State Industries 184735-000 Periodic Maintenance, TEMPERATURE-PRESSURE Relief Valve Operation

Page 14

PERIODIC MAINTENANCE

TEMPERATURE-PRESSURE

RELIEF VALVE OPERATION

The temperature-pressure relief valve must be manually operated at least once a year.

When checking the temperature-pressure relief valve operation, make sure that (1) no one is in front of or around the outlet of the temperature- pressure relief valve discharge line, and (2) that the water discharge will not cause any property damage, as the water may be extremely hot, see Figure 9.

FIGURE 12.

If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions, and replace the temperature-pressure relief valve with a new one.

If the temperature-pressure relief valve on the appliance weeps or discharges periodically, this may be due to thermal expansion. You may have a check valve installed in the water line or a water meter with a check valve. Consult your local water supplier or service agency for further information. Do not plug the temperature-pressure relief valve.

DRAINING

The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary.

1.Turn electrical supply “OFF”.

2.CLOSE the cold water inlet valve to the water heater.

3.OPEN a nearby hot water faucet and leave open to allow for draining.

4.Connect a hose to the drain valve and terminate to an adequate drain.

5.OPEN the water heater drain valve to allow for tank draining.

NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be left open with hose connected allowing water to terminate to an adequate drain.

6.Close the drain valve.

7.Follow the instructions in the “Filling the Water Heater” section.

THERMOSTAT REMOVAL / REPLACEMENT

1.Turn “OFF” the electric power supply to the water heater.

2.Remove the outer door and fold back the insulation.

3.Lift out the tab as shown below to unclip the terminal cover from the thermostat. The terminal cover can now be removed from the thermostat.

FIGURE 13.

14

Image 14
Contents Residential Point of USE Electric Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionTypical Installation Mixing Valve UsageFacts to Consider about the Location Installing the NEW Water HeaterLocating the NEW Water Heater Insulation BlanketsWater Piping TEMPERATURE-PRESSURE Relief Valve Filling the Water Heater Wiring Diagrams Optional Cord SET Wiring 120 Volt and 240 VoltWiring Temperature Regulation Temperature AdjustmentFor Your Information Operational ConditionsThermostat Removal / Replacement Periodic MaintenanceTEMPERATURE-PRESSURE Relief Valve Operation DrainingElement Cleaning / Replacement Drain Valve Washer Replacement ServiceLeakage Checkpoints Troubleshooting Guidelines Problem Cause SolutionDrain PAN Repair Parts ListPoint of USE Electric Models

184735-000 specifications

State Industries is a prominent manufacturer known for its wide range of high-quality heating and cooling equipment, and the model number 184735-000 is a noteworthy example of its innovative product offerings. This particular model is designed to meet the demands of both residential and commercial settings, providing efficient solutions for temperature control.

One of the main features of the State Industries 184735-000 is its robust construction, ensuring durability and longevity even under the most demanding conditions. The unit is built with corrosion-resistant materials, making it a reliable choice for various environments, whether in humid coastal areas or dry inland regions. This factor significantly enhances its appeal to consumers who prioritize reliability in their heating and cooling systems.

In terms of technology, the 184735-000 incorporates advanced engineering principles that optimize energy efficiency. The unit is designed to adhere to modern energy standards and has potential for energy savings through its innovative compressor design. This technology not only reduces operational costs but also contributes to a reduced carbon footprint, making it an environmentally responsible choice.

The heating element in the State Industries 184735-000 utilizes state-of-the-art heating technology, providing rapid and efficient heating. This is particularly beneficial during colder months, ensuring that indoor spaces maintain a consistent and comfortable temperature. Additionally, it features user-friendly controls that allow for easy temperature adjustments, accommodating the varying preferences of different users.

Another characteristic worth mentioning is the unit's adaptability. The State Industries 184735-000 can be integrated with existing HVAC systems, enabling seamless installation and compatibility with current infrastructure. This aspect is crucial for both homeowners looking to upgrade their systems and businesses seeking to improve energy efficiency without a complete overhaul.

Furthermore, the model comes equipped with comprehensive safety features, including overheat protection and automatic shut-off mechanisms, ensuring safe operation even in the event of an unexpected malfunction. These features not only enhance user confidence but also contribute to the overall longevity of the unit.

In conclusion, the State Industries 184735-000 is designed with a focus on efficiency, durability, and user-friendliness. Its advanced technologies and robust construction make it a valuable asset for anyone seeking reliable heating and cooling solutions. Whether for residential or commercial use, this model stands out as a testament to State Industries' commitment to quality and innovation in the HVAC industry.