Contents
SVC MANUALGeneral
Contents
Part 1 General Information
Safety Precautions Nomenclature
Be sure not to do Be sure to follow the instruction
Safety Precautions
Part 1 General Information
Inspections after Repair
Global Model Name
Nomenclature
Code Type Code of Model Meaning
Part 2 Functions & Controls
Function Description
Part 2 Functions & Controls
Cooling Mode
Basic Mode Controls
Heating Mode
Auto changeover operation
Intake air Temp Setting Temp
Healthy Dehumidification operation
Automatic operation
Jet Heat operation
Special Mode Controls
Energy saving operation in cooling mode
Jet Cool operation
Forced operation
Auto cleaning operation
Indoor temp Operating Mode Setting temp
Utility Functions
Natural Air ControlAuto Wind
Air volume control
Chaos Swing
Auto restart
Sleep mode Auto control
Sleep timer operation for cooling cycle
Sleep timer operation for heating cycle
Hot start
Protection Functions & Controls
Five Seconds Stand-by fan
Two Minutes Stand-by comp
1 9,12kBtu/h Model
Automatic defrost
2 18,24,30kBtu/h Model
Starting to the defrosting operation
Control algorithm of defrost completion
Defrosting Control Algorithm
Inverter
Power Relay Control
Overheating Protection Power Module
Heat sink temperature control
Heat sink sensor failure error
Function
CT1 control
Total Current Control Over Current Protection
CT2 control
Model Cooling Heating KBtu/h 18~30 11A 12A 14A
Discharge Pipe Temp Control
DC Peak control
Inverter Compressor 18,24,30kBtu/h Model
There can be two situations
Constant Compressor only 30kBtu/h Model
Compressor working
12.1 9,12kBtu/h Model
Low Ambient control
12.2 18, 24, 30kBtu/h Model
Operation Process
Oil return control30kBtu/h Model
Oil equalizing control30kBtu/h Model
Operating Contion
Part 3 Test Run
Check before Test Run Test Run Flow chart Test Run Detail
Check before Test Run
Start
Test Run Flow chart
Evaluation of the performance
Pump Down Procedure
Test Run Detail
Settlement of outdoor unit
Part 4 Trouble Shooting
Way Valve Liquid Side
Way, 3-Way Valve
Set the 2-way valve to the closed position
Procedure
Pumping Down
Air purging of the charge hose
Evacuation All amount of refrigerant leaked
Purge the air from the charge hose
Mount the valve stem nuts and the service port nut
Gas Charging After Evacuation
Connect the charge hose to the charging cylinder
Trouble analysis
Cycle Troubleshooting Guide
Part 4 Trouble Shooting
Procedure Specification Remedy
Electronic Parts Troubleshooting Guide
Trouble
Compressor/Outdoor Fan dont operate 9~30kBtu/h Model
Compressor/Outdoor Fan dont operate 18, 24, 30kBtu/h Model
When indoor Fan does not operate.9~30kBtu/h Model
Self-diagnosis Function
Error Indicator
12kBtu/h Model
Red Green Status
18,24,30kBtu/h Model Indoor Error
Outdoor Error
Error code Descrition
Part Trouble Shooting
Troubleshooting Guide9,12kBtu/h Model
Description Cause of error Heat-sink Temp. is over
Earth port
DC Peak Error
Description Cause of error Over current Error
Description Cause of error Indoor fan is locked
Description Cause of error Pipe TH. is short or
Check Point
Troubleshooting CH01, CH02, CH06
Troubleshooting CH05, CH53
Part 4 Trouble Shooting
Comp
Troubleshooting CH21
Copper Comp pipe
Troubleshooting CH21, CH22
Troubleshooting CH23, CH28
Troubleshooting CH24, CH25
Troubleshooting CH26, CH27
Troubleshooting CH32, CH33, CH40
Troubleshooting CH41, CH44, CH45, CH46, CH47, CH65
Troubleshooting CH51, CH60
Troubleshooting CH61, CH62
No MFL41161601 August