Hearth and Home Technologies 43M-ACC-MBK, 43ST-ACC Wood Stove Series ACC Firebrick Replacement

Page 34

4300 Wood Stove Series (ACC)

 

 

 

 

 

 

R

 

 

 

 

 

 

 

C. Firebrick Replacement

 

 

 

 

 

 

 

Replace the firebrick if they become crumbly and/or if there

 

1

 

1

 

 

is a 1/4 inch (6.35mm) gap between the bricks.

 

 

 

 

 

 

 

 

 

 

Inspect the firebrick after each ash removal.

 

 

1

 

 

 

1

The firebox is lined with high quality firebrick, which has

 

 

 

 

 

1

1

 

1

1

exceptional insulating properties. There is no need to use a

 

 

 

 

 

3

Grate Location

3

grate; simply build a fire on the firebox floor. Do not operate

 

 

 

 

 

 

 

 

 

 

 

No Brick, ARS

 

 

appliance without firebrick.

 

 

 

 

1

2

2

2

1

1. After the coals have completely cooled, remove all old

 

2

 

 

5

 

 

4

 

 

brick and ash from unit and vacuum firebox.

 

 

 

 

 

 

2. Remove new brick set from box and lay out to diagram

 

6

 

 

 

 

 

shown.

 

 

 

 

 

 

 

 

 

6

 

3. Lay bottom bricks in unit.

 

 

 

 

 

 

 

 

4.

Install rear bricks on the top of the bottom bricks. Slide

 

9 in.

 

 

7-1/4 in.

 

 

top of bricks under clip on back of firebox wall and push

 

 

 

 

 

 

 

 

 

 

 

 

 

bottom of brick back.

 

 

 

 

2-1/2 in.

 

5

 in.

5. Install side bricks. Slide top of brick under clips on side

 

4

 

 

 

 

 

 

 

 

 

of firebox and push the bottom of the brick until it is flush

 

2 in.

 

9 in.

 

 

with the side of the appliance.

 

 

6-/8 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

1

 

Figure 34.2 - 4300 Step Top Brick Assembly

 

 

 

 

 

 

 

 

1

 

 

 

 

1

 

 

 

 

 

 

 

1

 

1

 

1

1

No.

Brick Size

 

Qty

 

 

 

 

 

 

1

9 x 4-1/2 x 1-1/4

 

 

10

 

 

 

1

 

1

 

 

 

 

 

 

 

 

2

6 x 4-1/2

 

 

 

4

 

1

 

 

 

1

 

 

 

 

 

 

2

 

 

3

4-1/2 x 4-1/2 x 1-1/4

 

 

2

 

4

2

2

2

 

 

 

 

 

 

 

3

 

4

9 x 4-1/2 with angles

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

5

9 x 3 with angle

 

 

1

 

 

 

 

 

 

6

9 x 2 x 1-1/4

 

 

 

2

 

 

 

 

 

5

 

 

 

 

 

9 in.

 

 

 

7-1/4 in.

 

Use Part 832-0550 when ordering individual brick. Provide brick

 

 

 

2-1/2 in.

 

 

 

dimension or copy this page, mark the desired brick and take it

 

3

 

 

4

 in.

to your authorized dealer.

 

 

 

 

 

 

 

 

 

 

 

 

 

2 in.

 

9 in.

 

 

 

 

 

 

 

 

6-/8 in.

 

 

 

 

NOTE: The Ash Removal System is only

 

 

 

 

 

 

 

 

 

 

 

 

 

available for the Step Top Model and not

 

 

 

 

 

 

 

for the Millennium Model.

 

Figure 34.1 - 4300 Millennium Top Brick Assembly

 

 

 

 

 

 

No.

