Graco Inc 260101, 260102, 260104, 260100 important safety instructions Technical Data

Page 10

Technical Data

Technical Data

Maximum Working Pressure

65 psi (0.45 MPa, 4.5 bar)

Automatic Relief Setting

Models 260100, 260101, 260104:

 

65 psi (0.45 MPa, 4.5 bar)

 

Model 260102:

 

30 psi (0.21 MPa, 2.1 bar)

Output Flow

Model 260100: 5.8 gpm (22.0 lpm)

 

Model 260101: 4.25 gpm (16.15 lpm)

 

Model 260102*: 8.0 gpm (30.3 lpm)

 

Model 260104: 4.25 gpm (16.15 lpm)

Inlet Size

1 in. npt

Outlet Size

3/4 in. npt

Weight

Model 260100: 34 lb (15.3 kg)

 

Models 260101, 260102, 260104:

 

25 lb (11.25 kg)

Dimensions

See page 11

Voltage/current

Model 260100: 12 VDC, 35 amps

 

Models 260101, 260102:

 

115 VAC, 60 Hz, 9.2 amps

 

Model 260104: 230 VAC, 50/60 Hz, 4 amps

Power Cord

Model 260101, 260102 only: 30 in. (762 mm)

Hose size

8 ft (2.4 m), 3/4 in. (19 mm) ID

Suction tube

34 in. (864 mm)

Wetted parts

carbon steel with zinc plating, stainless steel,

 

galvanized steel, aluminum, nitrile, rubber, PVC,

 

PVC cement

*Model 260102 is intended for use with fluid viscosities of 1000 centistokes (5000 ssu) or less. For fluids with viscosities greater than 1000 centistokes use pump model 260101.

10

311305E

Image 10
Contents Apex Fire and Explosion Hazard Pressurized Equipment Hazard Mounting Pump on Barrel or Tank InstallationMounting Hose and Nozzle Pressure Relief Procedure Electrical Installation 115 VAC and 230 VACElectrical Installation 12 VDC OperationTroubleshooting Problem Cause SolutionTroubleshooting Parts Description Qty Technical Data Dimensions Models Length a Height B Width CPerformance Chart 311305E Graco Standard Warranty Graco Information