State Industries XCVIT What to do if YOU Smell GAS, Do not TRY to Light the Burner by Hand

Page 13

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or

explosion may result causing property damage, personal injury or loss of life.

BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES.

A.This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do NOT try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch;

do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in the gas control buttons. Never use tools. If the control buttons will not push in, don’t try to repair them, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately contact a qualified installer or service agency to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above, on this label.

2.Set the thermostat to the lowest setting by first

pressing the COOLER and HOTTER buttons together and holding for 1 second. Then press the

COOLER button until the WARM indicator light appears.

3.Turn the “ON/OFF” switch on the blower control box to the “OFF” position.

4.This appliance is equipped with a device which automatically lights the burner.

DO NOT TRY TO LIGHT THE BURNER BY HAND.

5. Wait five (5) minutes to

clear out any gas.

If you then smell gas,

STOP! Follow “B”

in the safety information above on this label. If you don’t smell gas, go to the next step.

6.Turn on all electrical power to the appliance.

7.Set thermostat to desired setting by first pressing

the COOLER and HOTTER buttons together and holding for 1 second. Then press the HOTTER button.

8.If the appliance will not operate, follow the instructions “TO TURN OFF GAS TO APPLIANCE” and call your technician or gas supplier.

9.WATER TEMPERATURE ADJUSTMENT

is approximately 120°F.

CAUTION: Hotter water increases the risk of scald injury. Consult the instruction manual before changing temperature.

WARNING: TURN OFFALL ELECTRIC

POWER BEFORE SERVICING

TO TURN OFF GAS TO APPLIANCE

1.Set thermostat to the lowest setting by first pressing the COOLER and HOTTER buttons together

and holding for 1 second. Then press the COOLER button until the WARM indicator light appears.

2.Set the ON/OFF switch on the blower control box to the “OFF” position.

3.Turn off all electric power to the appliance if service is to be performed.

13

Image 13
Contents Residential GAS Water Heaters With HOT Surface Ignition Or 3 PVC Vent Capability Replacement Parts and Deliming ProductsChemical Vapor Corrosion External DamageImproper Combustion Liquid Petroleum ModelsRequired Ability High Altitude InstallationGeneral GroundingWater Potable Heating and Space Water ConnectionsClosed Water System GAS ConnectionsRelief Valve P-FIG Vent Terminal InstallationVenting Vent Pipe TerminationVent Hoods MAY be Extremely HOT During Operation Sequence of InstallationPage Maximum Pipe Installation of Vent System Vertical Vent Termination Restrictions Vertical Vent Through Roof Vent Pipe Preparation Recommended BRUSH* Size for Primer Filling Cleanup and joint movementDo not TRY to Light the Burner by Hand What to do if YOU Smell GASTemperature Setting C Burns on Adult Skin Temperature RegulationMake sure gas and electric power are connected properly High Temperature Limit SwitchWater Heating Ignition Sequence Main Burner -FIGVenting System Blower Assembly MaintenanceValve CondensationWater Heater Control LED Status Problem Solution Trouble ShootingVent Pipe TOO HOT HOT WaterYellow Flame CondensationClaim Procedure Service and Labor ResponsibilityConditions and Exceptions Limitation on Implied WarrantiesLindahl Parkway Ashland CITY, TN