Auto clean (Optional)

AUTO CLEAN

NOTICE

1.Whenever you press the AUTO CLEAN button, Auto Clean Function will be reserved and cancelled.

2.Auto Clean function works before and after cooling or dehumidification mode. For details, refer to the below points.

3.When the unit is started after the reservation of Auto Clean ,the Cool Start function operates and indoor Fan is started after 20 seconds.

4.When you press Start/Stop button to turn off the unit after the you have reserved Auto Clean function, the air-conditioner circulates the indoor air in the Auto Clean mode with no more Cooling or Dehumidification operation. It lasts for 30 minutes.

5.If you press the AUTO CLEAN button again during the product operation , Auto Clean function will be cancelled.

During Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy Dehumidification Operation can be removed.

During Auto Clean function, only Start/Stop button, Plasma button and AUTO CLEAN button are available.

Forced operation

Operation procedures when the remote control can't be used.

The operation will be started if the ON/OFF button is pressed.

If you want to stop operation, re-press the button.

 

 

 

ON/OFF

 

 

 

 

button

 

 

 

 

 

 

 

Cooling Model

 

Heat pump Model

 

 

 

 

 

 

 

 

Room Temp. 24°C(75.2°F)

21°C(69.8°F) Room Temp. < 24°C(75.2°F)

 

Room Temp. < 21°C(69.8°F)

 

 

 

 

 

 

 

 

 

Operating mode

Cooling

Cooling

Healthy Dehumidification

 

Heating

 

 

 

 

 

 

Indoor FAN Speed

High

High

High

 

High

 

 

 

 

 

 

Setting Temperature

22°C(71.6°F)

22°C(71.6°F)

23°C(73.4°F)

 

24°C(75.2°F)

 

 

 

 

 

 

Test operation

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes.

During test operation, if remote controller signal is received, the unit operates as remote controller sets.

If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1 "beep".

If you want to stop the operation, re-press the button.

24Room Air Conditioner

Image 24
Contents Room Air Conditioner Table of Contents Safety Precautions Be sure not to do Be sure to follow the instructionThere is risk of fire or electric shock There is risk of electric shockExplosion, or injury Damage to the product Edges Could cause personal injury Personal injuryShock There is risk of fire or product failure Oxygen deficiency could occurThere is risk of explosion or fire There is risk of electrical shockIt may cause a problem for your neighbors There is risk of fire or electrical shockBad connection may cause water leakage To avoid vibration or water leakageAvoid personal injury This could damage your healthProduct There is risk of personal injuryBe careful and avoid personal injury There is risk of fire or explosionThey may burn or explode Service Prior To OperationPreparing For Operation UsageSymbols Used In This Manual FeaturesIntroduction IndoorElectrical Safety Operating Instruction Remote Control Operations ControlsCooling operation Gentle Breeze by the Chaos logicAuto operation Optional During Auto OperationAuto changeover operationOptional During Auto Changeover OperationFan speed mode is shifted Healthy dehumidification operationDuring Healthy Dehumidification Operation Close the door of the remote controller Temperature can be set within a rangeRemote controller still closed. You can Heating operation Heat pump model onlyJet cool operation NEO Plasma purification operationOptional NEO Plasma Air Purifying Operation only2nd F operation Button is pressed againAdditional Features Sleep modeSetting the time Delay start/Pre-set stopAdjust the left/right airflow direction by hand Vertical Airflow Direction ControlAuto clean Optional Forced operationTest operation 22C71.6F 23C73.4F 24C75.2FTo disable function To enable functionAuto restart Helpful informationMaintenance And Service Indoor UnitOutdoor Unit Air conditioner is operating normally whenTroubleshooting Air conditioner may be operating abnormally whenAir conditioner does not start Air conditioner does not cool as it should
Related manuals
Manual 27 pages 36.57 Kb Manual 29 pages 29.82 Kb

EN 61000-3, EN 61000-2 specifications

LG Electronics is committed to delivering cutting-edge technology while ensuring compliance with international standards. Among these standards are the EN 61000-2 and EN 61000-3 norms, which address electromagnetic compatibility (EMC) and are critical in defining how electrical and electronic devices interact with their electromagnetic environment.

EN 61000-2 focuses on the environment within which devices operate. This standard outlines the general requirements for the compatibility of various electrical devices in residential, commercial, and industrial environments. It specifies the necessary electromagnetic interference (EMI) levels to protect devices from disturbances that could impact their functionality. For LG Electronics, adherence to EN 61000-2 means engineering products that minimize the potential for EMI disruptions, thereby ensuring reliable performance in diverse settings.

On the other hand, EN 61000-3 addresses the emission limits for harmonic currents in electrical systems and equipment. It focuses on ensuring that devices do not generate excessive current harmonics that could disrupt the normal operation of other equipment. For LG, compliance with EN 61000-3 involves implementing technologies that reduce harmonic distortion, which improves the overall power quality in electrical systems. This aspect is particularly important for ensuring energy efficiency and enhancing the longevity of both LG products and the systems they are integrated into.

One of the main features of LG’s products that adhere to these standards is the incorporation of advanced filtering technologies. These filters are designed to suppress harmful electromagnetic emissions and ensure that devices operate within permissible limits. Furthermore, LG employs superior circuit designs that prioritize efficient power management, helping to minimize harmonic generation.

Moreover, LG’s commitment to sustainability is reflected in its adherence to these norms. By reducing electromagnetic emissions and improving power quality, LG Electronics not only complies with regulations but also contributes to a greener environment. This aligns with the company’s broader vision of producing environmentally friendly and energy-efficient products.

In summary, LG Electronics continuously invests in technologies that ensure compliance with EN 61000-2 and EN 61000-3 norms. Through advanced filtering solutions and efficient circuit designs, the company demonstrates its dedication to electromagnetic compatibility, reliability, and sustainability, reinforcing its position as a leader in the global electronics market.