APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVERSION TO PAYNE
RELIANT AND ENDURA MODEL HEAT PUMP SYSTEMS
NOTE 1: W3 TERMINAL ON | APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT | |
PAYNE PCB CAPPED | ||
|
PAYNELOWVOLTAGETERMINALBOARD
R Y1 O B G E W2 L C Y2
24 VAC, RETURN
R
COMPRESSOR CONTACTOR
Y
REVERSING VALVE [COOLING MODE]
O
FAN CONTACTOR CIRCUIT
G
EMERGENCY HEATING CIRCUIT
E
2ND. STAGE HEATING CIRCUIT
W2
SYSTEM MONITOR LED
L
24 VAC, COMMON
C
3RD. STAGE HEATING CIRCUIT [CAPPED]
W3
THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS
APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVERSION TO RHEEM/RUUD
HEAT PUMP SYSTEMS
TERMVOLTAGE BOARDINAL
/RUUDLOWRHEEM
APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT
R Y1 O B G E W2 L C Y2
24 VAC, RETURN
R
COMPRESSOR CONTACTOR
Y
REVERSING VALVE [HEATING MODE]
B
FAN CONTACTOR CIRCUIT
G
EMERGENCY HEATING CIRCUIT
E
2ND. STAGE HEATING CIRCUIT
W2
SYSTEM MONITOR LED
L
24 VAC, COMMON
X
B
THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS
12