Brick Size

19 x 4-1/2 x 1-1/4

2 6 x 4-1/2

39 x 4-1/2 with angles

49 x 3 with angle

59 x 2 x 1-1/4

Qty

12

4

1

1

2

Page 34

7037-135E

September 1, 2008

Image 34
Contents 7037-135E September 1 Step Top Uni-Body Model Millennium ModelHot glass will cause burns Pedestal Model ShownWood Stove Series ACC Mfg. Date 7037-135E September 1Table of Contents Listing and Code Approvals Appliance Certification BTU & Efficiency SpecificationsGlass Specifications Mobile Home ApprovedFire Safety Getting StartedAppliance needs to draft properly for safety Wood Stove Series ACC Negative PressureTools And Supplies Needed Wood Stove Series ACC Flue Draft ConsiderationsVenting Systems Inspect Appliance & Components and Pre-Use Check ListWood Stove Series ACC Typical Stove Systems Masonry ChimneyAppliance Dimensions Dimensions and ClearancesMillennium Model 11/16 in mm 89mm Back of Stove to Glass 25-/8 645mm 10-/8 11/16170mm 264mmInstallation 90 Elbow Off Top of Stove Through Backwall Wood Stove Series ACC Clearances to Combustibles UL and ULCHearth Protection Requirements InstallationWood Stove Series ACC 4300 Millennium ModelWood Stove Series ACC Step-Top Uni-Body Model Items Needed for Installation not supplied Wood Stove Series ACC Outside Air Kit InstallationFire Risk Asphyxiation Risk Wood Stove Series ACC Blower Optional Shock RiskVenting Components Chimney Systems Chimney ConnectorChimney Requirements ThimbleInstructions ComponentsAir Clearances Solid Pack Chimney with Metal Supports as a ThimbleSolid Pack Chimney with Metal Supports as a Thimble Cont’d Installing Chimney ComponentsChimney Height / Rise and Run Pitched Roof Wood Stove Series ACC Chimney Termination RequirementsRule Flat RoofMobile Home Installation Appliance Set Up Begin installing the ARS SystemSlip wooden decorative strips onto pedestal edges Installing Pedestal AssemblyFinishing the ARS Installation Front cut bricks. FigureInstalling Leg Kit Corners. FigureWood Stove Series ACC Door Handle Assembly Adjusting The Blower Speed ControlBurning Process Operating InstructionsOver-Firing Your Appliance Wood Selection & Storage Cont’d Wood Selection & StorageAutomatic Combustion Control ACC Air ControlsBurn Rates and Operating Efficiency Wood Stove Series ACC Building a Fire Correct Position Wood Stove Series ACC Blower Operating Instructions Frequently Asked Questions Opacity SmokeInitial cold start-up and all Burn Settings Snap Disc LocationCreosote Chimney Cleaning General MaintenanceAsh Removal System ARS Operating and Cleaning Maintaining & Servicing Your ApplianceWhen cleaning glass Glass Cleaning Frequency As desiredCleaning Plated Surfaces Disposal of AshesWood Stove Series ACC Glass Replacement For the Millennium Model Wood Stove Series ACC Firebrick ReplacementAvailable for the Step Top Model and not To your authorized dealerWood Stove Series ACC Baffle Removal Snap Disc Replacement Snap Disc LocationRemoving Tube Channel Assembly Wood Stove Series ACC Tube Channel Assembly ReplacementReplacing Tube Channel Assembly Troubleshooting Start Fire Problems Possible Cause SolutionExploded view Reference MaterialsDescription #33 Baffle Board 2 w x 15-3/4 h, each #29 Ceramic Blanket 19 w x 13-3/4 h, 1/2 thickStep-Top Uni-Body Model Door, Cast not sold separatelyWood Stove Series ACC Service Parts & Accessories Blower AssemblyItem # Service Parts Item # Service Parts Wood Stove Series ACC Service And Maintenance Log Date of Service Performed By Description of ServiceWood Stove Series ACC Homeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability September 1 7037-135E Contact Information

43M-ACC-MBK, 43ST-ACC specifications

Hearth and Home Technologies has long been a leader in the design and manufacturing of high-quality heating appliances, and their models 43ST-ACC and 43M-ACC-MBK are no exception. These gas fireplaces combine aesthetic appeal with innovative technologies aimed at providing efficient heating solutions for residential spaces.

The 43ST-ACC is designed with versatility in mind. It features a traditional style that can seamlessly integrate into a variety of home decors. One of its standout characteristics is the expansive viewing area that allows homeowners to enjoy the mesmerizing flames. The fireplace utilizes advanced ceramic glass technology that enhances the thermal efficiency, ensuring a warm environment without compromising on safety.

On the technical side, the 43ST-ACC is equipped with the IntelliFire ignition system which provides convenient, reliable startup. This system also allows for enhanced safety features, ensuring the unit operates smoothly and safely. The adjustable flame height and heat output settings further allow users to create their desired ambiance while optimizing fuel consumption.

Additionally, the 43M-ACC-MBK model is geared towards those who appreciate a modern, sophisticated design. This model is characterized by its sleek, black finish and clean lines, making it an eye-catching centerpiece in any room. Like the 43ST-ACC, it also boasts an impressive viewing area, but it comes with the added benefit of customizable features, including remote control operation and programmable thermostats.

Both models are designed with efficiency in mind, incorporating technology that maximizes heat distribution throughout the room. Their direct vent operation ensures that combustion gases are exhausted outside, making them a safe choice for indoor spaces. The inclusion of a blower system in both models enhances air circulation, providing an even distribution of warmth throughout the environment.

In conclusion, the Hearth and Home Technologies 43ST-ACC and 43M-ACC-MBK gas fireplaces combine style, functionality, and advanced technology. Whether you are looking for a traditional touch or a modern flair, these models cater to diverse preferences while ensuring efficient heating and safety. With their innovative features and beautiful designs, they truly represent the pinnacle of home heating solutions. Whether settling in for a cozy evening or entertaining guests, these fireplaces are sure to enhance any living space.