State Industries 0710 316888-002 Fault Lockout Code Description Cause Remedy Type Displayed

Page 48

If an error code is displayed, or odd behavior of the unit occurs, the first corrective action should be to “Cycle the Power”: Unplug the 120Vac power cord and after 5 seconds plug it in again. If this doesn’t clear the fault, proceed with the “Remedy” in the following table (Table 5).

If wire harness checking is required, examine the integrity of wires themselves, the connector housings, the integrity of the terminals as well as condition of the crimps.

Fault

 

 

Lockout

 

Code

Description

Cause

Remedy

type

Displayed

 

 

 

 

 

 

 

 

 

Control detects that the

 

 

E01, E02

Invalid Rated

configuration selected is not

Continuous

Change the main controller board

KBtu/Model Type.

defined or the configuration

(board).

 

 

has never been set.

 

 

 

 

Control detects that a relay

 

 

E03, E04,

Main Valve Relay

used to enable the Main

Soft

Change the board.

E05, E06

Out Of Sequence.

Valve has failed in either the

 

 

 

 

open or closed position.

 

 

E07

Flame Detected.

Flame detected when no

 

1. Check the flame rod.

 

 

flame was expected.

Soft

2. Check the flame wire harness.

 

 

 

 

3. Change the board.

E08

ECO switch is

Control detects that the

 

1. Measure the water temperature.

 

open.

ECO switch is open,

 

ECO switch open temperature

 

 

preventing power to the

 

is 85±5ºC (185±14ºF) and close

 

 

Main Valve.

Continuous

temperature is 65±5ºC (149±14ºF).

 

 

 

 

2. Check the ECO switch.

 

 

 

 

3. Check the ECO wire harness.

 

 

 

 

4. Change the board.

E09

High temperature

Control detects that the High

 

1. Measure the water temperature.

 

Vent Switch Open.

Temperature Vent Switch is

 

High Vent Switch open temperature

 

 

open, preventing power to

 

is 74±2.8ºC (165±5ºF) and close

 

 

the Main Valve.

Continuous

temperature is 57±2.8ºC (135±5ºF).

 

 

 

2. Check the switch.

 

 

 

 

3. Check the High Vent Switch wire

 

 

 

 

harness.

 

 

 

 

4. Change the board.

E10

120Vac too high.

120Vac > Overvoltage Limit.

 

Nominal voltage is 120Vac.

E11

120Vac too low.

120Vac < Undervoltage

 

Overvoltage limit is 132Vac,

 

 

Limit.

 

Undervoltage limit is 102Vac.

 

 

 

 

1. Check the power cord.

 

 

 

Auto Reset

2. Check the wall outlet.

 

 

 

 

3. Measure the voltage at the board

 

 

 

 

connector J7 between pin1 and pin

 

 

 

 

3. If the voltage is between limits,

 

 

 

 

change the board.

E12

 

Blower Current meets

 

 

 

 

requirements for a

 

 

 

 

completely blocked flue.

 

1. Check the venting system. If the

E13

 

Blower Current meets

 

venting system is clear, recalibrate

 

Blower Current

requirements for a partially

Soft

the unit.

 

abnormal.

blocked flue.

2. Check the blower wire harness.

 

 

 

 

 

 

3. Change the blower.

E14

 

Blower Current meets

 

 

 

requirements for a non-

 

4. Change the board.

 

 

heating blocked flue

 

 

 

 

evaluation.

 

 

 

 

TABLE 5

 

 

