TEMPERATURE REGULATION

Due to the nature of the typical water heater, the water temperature in certain situations may vary up to 30°F (16.7 °C) higher or lower at the point of use such as, bathtubs, showers, sink, etc.

Any water heater’s intended purpose is to heat water. Hot water is needed for cleansing, cleaning, and sanitizing (bodies, dishes, clothing). Untempered hot water can present a scald hazard. Depending on the time element, and the people involved (adults, children, elderly, infirm, etc.) scalding may occur at different temperatures.

HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve, shall be used at the hot water taps used by these people or at the water heater. Mixing valves are available from your local plumbing contractor. Follow manufacturer’s instructions for installation of the valves. Before changing the factory setting on the thermostat, read the “Temperature Regulation” section in this manual.

THIS WATER HEATER IS EQUIPPED WITH AN ADJUSTABLE THERMOSTAT TO CONTROL WATER TEMPERATURE. HOT WATER TEMPERATURES DESIRED FOR AUTOMATIC DISHWASHERANDLAUNDRYUSECANCAUSESCALDSRESULTING IN SERIOUS PERSONAL INJURY AND/OR DEATH. THE TEMPERATURE AT WHICH INJURY OCCURS VARIES WITH THE PERSON’S AGE AND THE TIME OF THE EXPOSURE. THE SLOWER RESPONSE TIME OF CHILDREN, AGED OR DISABLED PERSONS INCREASES THE HAZARDS TO THEM. NEVER ALLOW SMALL CHILDREN TO USE A HOT WATER TAP, OR TO DRAW THEIR OWN BATH WATER. NEVER LEAVE A CHILD OR DISABLED PERSON UNATTENDEDINABATHTUBORSHOWER.

It is recommended that lower water temperatures be used to avoid the risk of scalding. It is further recommended, in all cases, that the water temperature thermostat be set for the lowest temperature which satisfies your hot water needs, see Figure 11. This will also provide the most energy efficient operation of the water heater. The Thermostat has been factory set between LO an HI which approximates 120°F (49°C) unless specified differently by state requirements.

KEEPINGTHETHERMOSTATSETTINGAT120°F(49°C)WILLREDUCE THE RISK OF SCALDS.

Figure 11 shows the approximate time-to-burn relationship for normal adult skin.

TEMPERATURE ADJUSTMENT

To change the temperature setting:

NOTE:

1.Turn off the heater electrical supply. Do not attempt to adjust thermostat with power on.

2.Remove the thermostat outer door and fold away the insulation from the thermostat. Do not remove the plastic personnel protector covering the thermostat.

3.Using a flat tip screwdriver, rotate the adjustment knob to the desired temperature setting.

4.Fold the insulation back in place, replace the outer door and turn on heater electrical supply.

LO - Setting, approximately 95°F (35°C) is recommended for vacations or extended periods of no hot water.

HI - Is setting for the maximum hot water usage approximately 140°F (60°C), which can be supplied by the water heater.

TEMPERATURE SETTINGS

It is recommended that the dial be set lower whenever possible.

Temperature

 

Time to Produce 2nd & 3rd

Setting

 

Degree Burns on Adult Skin

 

 

 

160°F (71°C)

 

About 1/2 second

150°F (66°C)

 

About 1-1/2 seconds

140°F (60°C)

 

Less than 5 seconds

130°F (54°C)

 

About 30 seconds

120°F (49°C)

 

More than 5 minutes

 

 

 

 

FIGURE 11.

12

Image 12
Contents Residential Point of USE Electric Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionTypical Installation Mixing Valve UsageInstalling the NEW Water Heater Locating the NEW Water HeaterFacts to Consider about the Location Insulation BlanketsWater Piping TEMPERATURE-PRESSURE Relief Valve Filling the Water Heater Wiring Diagrams Optional Cord SET Wiring 120 Volt and 240 VoltWiring Temperature Regulation Temperature AdjustmentFor Your Information Operational ConditionsPeriodic Maintenance TEMPERATURE-PRESSURE Relief Valve OperationThermostat Removal / Replacement DrainingElement Cleaning / Replacement Drain Valve Washer Replacement ServiceLeakage Checkpoints Troubleshooting Guidelines Problem Cause SolutionRepair Parts List Point of USE Electric ModelsDrain PAN

184735-000 specifications

State Industries is a prominent manufacturer known for its wide range of high-quality heating and cooling equipment, and the model number 184735-000 is a noteworthy example of its innovative product offerings. This particular model is designed to meet the demands of both residential and commercial settings, providing efficient solutions for temperature control.

One of the main features of the State Industries 184735-000 is its robust construction, ensuring durability and longevity even under the most demanding conditions. The unit is built with corrosion-resistant materials, making it a reliable choice for various environments, whether in humid coastal areas or dry inland regions. This factor significantly enhances its appeal to consumers who prioritize reliability in their heating and cooling systems.

In terms of technology, the 184735-000 incorporates advanced engineering principles that optimize energy efficiency. The unit is designed to adhere to modern energy standards and has potential for energy savings through its innovative compressor design. This technology not only reduces operational costs but also contributes to a reduced carbon footprint, making it an environmentally responsible choice.

The heating element in the State Industries 184735-000 utilizes state-of-the-art heating technology, providing rapid and efficient heating. This is particularly beneficial during colder months, ensuring that indoor spaces maintain a consistent and comfortable temperature. Additionally, it features user-friendly controls that allow for easy temperature adjustments, accommodating the varying preferences of different users.

Another characteristic worth mentioning is the unit's adaptability. The State Industries 184735-000 can be integrated with existing HVAC systems, enabling seamless installation and compatibility with current infrastructure. This aspect is crucial for both homeowners looking to upgrade their systems and businesses seeking to improve energy efficiency without a complete overhaul.

Furthermore, the model comes equipped with comprehensive safety features, including overheat protection and automatic shut-off mechanisms, ensuring safe operation even in the event of an unexpected malfunction. These features not only enhance user confidence but also contribute to the overall longevity of the unit.

In conclusion, the State Industries 184735-000 is designed with a focus on efficiency, durability, and user-friendliness. Its advanced technologies and robust construction make it a valuable asset for anyone seeking reliable heating and cooling solutions. Whether for residential or commercial use, this model stands out as a testament to State Industries' commitment to quality and innovation in the HVAC industry.