State Industries PR6 40, CCVIT PR6 50, XCVIT With HOT Surface Ignition Or 3 PVC Vent Capability

Page 2

GET TO KNOW YOUR WATER HEATER

REPLACEMENT PARTS AND DELIMING PRODUCTS

Replacement parts and recommended delimer may be ordered through authorized servicers or distributors. Refer to the Yellow Pages for where to call or contact State Water Heaters, 500 Lindahl Parkway, Ashland City, TN 37015. When ordering parts, provide complete model and serial numbers (see rating plate), quantity and name of part desired (as listed in Figure 1). Standard hardware items may be purchased locally.

(A)

VENT PIPE-EXHAUST

(O)

INLET DIP TUBE

(B)

ANODE

(P)

TEMPERATUREAND

(C)

HOT WATER OUTLET

 

PRESSURE RELIEF VALVE

(D)OUTLET (115 VAC) (Q) EMBLEM AND RATING PLATE

(E)

FLUE BAFFLE

(R)

INSULATION

(F)

GAS SUPPLY

(S)

VENT TERMINAL

(G)

MAIN MANUAL GAS

(T)

DRAIN VALVE

 

SHUT OFF VALVE

(U)

HSI BURNER ASSEMBLY

(H)

GROUND JOINT UNION

(V)

FLUE

(J)

DIRT LEG

(W)

DRAIN PAN

(K)

OUTER DOOR

(X)

GAS VALVE

(L)

UNION

(Y)

CONTROL HARNESS

(M)

INLET WATER SHUT

(Z)

INNERDOOR

 

OFF VALVE

(AA) FLOOR DRAIN

(N)

COLD WATER INLET

(BB) VENTADAPTER

*CAUTION: 115VAC IN CONTROL HARNESS AND INSIDE OUTER DOOR

GAS MODELS

WITH HOT SURFACE IGNITION

FIGURE 1

& - 2” OR 3” PVC VENT CAPABILITY

NATURAL HOT SURFACE IGNITER & MAIN BURNER

HOT

SURFACE

IGNITOR

SENSOR

PROPANE HOT SURFACE IGNITER & MAIN BURNER

HOT

SURFACE

IGNITOR

SENSOR

TEMPERATURE INDICATORS

TEMPERATURE ADJUSTMENT BUTTONS

2

Image 2
Contents Residential GAS Water Heaters Replacement Parts and Deliming Products With HOT Surface Ignition Or 3 PVC Vent CapabilityImproper Combustion External DamageChemical Vapor Corrosion Liquid Petroleum ModelsGeneral High Altitude InstallationRequired Ability GroundingClosed Water System Water ConnectionsWater Potable Heating and Space GAS ConnectionsVenting Vent Terminal InstallationRelief Valve P-FIG Vent Pipe TerminationSequence of Installation Vent Hoods MAY be Extremely HOT During OperationPage Installation of Vent System Maximum PipeVent Pipe Preparation Vertical Vent Through RoofVertical Vent Termination Restrictions Recommended BRUSH* Size for Primer Cleanup and joint movement FillingWhat to do if YOU Smell GAS Do not TRY to Light the Burner by HandTemperature Regulation Temperature Setting C Burns on Adult SkinWater Heating Ignition Sequence High Temperature Limit SwitchMake sure gas and electric power are connected properly Main Burner -FIGValve Blower Assembly MaintenanceVenting System CondensationTrouble Shooting Water Heater Control LED Status Problem SolutionYellow Flame HOT WaterVent Pipe TOO HOT CondensationConditions and Exceptions Service and Labor ResponsibilityClaim Procedure Limitation on Implied WarrantiesLindahl Parkway Ashland CITY, TN