48

www.statewaterheaters.com

Image 48
Contents Power Vent GAS Models AN Odorant is Added to the GAS Used By this Water HeaterTable of Contents Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Can be triggered at any time Preparing for the Installation IntroductionPage Replacement Parts and Deliming Products GET to Know Your Water Heater GAS ModelsOperation Installation Considerations Rough in DimensionsDirectly BELOW. Keep Clear of ALL Obstructions Water Piping Mixing Valve Usage Suggested Piping Arrangement For TOP ConnectionsWater Potable Heating All models are considered Hotter Water can ScaldFacts to Consider about Location Handle Installation Earthquake Zones Page Combustion AIR and Ventilation Appliances in Unconfined SpacesAppliances in Confined Spaces ALL AIR from Outdoors See Figures 12, 13 Chemical Vapor Corrosion Water PipingClosed Water Systems Thermal ExpansionTEMPERATURE-PRESSURE Relief Valve Hard WaterValve and Pipe Insulation if supplied GAS Piping High Altitude Installations GAS Line PurgingFLOODING/FREEZING Filling the Water HeaterIf using 2 inch vent pipe Vent Pipe TerminationPlanning the Vent System If using 3 inch vent pipe Installation of Vent System Vent Terminal INSTALLATION, SidewallCondensate Masonry Side WallsSequence of Installations Installation SequenceVent terminals supplied with heater must be used Installation of Vent SYSTEM, Sidewall Installation of Vertical Vent SystemVent Pipe Preparation Initial PreparationSelection of Materials Recommended BRUSH* Size for Primer Cement Applications Step aStep B Power Vent Step EStep F Step G Connection to Vent PipeVent Hoods MAY be Extremely HOT During Operation Electrical Connections Filling the Water HeaterCalibration Operating Instructions Display PanelPage MCU For Your Safety Read Before Lighting Lighting InstructionsHeat Cycle Definitions State Description Temperature Regulation Unique Hybrid Features Temperature ProbesPage Temperature Regulation Constant Output Temperature Control Start UP ConditionsOperational Conditions Maintenance HousekeepingVenting System Inspection Burner Operation and InspectionAnode ROD Replacement TEMPERATURE-PRESSURE Relief Valve OperationCleaning the Inlet Water Filter MotorsCleaning the Heat Engine Flushing the Heat Exchanger Lime BUILD- UPFault Indication and Error Codes Draining the TankDiagnostic Display RemarksCode Display Example Format Fault Lockout Code Description Cause Remedy Type Displayed Fault Lockout Code Description Cause Remedy Type Displayed Fault Lockout Code Description Cause Remedy Type Displayed Troubleshooting When the TAP is Opened There is no HOT Water orHOT Water Turns Cold Stays ColdService Leakage CheckpointsParts Identification Item # Description AB C DEF Replacement Parts Description NIP/DIP/TBO/HTKIT # Service and Labor Responsibility Claim ProcedureConditions and Exceptions Limitation on Implied WarrantiesPage

0710 316888-002, GPH-90N specifications

The State Industries GPH-90N,0710 316888-002 is a high-quality water heater designed to meet the demands of both residential and commercial applications. Renowned for its durability and efficiency, this model serves as an essential component for facilities requiring reliable hot water supply.

One of the standout features of the GPH-90N is its impressive heating capacity, which allows it to deliver hot water quickly and effectively. This model boasts a heating input of 90,000 BTU per hour, making it suitable for large households or commercial establishments. The unit is designed to maintain consistent water temperatures, ensuring that users have access to hot water whenever needed.

The GPH-90N is also equipped with advanced technologies that enhance its operational efficiency. It features a modulating gas burner that adjusts its output to match the flow rate of hot water demanded, thereby optimizing energy use and minimizing operating costs. This technology not only improves performance but also extends the lifespan of the water heater.

Durability is a key characteristic of the State Industries GPH-90N. The unit is crafted from high-quality materials, including a robust stainless steel tank that resists corrosion and ensures long-lasting performance. This corrosion-resistant design is particularly beneficial in areas with hard water, where mineral deposits can be a significant concern. Additionally, the tank is insulated with high-density foam, which helps to maintain heat and reduce standby heat loss.

A crucial aspect of the GPH-90N is its user-friendly features. The control panel is straightforward, allowing users to adjust settings with ease. The water heater is also designed for simple maintenance, ensuring that annual servicing can be carried out with minimal disruption.

Safety is paramount in the design of the GPH-90N. It includes multiple safety features, such as a pressure relief valve and a safety shut-off mechanism, which provide peace of mind for users. This ensures that the unit operates safely under varying conditions.

In conclusion, the State Industries GPH-90N,0710 316888-002 is a powerful and efficient water heater that combines advanced technology with durable construction. Its high heating capacity and user-friendly design make it a reliable choice for both residential and commercial applications, ensuring that hot water is always available when needed.