Wiring Diagrams

The following is just a sample of the most common types of HVAC systems. Refer to your systems installation manual for wiring information.

CARRIER LOW VOLTAGE TERMINAL BOARD

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVERSION TO CARRIER

SPLIT SYSTEM CONDENSORS AND HEAT PUMP SYSTEMS

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT

R Y1 O B G E W2 L C Y2

24 VAC, RETURN

R

COMPRESSOR CONTACTOR

Y

REVERSING VALVE [COOLING MODE]

O

FAN CONTACTOR CIRCUIT

G

EMERGENCY HEATING CIRCUIT

E

2ND. STAGE HEATING CIRCUIT

W2

SYSTEM MONITOR LED

L

24 VAC, COMMON

C

W3

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS

COLEMAN LOW VOLTAGE TERMINAL BOARD

APRILAIRE MODEL 8336 HEAT PUMP CONVERSION TO COLEMAN HEAT PUMPS

3000 SERIES HEAT PUMP SYSTEMS

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT

R Y1 O B G E W2 L C Y2

24 VAC, RETURN

R

COMPRESSOR CONTACTOR

Y

REVERSING VALVE [HEATING MODE]

B

FAN CONTACTOR CIRCUIT

G

EMERGENCY HEATING CIRCUIT

E

2ND. STAGE HEATING CIRCUIT

W2

SYSTEM MONITOR LED

L

24 VAC, COMMON

X

O

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS

10

Image 10 Contents
Model Features Replacing Existing ThermostatInstalling the Model 8336 Thermostat Remove the cover using a coin or screwdriverMark placement of mounting holes. See . Set base aside Mounting HolesSwitch At the same time and hold for one second Changing Temperature DifferentialOperation Or buttonFew seconds Put the COOL-OFF-HEAT-EM switch into the Heat positionTo Test Thermostat Should turn offTroubleshooting LED IndicatorsChanging Fahrenheit F to Celsius C If problems with thermostat cannot be solved, call Wiring Diagrams Aprilaire Model 8336 Heat Pump ThermostatCYC Series Heat Pump Systems Heat Pump Systems Weathertron Lennox LOW Voltage Terminal Board Lennox LOW Voltage Terminal Board Limited Warranty