Sears 139.53930D owner manual Aligning the Safety Reversing Sensors

Page 22

MOUNTING AND WIRING THE SAFETY REVERSING Figure 5

SENSORS

Slide a 1/4"-20xl/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension (Figure 5).

Finger tighten the wing nuts.

Run the wires from both sensors to the opener. Use insulated staples to secure wire to wall and ceiling.

Strip 7/16" (11 mm) of insulation from each set of wires. Separate white and white/black wires sufficiently to connect to the opener quick-connect terminals. Twist like colored wires together. Insert wires into quick- connect holes: white to white and white/black to grey (Figure 6).

ALIGNING THE SAFETY REVERSING SENSORS

Plug in the opener. The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct.

The sending eye amber indicator light will glow regardless of alignment or obstruction. If the green indicator light in the receiving eye is off, dim, or flickering (and the invisible light beam path is not obstructed), alignment is required.

Loosen the sending eye wing nut and readjust, aiming directly at the receiving eye. Lock in place.

Loosen the receiving eye wing nut and adjust sensor until it receives the sender's beam. When the green indicator light glows steadily, tighten the wing nut.

Figure 6

Wing Nut 1/4"-20

Carriage Bolt --_

1/4"-20xl/2"

"Lens

TROUBLESHOOTING THE SAFETY REVERSING SENSORS

1.If the sending eye indicator light does not glow steadily after installation, check for:

Electric power to the opener.

A short in the white or white/black wires. These can occur at staples, or at opener connections.

Incorrect wiring between sensors and opener.

A broken wire.

2.If the sending eye indicator light glows steadily but the receiving eye indicator light doesn't:

Check alignment.

Check for an open wire to the receiving eye.

3.If the receiving eye indicator light is dim, realign either sensor.

NOTE: When the invisible beam path is obstructed or misaligned while the door is closing, the door will reverse. If the door is already open, it will not close. The opener lights will blink 10 times. See page 20.

Bell Wire

Bell Wire

l

 

1. Strip wire 7/16"

(11 mm)

7,16" (11 m41)

2. Twist like colored wires together

3. Insert into appropriate terminals

 

 

 

/

Red White

Grey

 

 

 

/

 

 

 

Invisible

Light Beam

Safety Reversing

Quick-Connect

Terminals

 

Sensor

 

 

 

 

 

Safety Reversing

Protection

Area

 

 

 

Sensor

 

 

 

 

 

22

Image 22 Contents
315N= Garage Door Opener Abridor DE Puerta DE Cochera 315.= Contents IntroductionTools needed Preparing your garage doorSectional Door Installations Sectional Door InstallationPlanning ONE-PIECE Door Without Track ONE-PIECE Door InstallationsONE-PIECE Door with Track Carton Inventory Secu RITY,IInstallation Hardware Assembly HardwareHardware Inventory Assembly Step Assemble the Rail & Install the TrolleyInstall the Idler Pulley Fasten the Rail to the Motor UnitInstall the Chain/Cable Readand Followall Installationwarnings and Instructions InstallationTighten Chain Installation Step Determine the Header Bracket LocationWall Header Bracket Installation Install the Header BracketCeiling Header Bracket Installation Attach the Rail to the Header Bracket Position the Opener Sectional Door or ONE-PIECE Door with TrackHang the Opener Finished CeilingInstall the Door Control Until the sensor beam is connected and properly aligned Install the Light Attach the Emergency Release Rope and HandleElectrical Requirements Install The Protector System Important Information about the Safety Reversing SensorWall installation Installing the BracketsGarage door track installation preferred Floor installation FigureTroubleshooting the Safety Reversing Sensors Aligning the Safety Reversing SensorsSensors Step Fasten the Door BracketSectional Doors ONE-PIECEDOORS Connect Door Arm to Trolley Sectional Doors onlyAssemble the door arm, Figure Adjustment procedures, FigureALL ONE-PIECE Doors Connect the door arm to the trolleyIf door does not open at least 5 feet 1.5 m Adjustment StepAdjust the UP and Down Travel Limits If the door does not close completelyHOW and When to Adjust the Forces Adjust the ForceTest the Down close force Important Safety Check Test the Safety Reversal SystemAdjust Test The Protector SystemReadand Followall Warningsand Instructions Using Your Garage Door OpenerOperation No Oneshouldgoundera STOPPED,PARTIALLY OpeneddoorDisconnect the Trolley Using the Wall.Mounted DoorControl To Open the Door Manually To RE-CONNECT the TrolleyRemote Control Battery AdjustmentsCare of Your Garage Door Opener Having a PROBLEM? Refer to Adjustment , Adjust the ForceSymptom LED is not fit on door control Symptom Motor unit doesnt operateProgramming To Add or Reprogram a Hand.held Remote ControlUsing the Learn Button To Erase All Codes From Motor Unit MemoryTo change an existing, known PIN To Add, Reprogram or Change a Keyless Entry PINTo set a temporary PIN Installation Parts Repair PartsRail Assembly Parts KEY Part DescriptionKEY Part NO. no Motor Unit Assembly PartsKEY Part Description Accessories Warranty