Aprilaire 8336 user manual CYC Series Heat Pump Systems

Page 11

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVERSION TO COMFORTMAKER

CYC SERIES HEAT PUMP SYSTEMS

NOTE 1: E AND W2 TERMINALS JUMPERED AT THERMOSTAT

NOTE 2: W2 TERMINAL ON COMFORTMAKER PCB CAPPED

NOTE 3: X TERMINAL ON COMFORTMAKER PCB CAPPED

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT

R Y1 O B G E W2 L C Y2

VOLTAGELOW BOARDTERMINAL

COMFORTMAKER

24 VAC, RETURN

R

COMPRESSOR CONTACTOR

Y

REVERSING VALVE [COOLING MODE]

O

FAN CONTACTOR CIRCUIT

G

2ND. STAGE HEATING CIRCUIT

W1

OUTDOOR THERMOSTAT [CAPPED]

W2

DEFROST SENSOR [CAPPED]

X

24 VAC, COMMON

C

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT CONVERSION TO HEIL-QUAKER

867.814 SERIES AND PH50 SERIES HEAT PUMP SYSTEMS

NOTE 1: E AND W2 TERMINALS

 

APRILAIRE MODEL 8336 HEAT PUMP THERMOSTAT

 

JUMPERED AT THERMOSTAT

 

 

 

 

 

 

 

 

 

 

NOTE 2: W2 TERMINAL ON

R

Y1

O

B

G

E

W2

L

C

Y2

 

HEIL-QUAKER PCB CAPPED

 

 

 

 

 

 

 

 

 

 

BOARD

24 VAC, RETURN

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

COMPRESSOR CONTACTOR

 

 

 

 

 

 

 

 

 

TERMINAL

Y

 

 

 

 

 

 

 

 

 

 

REVERSING VALVE [COOLING MODE]

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

FAN CONTACTOR CIRCUIT

 

 

 

 

 

 

 

 

 

 

VOLTAGE

G

 

 

 

 

 

 

 

 

 

 

2ND. STAGE HEATING CIRCUIT [SEQUENCER 1]

 

 

 

 

 

 

LOW

 

 

 

 

 

 

W1

 

 

 

 

 

 

 

 

 

 

3RD. STAGE HEATING CIRCUIT [SEQUENCER 2]

 

 

 

 

 

 

QUAKER-

 

 

 

 

 

 

W2

 

 

 

 

 

 

 

 

 

 

24 VAC, COMMON

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

HEIL

 

 

 

 

 

 

 

 

 

 

 

THE LOW VOLTAGE TERMINAL DESIGNATIONS AND THEIR DESCRIPTION AND/OR FUNCTION ARE USED ON ALL SPLIT SYSTEM CONDENSORS AND HEAT PUMPS

11

Image 11 Contents
Model Replacing Existing Thermostat FeaturesRemove the cover using a coin or screwdriver Installing the Model 8336 ThermostatMounting Holes Mark placement of mounting holes. See . Set base asideSwitch Or button Changing Temperature DifferentialOperation At the same time and hold for one secondShould turn off Put the COOL-OFF-HEAT-EM switch into the Heat positionTo Test Thermostat Few secondsChanging Fahrenheit F to Celsius C LED IndicatorsTroubleshooting If problems with thermostat cannot be solved, call Aprilaire Model 8336 Heat Pump Thermostat Wiring DiagramsCYC Series Heat Pump Systems Heat Pump Systems Weathertron Lennox LOW Voltage Terminal Board Lennox LOW Voltage Terminal Board Limited Warranty