Sears 139.53930D To Add, Reprogram or Change a Keyless Entry PIN, To set a temporary PIN

Page 36

To Add, Reprogram or Change a Keyless Entry PIN

NOTE: Your new Keyless Entry must be programmed to operate your garage door opener,

USING THE "LEARN" BUTTON

)

1.Press and release the "learn" button on motor unit. The learn indicator

light will glow steadily for 30 seconds.

2.Within 30 seconds, enter a four digit personal identification number (PIN) of your choice on the keypad. Then press and hold the ENTER button.

3.Release the button when the motor unit lights blink. It has learned the

code. If light bulbs are not installed, two clicks will be heard.

To change an existing, known PIN

If the existing PIN is known, it may be changed by one person without using a ladder.

1.Press the four buttons for the present PIN, then press and hold the # button.

The opener light will blink twice. Release the # button.

2.Press the new 4-digit PIN you have chosen, then press Enter.

The motor unit lights will blink once when the PIN has been learned.

Test by pressing the new PIN, then press Enter. The door should move.

To set a temporary PIN

You may authorize access by visitors or service people with a temporary 4-digit PIN. After a programmed number of hours or number of accesses, this temporary PIN expires and will no longer open the door. It can be used to close the door even after it has expired. To set a temporary PIN:

1.Press the four buttons for your personal entry PIN (not the last temporary PIN), then press and hold the _= button.

The opener light will blink three times. Release the button.

2.Press the temporary 4-digit PIN you have chosen, then press Enter.

The opener light will blink four times.

3.To set the number of hours this temporary PIN will work, press the number of hours (up to 255), then press _.

OR

3.To set the number of times this temporary PIN will work, press the number of times (up to 255), then press #.

The opener light will blink once when the temporary PIN has been learned.

Test by pressing the four buttons for the temporary PIN, then press Enter. The door should move. If the temporary PIN was set to a certain number of openings, remember that the test has used up one opening.To clear the temporary password, repeat steps 1-3, setting the number of hours or times to 0 in step 3.

One Button Close: Opener can be closed by pressing only the ENTER button if the one button close feature has been activated. This feature has been activated at the

factory. To activate or deactivate this feature press and hold buttons 1 and 9 for 10 seconds. The keypad will blink twice when the one button close is active. The keypad will blink four times when one button close is deactivated.

36

Image 36 Contents
315N= Garage Door Opener Abridor DE Puerta DE Cochera 315.= Contents IntroductionTools needed Preparing your garage doorSectional Door Installation Sectional Door InstallationsPlanning ONE-PIECE Door Installations ONE-PIECE Door Without TrackONE-PIECE Door with Track Carton Inventory Secu RITY,IAssembly Hardware Installation HardwareHardware Inventory Assembly Step Assemble the Rail & Install the TrolleyInstall the Idler Pulley Fasten the Rail to the Motor UnitInstall the Chain/Cable Installation Readand Followall Installationwarnings and InstructionsTighten Chain Installation Step Determine the Header Bracket LocationInstall the Header Bracket Wall Header Bracket InstallationCeiling Header Bracket Installation Attach the Rail to the Header Bracket Position the Opener Sectional Door or ONE-PIECE Door with TrackHang the Opener Finished CeilingInstall the Door Control Until the sensor beam is connected and properly alignedInstall the Light Attach the Emergency Release Rope and HandleElectrical Requirements Install The Protector System Important Information about the Safety Reversing SensorInstalling the Brackets Garage door track installation preferredWall installation Floor installation FigureAligning the Safety Reversing Sensors Troubleshooting the Safety Reversing SensorsSensors Fasten the Door Bracket StepSectional Doors ONE-PIECEDOORS Connect Door Arm to Trolley Sectional Doors onlyAdjustment procedures, Figure ALL ONE-PIECE DoorsAssemble the door arm, Figure Connect the door arm to the trolleyAdjustment Step Adjust the UP and Down Travel LimitsIf door does not open at least 5 feet 1.5 m If the door does not close completelyAdjust the Force HOW and When to Adjust the ForcesTest the Down close force Test the Safety Reversal System AdjustImportant Safety Check Test The Protector SystemUsing Your Garage Door Opener OperationReadand Followall Warningsand Instructions No Oneshouldgoundera STOPPED,PARTIALLY OpeneddoorUsing the Wall.Mounted Door Control To Open the Door ManuallyDisconnect the Trolley To RE-CONNECT the Trolley Adjustments Remote Control Battery Care of Your Garage Door Opener Having a PROBLEM? Refer to Adjustment , Adjust the ForceSymptom LED is not fit on door control Symptom Motor unit doesnt operateTo Add or Reprogram a Hand.held Remote Control Using the Learn ButtonProgramming To Erase All Codes From Motor Unit MemoryTo Add, Reprogram or Change a Keyless Entry PIN To change an existing, known PINTo set a temporary PIN Repair Parts Rail Assembly PartsInstallation Parts KEY Part DescriptionMotor Unit Assembly Parts KEY Part NO. noKEY Part Description Accessories Warranty