Work Return Home Go To Bed Morning Fan Day Evening NightAveraging or Weighting Remote Sensors TroubleshootingDual Fuel Temperature Setpoint Blower Balance Point for HeatingCommon problems Reset Operation Symptom Possible Cause Corrective Action

1F95-1291 specifications

Emerson Process Management has established itself as a leader in providing innovative automation solutions to various industries. One of its notable offerings is the 1F95-1291, a highly advanced and reliable component specially designed for process control systems. This device is essential for optimizing operational efficiency and enhancing the performance of various industrial applications.

One of the main features of the 1F95-1291 is its robust design, which ensures reliability even in harsh industrial environments. The device is carefully constructed to withstand high levels of vibration, temperature fluctuations, and other challenging conditions. This durability reduces downtime and maintenance costs, allowing operators to focus on productivity.

Technologically, the 1F95-1291 integrates seamlessly with Emerson's extensive suite of control systems, providing compatibility and ease of integration. Its advanced communication capabilities allow it to interface with various field devices, enhancing the overall functionality of the automation system. The device supports various industrial communication protocols, ensuring versatile connectivity options that meet the diverse needs of modern industries.

The 1F95-1291 also features sophisticated algorithms that enable real-time data processing and analysis. This capability empowers operators to make informed decisions based on accurate and timely information. The built-in diagnostics function continuously monitors the system's health, providing alerts and insights that help in preemptive maintenance planning.

A standout characteristic of the 1F95-1291 is its user-friendly interface, designed to simplify operation and reduce training time. The intuitive display allows users to access critical information quickly, facilitating efficient management of operations. Additionally, firmware updates are easily manageable, ensuring that users can take advantage of the latest advancements without significant downtime.

In summary, Emerson Process Management's 1F95-1291 is a cutting-edge solution that exemplifies the company's commitment to innovation, reliability, and user-centric design. With its robust construction, advanced technologies, and user-friendly features, the 1F95-1291 is an essential asset for any organization seeking to enhance its process control capabilities and drive operational excellence. The device's adaptability to various industrial environments further underscores its value, making it a preferred choice among professionals in the field.